Preparative HPLC

HPLC Therapeutic Peptide Method Development Kit - 176001836
SKU: 176001836
HPLC Therapeutic Peptide Method Development Kit - 176001836
List Price
$1030.00
Category: Sample Preparation & Filtration
HPLC Therapeutic Peptide Method Development Kit - 176001836: The HPLC Therapeutic Peptide Method Development kit simplifies the process of sample preparation and LC method development for the analysis of therapeutic peptides in plasma. The kit contains one 96-well Oasis Peptide μElution Method Development Plate (186004713), one XBridge UPLC 3.5 µm BEH 300 C18 reversed-phase 2.1x50 mm column (186003607), three 96-well 1 mL collection plates and cap mats (600001043), and a detailed screening protocol.
Part Number: 176001836
Brand: Oasis
Application Peptide
Product Type Application Kits
Sep-Pak / HPLC Adapter, Peek, 1 set - JJAN60071
SKU: JJAN60071
Sep-Pak / HPLC Adapter, Peek, 1 set - JJAN60071
Category: Sample Preparation & Filtration
Buy Sep-Pak / HPLC Adapter, Peek, 1 set - JJAN60071 from Waters
Part Number: JJAN60071
Preparative Needle Assembly, 60 µL - 700004085
SKU: 700004085
Preparative Needle Assembly, 60 µL - 700004085
List Price
$505.00
Category: Service Parts & Kits
Preparative Needle Assembly, 60 µL - 700004085: Replacement Preparative Needle assembly (60µL) for the 2707 Autosampler.
Part Number: 700004085
Brand: Waters Quality Parts
Replacement Schedule Annual
System HPLC
Type Needle
Units per Package 1 pk
Flowcell Rebuild Kit, 2998 Semi-Preparative - 700005101
SKU: 700005101
Flowcell Rebuild Kit, 2998 Semi-Preparative - 700005101
List Price
$580.00
Category: Service Parts & Kits
Flowcell Rebuild Kit, 2998 Semi-Preparative - 700005101: This rebuild kit contains the lenses and gaskets necessary to rebuild a 2998 semiprep flow cell.
Part Number: 700005101
Product Type Rebuild Kits
Replacement Schedule As Required
System Type HPLC
Type Rebuild Kit
Units per Package 1 pk
Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 75 mm, 1/pk - 186004712
SKU: 186004712
Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 75 mm, 1/pk - 186004712
List Price
$4095.00
Category: Columns
Atlantis T3 OBD Prep Column, 100Å, 10 µm, 30 mm X 75 mm, 1/pk - 186004712: Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Part Number: 186004712
Brand: Atlantis
Bonding Technology T3
Carbon Load 14 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Pico-Tag Chem Pkg Free AA - WAT091681
SKU: WAT091681
Pico-Tag Chem Pkg Free AA - WAT091681
List Price
$3864.00
Category: Standards & Reagents
Pico-Tag Chem Pkg Free AA - WAT091681: The Waters Pico Tag™ Method has been widely used for amino acid analysis for over two decades. Pico Tag™ Amino Acid Analysis of Physiologic Amino Acids, Free Amino Acid Chemistry All-inclusive Package includes: column WAT010950, reagent kit WAT010947, eluents WAT010960 and WAT010965, diluent WAT088119, manual, column heater inserts and sample tubes.
Part Number: WAT091681
Brand: Pico-Tag
Application Amino Acid Analysis
Detection Method UV
Number of Analysis 250
Packages per kit 1
Product Type Application Kits
Separation Mode HPLC
Storage Room Temperture
Type Sample Preparation Workflow
Units per Package 1 pk
AccQ-Tag Chemistry Kit (250 Analyses) - WAT052875
SKU: WAT052875
AccQ-Tag Chemistry Kit (250 Analyses) - WAT052875
List Price
$2685.00
Category: Application Kits
AccQ-Tag Chemistry Kit (250 Analyses) - WAT052875: Amino Acid Analysis (AAA) is required for many applications. ACCQ-Tag Chemistry Kit for up to 250 Analyses includes: AccQFluor Reagent 1 5 X 6mL vials, AccQFluor Reagent 2A 5 X 3mg vials, AccQFluor Reagent 2B 5 X 3 mL vials, AccQTag Column 3.9 X 150mm, AccQTag Eluent A Concentrate 2 X 1L, Sample tubes 4 X 72/pkg, AminoAcid Standard, Hydrolysate 10 X 1mL Ampules WAT088122, AccQTag User Guide WAT052874
Part Number: WAT052875
Brand: AccQ-Tag
Application Amino Acid Analysis
Detection Method Fluorescence, UV
Number of Analysis 250
Packages per kit 1
Product Type Application Kits
Separation Mode HPLC
Storage Room Temperture
System Type HPLC
Type Sample Preparation Workflow
Units per Package 1 pk
PicoTag Chemistry Package - WAT007360
SKU: WAT007360
PicoTag Chemistry Package - WAT007360
List Price
$2699.10
Category: Standards & Reagents
PicoTag Chemistry Package - WAT007360: The Waters Pico Tag Method has been widely used for amino acid analysis for over two decades. This method is applicable to any sample including protein hydorylasates, physiological fluids, feeds, foods and pharmaceudical preparations. The Pico Tag Chemistry Package is an all-inclusive package that includes: column reagent kit, eluents, diluents, manual, and column heater inserts. In order to perform the Pico.Tag methodology, a Pico.Tag™ workstation is needed. The workstation and parts can be purchased through Eldex by clicking on the following links: Pico.Tag workstation--> http://eldex.com/products/hydrolysis-derivatization-workstation
Part Number: WAT007360
Brand: Pico-Tag
Application Amino Acid Analysis
Detection Method UV
Number of Analysis 250
Packages per kit 1
Product Type Application Kits
Separation Mode HPLC
Storage Room Temperture
Type Sample Preparation Workflow
Units per Package 1 pk
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 250 mm, 1/pk - 186007314
SKU: 186007314
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 250 mm, 1/pk - 186007314
List Price
$3915.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 250 mm, 1/pk - 186007314: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007314
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pk - 186007313
SKU: 186007313
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pk - 186007313
List Price
$3275.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pk - 186007313: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007313
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 100 mm, 1/pk - 186007318
SKU: 186007318
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 100 mm, 1/pk - 186007318
List Price
$5425.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 100 mm, 1/pk - 186007318: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007318
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pk - 186007320
SKU: 186007320
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pk - 186007320
List Price
$12250.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pk - 186007320: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007320
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 100 mm, 1/pk - 186007332
SKU: 186007332
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 100 mm, 1/pk - 186007332
List Price
$2745.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 100 mm, 1/pk - 186007332: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007332
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 100 mm, 1/pk - 186007338
SKU: 186007338
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 100 mm, 1/pk - 186007338
List Price
$5425.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 100 mm, 1/pk - 186007338: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007338
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 50 mm, 1/pk - 186007311
SKU: 186007311
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 50 mm, 1/pk - 186007311
List Price
$1660.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 50 mm, 1/pk - 186007311: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007311
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pk - 186007319
SKU: 186007319
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pk - 186007319
List Price
$8125.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pk - 186007319: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007319
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pk - 186007340
SKU: 186007340
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pk - 186007340
List Price
$12250.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pk - 186007340: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007340
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 150000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 100 mm, 1/pk - 186007312
SKU: 186007312
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 100 mm, 1/pk - 186007312
List Price
$2745.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 100 mm, 1/pk - 186007312: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007312
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 150 mm, 1/pk - 186007333
SKU: 186007333
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 150 mm, 1/pk - 186007333
List Price
$3275.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 150 mm, 1/pk - 186007333: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007333
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pk - 186007339
SKU: 186007339
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pk - 186007339
List Price
$8125.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pk - 186007339: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007339
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH