Endcapped Shield RP18 OBD Prep Column

XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 50 mm, 1/pk - 186002220
SKU: 186002220
XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 50 mm, 1/pk - 186002220
List Price
$5910.00
Category: Columns
XTerra Shield RP18 OBD Prep Column, 125Å, 5 µm, 50 mm X 50 mm, 1/pk - 186002220: XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186002220
Brand: XTerra
Bonding Technology Shield RP18
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pk - 186002277
SKU: 186002277
XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pk - 186002277
List Price
$13315.00
Category: Columns
XTerra Shield RP18 OBD Prep Column, 125Å, 10 µm, 30 mm X 300 mm, 1/pk - 186002277: XTerra Preparative RP18 columns are hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186002277
Brand: XTerra
Bonding Technology Shield RP18
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186003995
SKU: 186003995
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186003995
List Price
$3915.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186003995: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003995
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pk - 186003996
SKU: 186003996
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pk - 186003996
List Price
$8125.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 150 mm, 1/pk - 186003996: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003996
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186003993
SKU: 186003993
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186003993
List Price
$2745.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186003993: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003993
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pk - 186002986
SKU: 186002986
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pk - 186002986
List Price
$2745.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pk - 186002986: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002986
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186003992
SKU: 186003992
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186003992
List Price
$1660.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186003992: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003992
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186003994
SKU: 186003994
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186003994
List Price
$3275.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186003994: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003994
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pk - 186003999
SKU: 186003999
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pk - 186003999
List Price
$9520.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 100 mm, 1/pk - 186003999: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003999
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004022
SKU: 186004022
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004022
List Price
$3915.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004022: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186004022
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002985
SKU: 186002985
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002985
List Price
$1660.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002985: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002985
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002988
SKU: 186002988
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002988
List Price
$3700.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002988: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002988
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pk - 186003262
SKU: 186003262
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pk - 186003262
List Price
$4485.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pk - 186003262: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003262
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pk - 186003935
SKU: 186003935
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pk - 186003935
List Price
$7535.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pk - 186003935: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003935
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pk - 186002987
SKU: 186002987
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pk - 186002987
List Price
$3275.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pk - 186002987: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002987
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pk - 186002990
SKU: 186002990
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pk - 186002990
List Price
$8125.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pk - 186002990: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002990
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186003939
SKU: 186003939
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186003939
List Price
$9520.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186003939: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003939
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186002989
SKU: 186002989
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186002989
List Price
$5425.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186002989: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186002989
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 10 mm X 50 mm, 1/pk - 186008168
SKU: 186008168
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 10 mm X 50 mm, 1/pk - 186008168
List Price
$1245.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 10 mm X 50 mm, 1/pk - 186008168: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008168
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 10 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 10 mm X 100 mm, 1/pk - 186008169
SKU: 186008169
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 10 mm X 100 mm, 1/pk - 186008169
List Price
$1455.00
Category: Columns
XBridge BEH Shield RP18 OBD Prep Column, 130Å, 5 µm, 10 mm X 100 mm, 1/pk - 186008169: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186008169
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 10 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 50 C (low pH)/45 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 11 pH