Carbohydrate Reversed-Phase Column

Carbohydrate Cartridge Column, 4.6 mm x 250 mm, 1/pk - WAT044355
SKU: WAT044355
Carbohydrate Cartridge Column, 4.6 mm x 250 mm, 1/pk - WAT044355
List Price
$1160.00
Category: Columns
Carbohydrate Cartridge Column, 4.6 mm x 250 mm, 1/pk - WAT044355: Waters High-Performance Carbohydrate Cartridge Column is packed with 4-μm spherical silica. This column was developed to separate five monosaccharides and disaccharides to give baseline resolution in fewer than 12 minutes. The pre-packed, disposable cartridge column requires reusable end-fittings, which are available separately.
Part Number: WAT044355
Application Carbohydrate
Format Cartridge
Inner Diameter 4.6 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 4 µm
Pore Size 60 Å
Product Type Cartridge Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L8
Units per Package 1 pk
Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk - WAT046895
SKU: WAT046895
Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk - WAT046895
List Price
$340.00
Category: Columns
Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk - WAT046895: The Carbohydrate Sentry Guard Cartridge is used to extend and prolong the lifetime for the Carbohydrate Cartridge Column by removing chemical and particulate contaminants from the mobile phase stream.
Part Number: WAT046895
Application Carbohydrate
Format Sentry Guard Cartridge
Inner Diameter 3.9 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 4 µm
Pore Size 60 Å
Product Type Guards
Separation Mode Reversed-Phase
System HPLC
USP Classification L20
Units per Package 2 pk
Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084038
SKU: WAT084038
Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084038
List Price
$1160.00
Category: Columns
Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084038: The Carbohydrate Analysis Column features a covalently bonded amino packing that is ideally suited for the seperation of low molecular weight sugars such as mono,di-, and trisaccharides. This column typically uses a mobile phase consisting of 65-85% acetonitrile in water and a column temperature ranging from ambient to 35° C.
Part Number: WAT084038
Application Carbohydrate
Chemistry Amino (NH2)
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L8
Units per Package 1 pk
pH Range 8 pH