C8 Reversed-Phase OBD Prep Column

SunFire C8 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pk - 186002870
SKU: 186002870
SunFire C8 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pk - 186002870
List Price
$9375.00
Category: Columns
SunFire C8 OBD Prep Column, 100Å, 5 µm, 50 mm X 100 mm, 1/pk - 186002870: SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.
Part Number: 186002870
Brand: SunFire
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L7
Units per Package 1 pk
pH Range 8 pH
SunFire C8 OBD Prep Column, 100Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002764
SKU: 186002764
SunFire C8 OBD Prep Column, 100Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002764
List Price
$3575.00
Category: Columns
SunFire C8 OBD Prep Column, 100Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002764: SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.
Part Number: 186002764
Brand: SunFire
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L7
Units per Package 1 pk
pH Range 8 pH
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 50 mm, 1/pk - 186001931
SKU: 186001931
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 50 mm, 1/pk - 186001931
List Price
$1570.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 50 mm, 1/pk - 186001931: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001931
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pk - 186002844
SKU: 186002844
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pk - 186002844
List Price
$11225.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 150 mm, 1/pk - 186002844: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002844
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pk - 186001943
SKU: 186001943
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pk - 186001943
List Price
$5140.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 100 mm, 1/pk - 186001943: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001943
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pk - 186002223
SKU: 186002223
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pk - 186002223
List Price
$9015.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 50 mm X 100 mm, 1/pk - 186002223: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002223
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 50 mm, 1/pk - 186002280
SKU: 186002280
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 50 mm, 1/pk - 186002280
List Price
$5910.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 50 mm X 50 mm, 1/pk - 186002280: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002280
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 250 mm, 1/pk - 186002272
SKU: 186002272
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 250 mm, 1/pk - 186002272
List Price
$11675.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 250 mm, 1/pk - 186002272: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002272
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pk - 186002264
SKU: 186002264
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pk - 186002264
List Price
$4180.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pk - 186002264: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002264
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 75 mm, 1/pk - 186002388
SKU: 186002388
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 75 mm, 1/pk - 186002388
List Price
$4245.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 30 mm X 75 mm, 1/pk - 186002388: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002388
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 150 mm, 1/pk - 186002380
SKU: 186002380
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 150 mm, 1/pk - 186002380
List Price
$3105.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 150 mm, 1/pk - 186002380: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002380
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002260
SKU: 186002260
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002260
List Price
$3710.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002260: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002260
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pk - 186002268
SKU: 186002268
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pk - 186002268
List Price
$7715.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 30 mm X 150 mm, 1/pk - 186002268: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002268
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 150 mm, 1/pk - 186002256
SKU: 186002256
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 150 mm, 1/pk - 186002256
List Price
$3105.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 10 µm, 19 mm X 150 mm, 1/pk - 186002256: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186002256
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 100 mm, 1/pk - 186001935
SKU: 186001935
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 100 mm, 1/pk - 186001935
List Price
$2610.00
Category: Columns
XTerra MS C8 OBD Prep Column, 125Å, 5 µm, 19 mm X 100 mm, 1/pk - 186001935: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001935
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186004008
SKU: 186004008
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186004008
List Price
$2745.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 100 mm, 1/pk - 186004008: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004008
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186004010
SKU: 186004010
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186004010
List Price
$3915.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 250 mm, 1/pk - 186004010: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004010
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186004007
SKU: 186004007
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186004007
List Price
$1660.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 50 mm, 1/pk - 186004007: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004007
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186004009
SKU: 186004009
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186004009
List Price
$3275.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 19 mm X 150 mm, 1/pk - 186004009: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004009
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pk - 186004013
SKU: 186004013
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pk - 186004013
List Price
$7535.00
Category: Columns
XBridge BEH C8 OBD Prep Column, 130Å, 10 µm, 50 mm X 50 mm, 1/pk - 186004013: The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186004013
Brand: XBridge
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60 C (Low pH) / 60 C (High pH)
USP Classification L7
Units per Package 1 pk
pH Range 12 pH