C4 Reversed-Phase Column

XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 250 mm, 1/pk - 186007314
SKU: 186007314
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 250 mm, 1/pk - 186007314
List Price
$3915.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 250 mm, 1/pk - 186007314: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007314
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pk - 186007313
SKU: 186007313
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pk - 186007313
List Price
$3275.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pk - 186007313: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007313
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 100 mm, 1/pk - 186007318
SKU: 186007318
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 100 mm, 1/pk - 186007318
List Price
$5425.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 100 mm, 1/pk - 186007318: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007318
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pk - 186007320
SKU: 186007320
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pk - 186007320
List Price
$12250.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 250 mm, 1/pk - 186007320: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007320
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 100 mm, 1/pk - 186007332
SKU: 186007332
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 100 mm, 1/pk - 186007332
List Price
$2745.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 100 mm, 1/pk - 186007332: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007332
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 100 mm, 1/pk - 186007338
SKU: 186007338
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 100 mm, 1/pk - 186007338
List Price
$5425.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 100 mm, 1/pk - 186007338: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007338
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 50 mm, 1/pk - 186007311
SKU: 186007311
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 50 mm, 1/pk - 186007311
List Price
$1660.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 50 mm, 1/pk - 186007311: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007311
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pk - 186007319
SKU: 186007319
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pk - 186007319
List Price
$8125.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 150 mm, 1/pk - 186007319: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007319
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pk - 186007340
SKU: 186007340
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pk - 186007340
List Price
$12250.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 250 mm, 1/pk - 186007340: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007340
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 150000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 100 mm, 1/pk - 186007312
SKU: 186007312
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 100 mm, 1/pk - 186007312
List Price
$2745.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 100 mm, 1/pk - 186007312: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007312
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 150 mm, 1/pk - 186007333
SKU: 186007333
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 150 mm, 1/pk - 186007333
List Price
$3275.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 150 mm, 1/pk - 186007333: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007333
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pk - 186007339
SKU: 186007339
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pk - 186007339
List Price
$8125.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 150 mm, 1/pk - 186007339: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007339
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 75 mm, 1/pk - 186007337
SKU: 186007337
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 75 mm, 1/pk - 186007337
List Price
$4485.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 75 mm, 1/pk - 186007337: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007337
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 250 mm, 1/pk - 186007334
SKU: 186007334
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 250 mm, 1/pk - 186007334
List Price
$3915.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 19 mm X 250 mm, 1/pk - 186007334: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007334
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 50 mm, 1/pk - 186007336
SKU: 186007336
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 50 mm, 1/pk - 186007336
List Price
$3700.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 10 µm, 30 mm X 50 mm, 1/pk - 186007336: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007336
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 10K - 500K, 3/pk - 186004623
SKU: 186004623
ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 10K - 500K, 3/pk - 186004623
List Price
$735.00
Category: Columns
ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 10K - 500K, 3/pk - 186004623: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186004623
Brand: ACQUITY UPLC
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 500000
Molecular Weight Range Min 10000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Guards
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
System UHPLC, UPLC
USP Classification L26
Units per Package 3 pk
pH Range 12 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 50 mm, 1/pk - 186007316
SKU: 186007316
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 50 mm, 1/pk - 186007316
List Price
$3700.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 50 mm, 1/pk - 186007316: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007316
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 75 mm, 1/pk - 186007317
SKU: 186007317
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 75 mm, 1/pk - 186007317
List Price
$4485.00
Category: Columns
XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 30 mm X 75 mm, 1/pk - 186007317: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.
Part Number: 186007317
Brand: XBridge
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Preparative Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 10 pH
DeltaPak C4 Radial-Pak Column, 300Å, 15 µm, 47 mm X 300 mm, 1/pk - WAT011669
SKU: WAT011669
DeltaPak C4 Radial-Pak Column, 300Å, 15 µm, 47 mm X 300 mm, 1/pk - WAT011669
List Price
$3350.00
Category: Columns
DeltaPak C4 Radial-Pak Column, 300Å, 15 µm, 47 mm X 300 mm, 1/pk - WAT011669: Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.
Part Number: WAT011669
Brand: Delta-Pak
Application Protein
Carbon Load 3 %
Chemistry C4
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 47 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 15 µm
Particle Substrate Silica
Pore Size 300 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 125
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 8 pH
DeltaPak C4 Radial-Pak Column, 100Å, 15 µm, 25 mm X 100 mm, 1/pk - WAT038508
SKU: WAT038508
DeltaPak C4 Radial-Pak Column, 100Å, 15 µm, 25 mm X 100 mm, 1/pk - WAT038508
List Price
$700.00
Category: Columns
DeltaPak C4 Radial-Pak Column, 100Å, 15 µm, 25 mm X 100 mm, 1/pk - WAT038508: Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.
Part Number: WAT038508
Brand: Delta-Pak
Application Protein
Carbon Load 7 %
Chemistry C4
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 25 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 15 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 300
System HPLC
USP Classification L26
Units per Package 1 pk
pH Range 8 pH