C18 Reversed-Phase Column

Resolve C18 Radial-Pak Column, 90Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT084720
SKU: WAT084720
Resolve C18 Radial-Pak Column, 90Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT084720
List Price
$485.00
Category: Columns
Resolve C18 Radial-Pak Column, 90Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT084720: The non-encapped Resolve C18 column offers significantly different selectivity compared to similar HPLC packings like Nova-Pak and µBondapak. The change in chromatographic behavior is most commonly noticed with polar compounds, which are typically more retained.
Part Number: WAT084720
Brand: Resolve
Carbon Load 10 %
Chemistry C18
Endcapped No
Format Radial-Pak Column
Inner Diameter 8 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Silica
Pore Size 90 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 200
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Resolve C18 Radial-Pak Column, 90Å, 10 µm, 5 mm X 100 mm, 1/pk - WAT084620
SKU: WAT084620
Resolve C18 Radial-Pak Column, 90Å, 10 µm, 5 mm X 100 mm, 1/pk - WAT084620
List Price
$485.00
Category: Columns
Resolve C18 Radial-Pak Column, 90Å, 10 µm, 5 mm X 100 mm, 1/pk - WAT084620: The non-encapped Resolve C18 column offers significantly different selectivity compared to similar HPLC packings like Nova-Pak and µBondapak. The change in chromatographic behavior is most commonly noticed with polar compounds, which are typically more retained.
Part Number: WAT084620
Brand: Resolve
Carbon Load 10 %
Chemistry C18
Endcapped No
Format Radial-Pak Column
Inner Diameter 5 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Silica
Pore Size 90 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 200
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Bondapak C18 Radial-Pak Column, 125Å, 37 - 55 µm, 8 mm X 100 mm, 1/pk - WAT036561
SKU: WAT036561
Bondapak C18 Radial-Pak Column, 125Å, 37 - 55 µm, 8 mm X 100 mm, 1/pk - WAT036561
List Price
$425.00
Category: Columns
Bondapak C18 Radial-Pak Column, 125Å, 37 - 55 µm, 8 mm X 100 mm, 1/pk - WAT036561: Bondapak C18 is available in two different particle sizes, 15-20µm and 37-55µm, providing easy method transfer from µBondapak through preparative scale up. If you are developing a new purification protocol, Bondapak provides the best balance between resolution, throughput and cost.
Part Number: WAT036561
Brand: Bondapak
Carbon Load 14 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 8 mm
Length 100 mm
Maximum Pressure 1500 psi (100 Bar)
Particle Shape Irregular
Particle Size 37 - 55 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Bondapak C18 Radial-Pak Column, 300Å, 15 - 20 µm, 47 mm X 300 mm, 1/pk - WAT038571
SKU: WAT038571
Bondapak C18 Radial-Pak Column, 300Å, 15 - 20 µm, 47 mm X 300 mm, 1/pk - WAT038571
List Price
$2645.00
Category: Columns
Bondapak C18 Radial-Pak Column, 300Å, 15 - 20 µm, 47 mm X 300 mm, 1/pk - WAT038571: Bondapak C18 is available in two different particle sizes, 15-20µm and 37-55µm, providing easy method transfer from µBondapak through preparative scale up. If you are developing a new purification protocol, Bondapak provides the best balance between resolution, throughput and cost.
Part Number: WAT038571
Brand: Bondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 47 mm
Length 300 mm
Maximum Pressure 600 psi (40 Bar)
Particle Shape Irregular
Particle Size 15 - 20 µm
Particle Substrate Silica
Pore Size 300 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Bondapak C18 Radial-Pak Column, 125Å, 15 - 20 µm, 47 mm X 300 mm, 1/pk - WAT091784
SKU: WAT091784
Bondapak C18 Radial-Pak Column, 125Å, 15 - 20 µm, 47 mm X 300 mm, 1/pk - WAT091784
List Price
$2830.00
Category: Columns
Bondapak C18 Radial-Pak Column, 125Å, 15 - 20 µm, 47 mm X 300 mm, 1/pk - WAT091784: Bondapak C18 is available in two different particle sizes, 15-20µm and 37-55µm, providing easy method transfer from µBondapak through preparative scale up. If you are developing a new purification protocol, Bondapak provides the best balance between resolution, throughput and cost.
Part Number: WAT091784
Brand: Bondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 47 mm
Length 300 mm
Maximum Pressure 600 psi (40 Bar)
Particle Shape Irregular
Particle Size 15 - 20 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Bondapak C18 Radial-Pak Column, 125Å, 15 - 20 µm, 25 mm X 100 mm, 1/pk - WAT038503
SKU: WAT038503
Bondapak C18 Radial-Pak Column, 125Å, 15 - 20 µm, 25 mm X 100 mm, 1/pk - WAT038503
List Price
$845.00
Category: Columns
Bondapak C18 Radial-Pak Column, 125Å, 15 - 20 µm, 25 mm X 100 mm, 1/pk - WAT038503: Bondapak C18 is available in two different particle sizes, 15-20µm and 37-55µm, providing easy method transfer from µBondapak through preparative scale up. If you are developing a new purification protocol, Bondapak provides the best balance between resolution, throughput and cost.
Part Number: WAT038503
Brand: Bondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 25 mm
Length 100 mm
Maximum Pressure 1500 psi (100 Bar)
Particle Shape Irregular
Particle Size 15 - 20 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Resolve C18 Radial-Pak Column, 90Å, 5 µm, 8 mm X 100 mm, 1/pk - WAT084624
SKU: WAT084624
Resolve C18 Radial-Pak Column, 90Å, 5 µm, 8 mm X 100 mm, 1/pk - WAT084624
List Price
$605.00
Category: Columns
Resolve C18 Radial-Pak Column, 90Å, 5 µm, 8 mm X 100 mm, 1/pk - WAT084624: The non-encapped Resolve C18 column offers significantly different selectivity compared to similar HPLC packings like Nova-Pak and µBondapak. The change in chromatographic behavior is most commonly noticed with polar compounds, which are typically more retained.
Part Number: WAT084624
Brand: Resolve
Carbon Load 10 %
Chemistry C18
Endcapped No
Format Radial-Pak Column
Inner Diameter 8 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 90 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 200
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
ACQUITY UPLC HSS C18 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk - 186003981
SKU: 186003981
ACQUITY UPLC HSS C18 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk - 186003981
List Price
$735.00
Category: Columns
ACQUITY UPLC HSS C18 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk - 186003981: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186003981
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 8 pH
ACQUITY UPLC CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186005303
SKU: 186005303
ACQUITY UPLC CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186005303
List Price
$735.00
Category: Columns
ACQUITY UPLC CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186005303: ACQUITY CSH C18 columns were designed to provide alternate selectivity compared to other reversed-phase UPLC columns. These ultra-efficient columns overcome peak shape asymmetry and poor loading capacity for basic compounds, column bleed, and rapid mobile-phase re-equilibration. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186005303
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT085721
SKU: WAT085721
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT085721
List Price
$470.00
Category: Columns
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT085721: µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.
Part Number: WAT085721
Brand: µBondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 8 mm
Length 100 mm
Maximum Pressure 1500 psi (100 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 25 mm X 100 mm, 1/pk - WAT038505
SKU: WAT038505
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 25 mm X 100 mm, 1/pk - WAT038505
List Price
$970.00
Category: Columns
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 25 mm X 100 mm, 1/pk - WAT038505: µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.
Part Number: WAT038505
Brand: µBondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 25 mm
Length 100 mm
Maximum Pressure 1500 psi (100 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 40 mm X 100 mm, 1/pk - WAT037684
SKU: WAT037684
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 40 mm X 100 mm, 1/pk - WAT037684
List Price
$2015.00
Category: Columns
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 40 mm X 100 mm, 1/pk - WAT037684: µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.
Part Number: WAT037684
Brand: µBondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 40 mm
Length 100 mm
Maximum Pressure 1500 psi (100 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003975
SKU: 186003975
ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003975
List Price
$735.00
Category: Columns
ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003975: As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186003975
Brand: ACQUITY UPLC
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 1K - 30K, 3/pk - 186004629
SKU: 186004629
ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 1K - 30K, 3/pk - 186004629
List Price
$735.00
Category: Columns
ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 1K - 30K, 3/pk - 186004629: VanGuard pre-columns are the first guard column devices designed for routine use at pressures up to 15000 psi (1030 bar) in applications run on the ACQUITY UPLC System. This specific offering contains Waters patented BEH Technology C18, 300A pore, 1.7um particles based and each batch is specifically QC tested with a peptide map to help ensure consistent performance and increased analytical column life.
Part Number: 186004629
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Guards
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186006939
SKU: 186006939
ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186006939
List Price
$735.00
Category: Columns
ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186006939: Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186006939
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Guards
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002977
SKU: 186002977
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002977
List Price
$1660.00
Category: Columns
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002977: As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Part Number: 186002977
Brand: XBridge
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 80 C (Low pH)/60 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002566
SKU: 186002566
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002566
List Price
$1515.00
Category: Columns
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 50 mm, 1/pk - 186002566: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002566
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
SunFire C18 OBD Prep Column, 100Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002669
SKU: 186002669
SunFire C18 OBD Prep Column, 100Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002669
List Price
$3575.00
Category: Columns
SunFire C18 OBD Prep Column, 100Å, 10 µm, 19 mm X 250 mm, 1/pk - 186002669: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002669
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002570
SKU: 186002570
SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002570
List Price
$3370.00
Category: Columns
SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pk - 186002570: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002570
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004027
SKU: 186004027
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004027
List Price
$3575.00
Category: Columns
SunFire C18 OBD Prep Column, 100Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004027: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186004027
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH