Acquity Uplc Beh c8 Column

ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pk - 186003374
SKU: 186003374
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pk - 186003374
List Price
$985.00
Category: Columns
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pk - 186003374: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 186003374
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 1 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk - 176000883
SKU: 176000883
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk - 176000883
List Price
$2535.00
Category: Columns
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk - 176000883: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 176000883
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 30 mm, 3/pk - 176001798
SKU: 176001798
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 30 mm, 3/pk - 176001798
List Price
$2430.00
Category: Columns
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 30 mm, 3/pk - 176001798: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 176001798
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 176001799
SKU: 176001799
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 176001799
List Price
$2485.00
Category: Columns
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 176001799: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 176001799
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 176001800
SKU: 176001800
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 176001800
List Price
$2535.00
Category: Columns
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 176001800: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 176001800
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk - 176001310
SKU: 176001310
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk - 176001310
List Price
$2430.00
Category: Columns
ACQUITY UPLC BEH C8 Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk - 176001310: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.
Part Number: 176001310
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 186004046
SKU: 186004046
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 186004046
List Price
$2760.00
Category: Columns
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 186004046: This kit consists of three ACQUITY UPLC BEH C8 columns packed with three different batches of sorbent.
Part Number: 186004046
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pk - 186004047
SKU: 186004047
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pk - 186004047
List Price
$2820.00
Category: Columns
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pk - 186004047: This kit consists of three ACQUITY UPLC BEH C8 columns packed with three different batches of sorbent.
Part Number: 186004047
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 186004693
SKU: 186004693
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 186004693
List Price
$2760.00
Category: Columns
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 186004693: This kit consists of three ACQUITY UPLC BEH C8 columns packed with three different batches of sorbent.
Part Number: 186004693
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 3 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006020
SKU: 186006020
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006020
List Price
$2955.00
Category: Columns
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006020: This kit consists of three ACQUITY UPLC BEH C8 columns packed with three different batches of sorbent.
Part Number: 186006020
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 186004694
SKU: 186004694
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 186004694
List Price
$2820.00
Category: Columns
ACQUITY UPLC BEH C8 Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 186004694: This kit consists of three ACQUITY UPLC BEH C8 columns packed with three different batches of sorbent.
Part Number: 186004694
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 3 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
eCord Yes
pH Range 12 pH
ACQUITY UPLC BEH C8 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003978
SKU: 186003978
ACQUITY UPLC BEH C8 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003978
List Price
$735.00
Category: Columns
ACQUITY UPLC BEH C8 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003978: The ACQUITY BEH C8 sorbent is less retentive compared to the ACQUITY BEH C18 sorbent. A method developer may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded BEH particles offer the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186003978
Brand: ACQUITY UPLC
Carbon Load 13 %
Chemistry C8
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L7
Units per Package 3 pk
pH Range 12 pH