ACQUITY UPLC BEH Amide Column

ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 1/pk - 186004839
SKU: 186004839
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 1/pk - 186004839
List Price
$900.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 1/pk - 186004839: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 186004839
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004801
SKU: 186004801
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004801
List Price
$940.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004801: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 186004801
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 150 mm, 1/pk - 186004806
SKU: 186004806
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 150 mm, 1/pk - 186004806
List Price
$985.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 150 mm, 1/pk - 186004806: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 186004806
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 30 mm, 1/pk - 186004803
SKU: 186004803
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 30 mm, 1/pk - 186004803
List Price
$900.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 30 mm, 1/pk - 186004803: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 186004803
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 176001912
SKU: 176001912
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 176001912
List Price
$2535.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 176001912: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 176001912
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 150 mm, 3/pk - 176001913
SKU: 176001913
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 150 mm, 3/pk - 176001913
List Price
$2660.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 3 mm X 150 mm, 3/pk - 176001913: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 176001913
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 3 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186004799
SKU: 186004799
ACQUITY UPLC BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186004799
List Price
$735.00
Category: Columns
ACQUITY UPLC BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186004799: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186004799
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Guards
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
pH Range 11 pH
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 186004809
SKU: 186004809
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 186004809
List Price
$2760.00
Category: Columns
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 3 mm X 50 mm, 3/pk - 186004809: This kit consists of three ACQUITY UPLC BEH Amide columns packed with three different batches of sorbent.
Part Number: 186004809
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 3 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pk - 186004808
SKU: 186004808
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pk - 186004808
List Price
$2820.00
Category: Columns
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 100 mm, 3/pk - 186004808: This kit consists of three ACQUITY UPLC BEH Amide columns packed with three different batches of sorbent.
Part Number: 186004808
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 186004807
SKU: 186004807
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 186004807
List Price
$2760.00
Category: Columns
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 186004807: This kit consists of three ACQUITY UPLC BEH Amide columns packed with three different batches of sorbent.
Part Number: 186004807
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006024
SKU: 186006024
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006024
List Price
$2519.00
Category: Columns
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006024: This kit consists of three ACQUITY UPLC BEH Amide columns packed with three different batches of sorbent.
Part Number: 186006024
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 186004810
SKU: 186004810
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 186004810
List Price
$2820.00
Category: Columns
ACQUITY UPLC BEH Amide Method Validation Kit, 130Å, 1.7 µm, 3 mm X 100 mm, 3/pk - 186004810: This kit consists of three ACQUITY UPLC BEH Amide columns packed with three different batches of sorbent.
Part Number: 186004810
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 3 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004741
SKU: 186004741
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004741
List Price
$985.00
Category: Columns
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004741: The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.
Part Number: 186004741
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Molecular Weight Range Max 150000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Glycan
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
pH Range 11 pH
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186004742
SKU: 186004742
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186004742
List Price
$1035.00
Category: Columns
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186004742: The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.
Part Number: 186004742
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 150000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Glycan
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
pH Range 11 pH
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186004740
SKU: 186004740
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186004740
List Price
$965.00
Category: Columns
ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186004740: The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.
Part Number: 186004740
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Molecular Weight Range Max 150000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Glycan
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
pH Range 11 pH
ACQUITY - XBridge BEH Amide Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 100 - 150mm, 2/pk - 186004974
SKU: 186004974
ACQUITY - XBridge BEH Amide Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 100 - 150mm, 2/pk - 186004974
List Price
$1860.00
Category: Columns
ACQUITY - XBridge BEH Amide Method Transfer Kit, 130Å, 1.7 - 3.5 µm, 2.1 - 4.6 mm X 100 - 150mm, 2/pk - 186004974: Method transfer kits are designed to preserve the integrity of a separation as it is transferred between UPLC and HPLC platforms. Based on the concept of maintaining column length [L] to particle size [dp] ratio [L/dp], these kits provide an ACQUITY UPLC column with an HPLC column of equivalent selectivity and resolving power. Using the ACQUITY UPLC columns calculator, methods can be fully transferred from HPLC to UPLC or from UPLC to HPLC.
Part Number: 186004974
Brand: ACQUITY UPLC, XBridge
Carbon Load 12 %
Chemistry Amide
Endcapped No
Format Method Transfer Kit
Particle Shape Spherical
Particle Size 1.7 - 3.5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
Separation Mode Hydrophilic Interaction (HILIC)
Surface Area 185
USP Classification L68
Units per Package 2 pk
pH Range 11 pH
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk with Glycoprotein Performance Test Standard - 176003700
SKU: 176003700
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk with Glycoprotein Performance Test Standard - 176003700
List Price
$965.00
Category: Columns
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk with Glycoprotein Performance Test Standard - 176003700: Waters Glycoprotein BEH Amide 300A, 1.7um columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides.. Each batch of Glycoprotein BEH Amide 300A 1.7um material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 86008010 that includes a mixture of Ribonuclease A as well as Ribonulease B glycoforms) to help ensure batch to batch consistency. This kit includes one Glycoprotein BEH Amide 300A, 1.7um column and one vial of Waters Glycoprotein Performance Test Standard. The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003700
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Molecular Weight Range Max 500000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Glycoprotein
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
pH Range 10 pH
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk with Glycoprotein Performance Test Standard - 176003701
SKU: 176003701
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk with Glycoprotein Performance Test Standard - 176003701
List Price
$985.00
Category: Columns
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk with Glycoprotein Performance Test Standard - 176003701: Waters Glycoprotein BEH Amide 300Å, 1.7 μm columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides.. Each batch of Glycoprotein BEH Amide 300Å 1.7 μm material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 186008010 that includes a mixture of ribonuclease A as well as ribonulease B glycoforms) to help ensure batch to batch consistency. This kit includes one Glycoprotein BEH Amide 300Å, 1.7 μm column and one vial of Waters Glycoprotein Performance Test Standard. The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003701
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 500000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Guards
QC Tested Glycoprotein
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
pH Range 10 pH
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk with Glycoprotein Performance Test Standard - 176003702
SKU: 176003702
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk with Glycoprotein Performance Test Standard - 176003702
List Price
$1035.00
Category: Columns
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk with Glycoprotein Performance Test Standard - 176003702: Waters Glycoprotein BEH Amide 300A, 1.7um columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides.. Each batch of Glycoprotein BEH Amide 300A 1.7um material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 86008010 that includes a mixture of Ribonuclease A as well as Ribonulease B glycoforms) to help ensure batch to batch consistency. This kit includes one Glycoprotein BEH Amide 300A, 1.7um column and one vial of Waters Glycoprotein Performance Test Standard. The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003702
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 500000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Glycoprotein
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
pH Range 10 pH
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186007961
SKU: 186007961
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186007961
List Price
$943.00
Category: Columns
ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186007961: Waters Glycoprotein BEH Amide 300A, 1.7μm columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides. Each batch of Glycoprotein BEH Amide 300A 1.7μm material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 86008010 that includes a mixture of Ribonuclease A as well as Ribonulease B glycoforms) to help ensure batch to batch consistency.
Part Number: 186007961
Brand: ACQUITY UPLC
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Glycoprotein
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UPLC
USP Classification L68
Units per Package 1 pk
pH Range 10 pH