C18 Column

SunFire C18 Column, 100Å, 2.5 µm, 3 mm X 30 mm, 1/pk - 186003407
SKU: 186003407
SunFire C18 Column, 100Å, 2.5 µm, 3 mm X 30 mm, 1/pk - 186003407
List Price
$650.00
Category: Columns
SunFire C18 Column, 100Å, 2.5 µm, 3 mm X 30 mm, 1/pk - 186003407: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186003407
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3 mm
Length 30 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 186002553
SKU: 186002553
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 186002553
List Price
$735.00
Category: Columns
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 186002553: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002553
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 3/pk - 176001121
SKU: 176001121
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 3/pk - 176001121
List Price
$2485.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 3/pk - 176001121: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 176001121
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 150 mm, 3/pk - 176001123
SKU: 176001123
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 150 mm, 3/pk - 176001123
List Price
$2660.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 150 mm, 3/pk - 176001123: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 176001123
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pk - 186003532
SKU: 186003532
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pk - 186003532
List Price
$920.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pk - 186003532: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 186003532
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 1/pk - 186003987
SKU: 186003987
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 1/pk - 186003987
List Price
$900.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 1/pk - 186003987: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 186003987
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pk - 186003534
SKU: 186003534
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pk - 186003534
List Price
$985.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pk - 186003534: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 186003534
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 100 mm, 3/pk - 176001122
SKU: 176001122
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 100 mm, 3/pk - 176001122
List Price
$2535.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 100 mm, 3/pk - 176001122: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 176001122
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 3/pk - 176001398
SKU: 176001398
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 3/pk - 176001398
List Price
$2430.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 3/pk - 176001398: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 176001398
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pk - 186003529
SKU: 186003529
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pk - 186003529
List Price
$920.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pk - 186003529: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 186003529
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 3/pk - 176001126
SKU: 176001126
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 3/pk - 176001126
List Price
$2660.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 3/pk - 176001126: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 176001126
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
eCord Yes
pH Range 8 pH
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 100 mm, 1/pk - 186003530
SKU: 186003530
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 100 mm, 1/pk - 186003530
List Price
$940.00
Category: Columns
ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 1 mm X 100 mm, 1/pk - 186003530: ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.
Part Number: 186003530
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
eCord Yes
pH Range 8 pH
BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 250 mm, 1K - 15K, 1/pk - 186002428
SKU: 186002428
BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 250 mm, 1K - 15K, 1/pk - 186002428
List Price
$875.00
Category: Columns
BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 250 mm, 1K - 15K, 1/pk - 186002428: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002428
Brand: BioSuite
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 50 mm, 1K - 15K, 1/pk - 186002429
SKU: 186002429
BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 50 mm, 1K - 15K, 1/pk - 186002429
List Price
$615.00
Category: Columns
BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 50 mm, 1K - 15K, 1/pk - 186002429: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002429
Brand: BioSuite
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 1K - 30K, 1/pk - 186002435
SKU: 186002435
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 1K - 30K, 1/pk - 186002435
List Price
$785.00
Category: Columns
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 1K - 30K, 1/pk - 186002435: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002435
Brand: BioSuite
Application Peptide
Carbon Load 8.5 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 300 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1K - 30K, 1/pk - 186002433
SKU: 186002433
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1K - 30K, 1/pk - 186002433
List Price
$615.00
Category: Columns
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1K - 30K, 1/pk - 186002433: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002433
Brand: BioSuite
Application Peptide
Carbon Load 8.5 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 300 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1K - 15K, 1/pk - 186002430
SKU: 186002430
BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1K - 15K, 1/pk - 186002430
List Price
$730.00
Category: Columns
BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1K - 15K, 1/pk - 186002430: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002430
Brand: BioSuite
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
BioSuite C18 Column, 500Å, 7 µm, 2 mm X 150 mm, 1K - 30K, 1/pk - 186002153
SKU: 186002153
BioSuite C18 Column, 500Å, 7 µm, 2 mm X 150 mm, 1K - 30K, 1/pk - 186002153
List Price
$905.00
Category: Columns
BioSuite C18 Column, 500Å, 7 µm, 2 mm X 150 mm, 1K - 30K, 1/pk - 186002153: In recent years, reversed-phase chromatography (RPC) has become a widely accepted tool for the separation of proteins, peptides, and other biomolecules. For many applications, Waters Symmetry®, Symmetry300™, and Atlantis™, and XTerra® chemistries can be successfully used for the isolation and analyses of these biocompounds. However for some applications, the large pore size and high chemical stability of Waters BioSuite™ pC18 and pPhenyl resin-based packings may be preferred. Waters BioSuite™ RPC column offerings include a C18 (pC18) and a phenyl (pPhenyl) chemistry bonded to a pH stable, methacrylic ester-based polymeric resin. The 500 angstrom pore size of the pC18 base matrix accommodates proteins up to 2,500,000 Daltons while the 1,000 angstrom pore size of the pPhenyl base matrix accommodates proteins up to 5,000,000 Daltons. The BioSuite™ pC18, 2.5 µm, NP column contains a nonporous chemistry that yields superior chromatographic resolution compared to chromatography performed on the porous, pC18, 500, 7 µm RPC selection. However, greater protein or peptide binding capacity is possible using the porous, pC18, 500, 7 µm RPC column. The pC18 and pPhenyl RPC chemistries are available in 21.5 x 150 mm columns for “lab scale” isolations while a 2.0 mm x 75 mm column is well suited for narrow-bore HPLC and /or LC/MS applications.
Part Number: 186002153
Brand: BioSuite
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 7 µm
Particle Substrate Polymethacrylate
Pore Size 500 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 100 mm, 1K - 30K, 1/pk - 186002434
SKU: 186002434
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 100 mm, 1K - 30K, 1/pk - 186002434
List Price
$730.00
Category: Columns
BioSuite C18 Column, 300Å, 3.5 µm, 2.1 mm X 100 mm, 1K - 30K, 1/pk - 186002434: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002434
Brand: BioSuite
Application Peptide
Carbon Load 8.5 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 300 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk - 186002426
SKU: 186002426
BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk - 186002426
List Price
$730.00
Category: Columns
BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk - 186002426: BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.
Part Number: 186002426
Brand: BioSuite
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH