Product Listing:  Oasis PRiME HLB 96-well µElution Plate, 3 mg Sorbent per Well, 1/pk - 186008052 to Synthetic Vacuum Pump Oil - 700011138

Oasis PRiME HLB 96-well µElution Plate, 3 mg Sorbent per Well, 1/pk - 186008052
SKU: 186008052
Oasis PRiME HLB 96-well µElution Plate, 3 mg Sorbent per Well, 1/pk - 186008052
List Price
$345.00
Category: Sample Preparation & Filtration
Oasis PRiME HLB 96-well µElution Plate, 3 mg Sorbent per Well, 1/pk - 186008052: Oasis PRiME HLB sets the new performance standard for solid phase extraction cleanup in routine analysis. This sorbent will provide reversed-phase cleanup of acidic, basic and neutral compounds form complex sample matrices. Oasis PRiME HLB has been designed to simplify SPE with fast, easy protocols. It also produces cleaner samples by removing greater than 95% of common matrix interferences such as salts, proteins and phospholipids. Additionally, viscous samples can be processed with faster flows through the device and less plugging. Based on the Oasis HLB sorbent technology, this water-wettable sorbent does not require conditioning and equilibration to provide excellent recoveries.
Part Number: 186008052
Brand: Oasis
Chemistry PRiME HLB
Endcapped No
Format 96-well µElution Plate
Mass Spec Compatibility Yes
Material Polypropylene
Mode Reversed-phase
Number of Wells 96
Product Type Solid Phase Extraction
Sorbent Weight 3 mg
Units per Package 1 pk
Water Wettable Yes
XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005380
SKU: 186005380
XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005380
List Price
$930.00
Category: Columns
XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005380: XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.
Part Number: 186005380
Brand: XSelect
Bonding Technology Phenyl-Hexyl
Carbon Load 14 %
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L11
Units per Package 1 pk
pH Range 11 pH
XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pk - 186003117
SKU: 186003117
XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pk - 186003117
List Price
$985.00
Category: Columns
XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pk - 186003117: As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Part Number: 186003117
Brand: XBridge
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186003462
SKU: 186003462
ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186003462
List Price
$985.00
Category: Columns
ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186003462: ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.
Part Number: 186003462
Brand: ACQUITY UPLC
Chemistry HILIC
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L3
Units per Package 1 pk
eCord Yes
pH Range 9 pH
Xevo TQ Standards Kit - 700004045
SKU: 700004045
Xevo TQ Standards Kit - 700004045
List Price
$1260.00
Category: Standards & Reagents
Xevo TQ Standards Kit - 700004045: Mass Spectrometry (XEVO TQ) standards kit for system assessment. 10 Components 1. 1X 25mL Tuning Solution X 10: Acetominophen (4-Acetamidophenol) 200pg/ul, Caffeine 200pg/ul, Sulfadimethoxine 100pg/ul, Verapamil, 50pg/ul, Chloramphenicol, 50pg/ul, 1 x 17-A-Hydroxyprogesterone, 5000pg/ul in 90% MeOH:10% Water Flame Sealed Ampule 2. 1 x 30mL Set up Solution QP: PPG1000 2.5 ng/ul, Triacetyl-B-cyclodextrin 5.0 ng/ul, Verapmil 100.0 pg/ul, Leucine Enkaphalin 1.0 ng/ul, Ammonium Acetate 0.31 mg/ml Acetonitrile/Water (1:1 V/V) Clear Nalgene Bottle 3. 1 x 30mL Calibration Solution: Sodium Iodide 2 ug/ul (+1%, -0%) Cesium Iodide 50 ng/ul (+1%, -0%) IPA/Water (1:1 V/V), Clear Nalgene Bottle 4. 1X 10mg Ion Sabre APCI Pos Sensitivity: 17-alphahydroxyprogesterone 10 mg solid in 4 ml Amber Screw Top Vial 5. 1X 50 mg ESI Negative Sensitivity: Chloramphenicol Solid 50mg 8 ml Amber Screw Top Vial 6. 1 X 5mg ESI Positive Sensitivity: Reserpine solid 5 mg in 4 ml Amber Screw Top Vial 7. 1 x 5mg Ion Sabre APCI Neg Sensitivity: Sulfadimethoxine Solid 5mg in 4 ml Amber Screw Top Vial 8. 1 x 0.1mg*Scanwave optimisation: [Glu1]-Fibrinopeptide B 0.1 mg ±0.01 mg in 4 mL Amber Screw top Vial 9. 1 x 3mL Mobile phase additiveAqueous Ammonia Specific Gravity - 0.88 to 0.89 (~30% w/w ammonia) Flame sealed ampule 10. 2 x 1mL Mobile phase additive: Formic Acid 98-100% Purity Flame sealed ampule 1 X 715001937 Solution Prep – Xevo TQ Document 1 Clear Nalgene Bottle 30ml Certificate of Analysis
Part Number: 700004045
Brand: Xevo
Application System Calibration, System Performance
Detection Method MS
Formulation Liquid, Solid
Product Type Standards
Shelf Life 12 Months
Shipping Ambient
Storage 4 C (Fridge)
System Type MS
Type Reference
Units per Package 1 pk
Tip Seal Kit XDS35i / XDS100B - 6061146-S
SKU: 6061146-S
Tip Seal Kit XDS35i / XDS100B - 6061146-S
List Price
$575.00
Category: Service Parts & Kits
Tip Seal Kit XDS35i / XDS100B - 6061146-S: The Tip Seal Kit is part of the vacuum components on the Scroll Pump XDS35i.
Part Number: 6061146-S
Brand: Waters Quality Parts
Replacement Schedule Annual
Units per Package 1 pk
UV Detector PQ Standard - WAT042887
SKU: WAT042887
UV Detector PQ Standard - WAT042887
List Price
$82.00
Category: Standards & Reagents
UV Detector PQ Standard - WAT042887: Kit contains standards appropriate for assessment of HPLC UV systems. 1 Ampule (10 mL standard solution contains): - 10.00 mg/L Acetophenone (+/- 5%) Purity > 99% - 10.00 mg/L Propiophenone (+/- 5%) Purity > 99% - 10.00 mg/L Butyrophenone (+/- 5%) Purity > 99% - 3.2 g/L Acetone (+/- 5%) Purity > 99.74% Solution in 60% HPLC Grade Methanol / 40% HPLC Grade Water, volume/volume.
Part Number: WAT042887
Application System Performance
Detection Method UV
Formulation Liquid
Product Type Standards
Quantitative Yes
Separation Mode Reversed Phase
Shelf Life 24 Months
Shipping Ambient
Storage Room Temperature
System Type LC
Tolarence 0.05
Type Reference
Units per Package 1 pk
Volume 10 mL
ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk - 186006937
SKU: 186006937
ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk - 186006937
List Price
$985.00
Category: Columns
ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1K - 15K, 1/pk - 186006937: Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.
Part Number: 186006937
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
High Pressure Motorized Valve Assembly - WAT045438
SKU: WAT045438
High Pressure Motorized Valve Assembly - WAT045438
List Price
$3210.00
Category: Service Parts & Kits
High Pressure Motorized Valve Assembly - WAT045438: The High Pressure Motorized Valve (HPMV) is a three-way valve that has two common ports and one controllable port. The HPMV is used in two of the three valve positions in the Fluids Pak: V1 (High Pressure Inject Valve) and V2 (High Pressure Syringe Valve). The basic valve is driven by a stepper motor. Used on 717 PLUS Autosamplers and Alliance 2695 & 2695D Separation Modules.
Part Number: WAT045438
Brand: Waters Quality Parts
Replacement Schedule As Required
System HPLC
Type Valve
Units per Package 1 pk
2-AB Glycan Performance Test Standard - 186006349
SKU: 186006349
2-AB Glycan Performance Test Standard - 186006349
List Price
$1150.00
Category: Standards & Reagents
2-AB Glycan Performance Test Standard - 186006349: The 2-AB Glycan Performance Test Standard is 2-AB labeled Human IgG and is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC BEH Glycan, 1.7 µm Columns. It comes in a Waters TruView vial as a lyophilized powder. There is 228 pmol total/vial. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.
Part Number: 186006349
Application Glycan
Detection Method UV
Formulation Solid
Product Type Standards
Separation Mode HILIC
Shelf Life 12 Months
Shelf life upon reconstitution 1 Week
Shipping Ambient
Storage -20 C (Freezer)
System Type LC
Type Reference
Units per Package 1 pk
Flowcell, ACQUITY PDA, 5 mm, SS - 205000612
SKU: 205000612
Flowcell, ACQUITY PDA, 5 mm, SS - 205000612
List Price
$4700.00
Category: Service Parts & Kits
Flowcell, ACQUITY PDA, 5 mm, SS - 205000612: ACQUITY PDA 5mm SS Flow cell
Part Number: 205000612
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC PDA Detector
Replacement Schedule As Needed
Sep-Pak tC18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37 - 55 µm, 100/pk - WAT036820
SKU: WAT036820
Sep-Pak tC18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37 - 55 µm, 100/pk - WAT036820
List Price
$185.00
Category: Sample Preparation & Filtration
Sep-Pak tC18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37 - 55 µm, 100/pk - WAT036820: Silica-based bonded phase with strong hydrophobicity; trifunctional bonding chemistry gives it an increased hydrolytic stabilty; applications similar to C18.
Part Number: WAT036820
Brand: Sep-Pak
Barrel Size 1 cc
Chemistry tC18
Endcapped Yes
Format Vac Cartridge
Hold up volume 0.25 mL
Mass Spec Compatibility Yes
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125 Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units per Package 100 pk
Water Wettable No
pH Range Max 8 pH
pH Range Min 2 pH
Empower 3 Personal GPC/SEC - 667003977
SKU: 667003977
Empower 3 Personal GPC/SEC - 667003977
List Price
$3290.00
Category: Software
Empower 3 Personal GPC/SEC - 667003977: Gel permeation chromatography (GPC) is an analytical technique that separates molecules by size. The GPC option includes the calculation of all typical GPC results such as Mw, Mn, Mp, Mz, Mz+1. Creates GPC calibration curves and translates GPC data to molecular weight and easy to interpret distribution plots.
Part Number: 667003977
Brand: Empower
Product Compatibility Empower 3 all versions
Quantity 1
Back Pressure Restrictor - 700009590
SKU: 700009590
Back Pressure Restrictor - 700009590
List Price
$205.00
Category: Service Parts & Kits
Back Pressure Restrictor - 700009590: ACQUITY Back Pressure Restrictor
Part Number: 700009590
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY PDA (Taperslit) Detectors
Replacement Schedule As Needed
ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186003685
SKU: 186003685
ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186003685
List Price
$965.00
Category: Columns
ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186003685: The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
Part Number: 186003685
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
System UHPLC, UPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk - WAT044380
SKU: WAT044380
Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk - WAT044380
List Price
$340.00
Category: Columns
Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pk - WAT044380: Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.
Part Number: WAT044380
Brand: Nova-Pak
Carbon Load 7 %
Chemistry C18
Endcapped Yes
Format Guard Column
Inner Diameter 3.9 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 4 µm
Particle Substrate Silica
Pore Size 60 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 8 pH
Symmetry C18 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pk - 186007731
SKU: 186007731
Symmetry C18 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pk - 186007731
List Price
$420.00
Category: Columns
Symmetry C18 VanGuard Cartridge, 100Å, 5 µm, 3.9 mm X 5 mm, 3/pk - 186007731: Symmetry C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. Symmetry C18 analytical columns containing 5 µm sorbent particles.
Part Number: 186007731
Brand: Symmetry
Carbon Load 19 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 3.9 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 110
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 8 pH
XSelect HSS C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pk - 186008222
SKU: 186008222
XSelect HSS C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pk - 186008222
List Price
$1245.00
Category: Columns
XSelect HSS C18 OBD Prep Column, 100Å, 5 µm, 10 mm X 50 mm, 1/pk - 186008222: The HSS C18 is a general-purpose C18 bonded phase column that provides superior peak shape for bases, increased retention (vs. XBridge C18 columns), and exceptional column lifetimes at low pH. The selectivity and retention observed with HSS C18 columns will resemble that of most modern, fully endcapped, high-coverage silica-based C18 columns.
Part Number: 186008222
Brand: XSelect
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 10 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
IC-Pak Ion-Exclusion Column, 7 µm, 7.8 mm x 300 mm, 1/pk - WAT010290
SKU: WAT010290
IC-Pak Ion-Exclusion Column, 7 µm, 7.8 mm x 300 mm, 1/pk - WAT010290
List Price
$1560.00
Category: Columns
IC-Pak Ion-Exclusion Column, 7 µm, 7.8 mm x 300 mm, 1/pk - WAT010290: IC-Pak Ion Exclusion columns are used for the analysis of weak acid anions such as fluoride and short chain organic acids from formate to butyrate.
Part Number: WAT010290
Brand: IC-Pak
Chemistry Ion Exclusion
Endfitting Type Waters
Format Column
Inner Diameter 7.8 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 7 µm
Product Type Columns
Separation Mode Ion-Exclusion
System HPLC
Units per Package 1 pk
RCM 8X10 Cartridge Holder - WAT082887
SKU: WAT082887
RCM 8X10 Cartridge Holder - WAT082887
List Price
$431.00
Category: Service Parts & Kits
Buy RCM 8X10 Cartridge Holder - WAT082887 from Waters
Part Number: WAT082887
Probe Adjuster Assembly (LCZ/ZMD/Ultima) - 700000436
SKU: 700000436
Probe Adjuster Assembly (LCZ/ZMD/Ultima) - 700000436
List Price
$9900.00
Category: Service Parts & Kits
Probe Adjuster Assembly (LCZ/ZMD/Ultima) - 700000436: This spare part is a Waters Quality part
Part Number: 700000436
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Q-Tof micro Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed
PIC B8 Low UV Reagent - WAT084283
SKU: WAT084283
PIC B8 Low UV Reagent - WAT084283
List Price
$218.00
Category: Standards & Reagents
PIC B8 Low UV Reagent - WAT084283: Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B8 low UV is a 5 vial/pkg of octane sulfonic acid in a workable UV range in mobile phase 200+ nm.
Part Number: WAT084283
Detection Method UV
Formulation Liquid
Product Type Reagents
Separation Mode Reversed Phase
Shipping Ambient
Storage Room Temperature
System Type LC
Type Reagent
Units per Package 5 pk
Volume 15 mL
XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005270
SKU: 186005270
XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005270
List Price
$930.00
Category: Columns
XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005270: XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.
Part Number: 186005270
Brand: XSelect
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554
SKU: 186002554
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554
List Price
$790.00
Category: Columns
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002554
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
i2V Assembly, BioACQUITY - 700005412
SKU: 700005412
i2V Assembly, BioACQUITY - 700005412
List Price
$1150.00
Category: Service Parts & Kits
i2V Assembly, BioACQUITY - 700005412: Replacement i2V assembly. Used on H-Class Bio Quaternary Solvent Managers and M-Class Binary and Auxilliary Solvent Managers.
Part Number: 700005412
PM Kit No
Part Category Check Valves
Product Category ACQUITY
nanoACQUITY
Products ACQUITY H-Class Bio Quaternary Solvent Manager
ACQUITY M-Class µASM
ACQUITY M-Class µBSM
Replacement Schedule As Needed
Spherisorb C8 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pk - PSS831813
SKU: PSS831813
Spherisorb C8 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pk - PSS831813
List Price
$585.00
Category: Columns
Spherisorb C8 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pk - PSS831813: Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.
Part Number: PSS831813
Brand: Spherisorb
Carbon Load 6 %
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 80 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 8 pH
Solvent Bottle Filter, 7/pk - 700003616
SKU: 700003616
Solvent Bottle Filter, 7/pk - 700003616
List Price
$610.00
Category: Service Parts & Kits
Solvent Bottle Filter, 7/pk - 700003616: The Solvent Bottle Filter is a critical clean part made of stainless steel material. The original part number was 700002824 and it has been changed to p/n 700003616.
Part Number: 700003616
Brand: Waters Quality Parts
Material Stainless Steel
Replacement Schedule Annual
System HPLC, UPC2, UPLC
Type Filter - Solvent
Units per Package 7 pk
Glycoworks RapiFluor-MS N-Glycan Starter Kit-24 sample - 176003712
SKU: 176003712
Glycoworks RapiFluor-MS N-Glycan Starter Kit-24 sample - 176003712
List Price
$3296.00
Category: Application Kits
Glycoworks RapiFluor-MS N-Glycan Starter Kit-24 sample - 176003712: Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in as little as 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS's (RFMS) unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive. This starter kit includes the GlycoWorks Deglycosylation Module, GlycoWorks Labeling Module, GlycoWorks Clean-up Module, GlycoWorks Sample Collection Module, as well as the ACQUITY UPLC Glycan BEH Amide, 1.7 µm, 2.1 x 150 Column and Mobile-Phase Concentrate: Ammonium Formate. It contains materials to process 24 samples in a 3x8 format. The kit contains: GlycoWorks Deglycosylation Module: (1) 0.035 ml/vial Rapid PNGaseF Enzyme (1) 0.25 ml/vial Glycoworks Rapid Buffer (1) 3 vials of 3 mg/vial RapiGest™ SF Surfactant (1) Intact mAb Mass Check Standard *Shipped in a separate box GlycoWorks RapiFluor-MS Labeling Module: (3) 9 mg/vial RapiFluor-MS Reagent (3) 1 mL/vial Reagent Solvent (Anhydrous DMF) GlycoWorks RFMS Clean-up Module: (4) 0.5 ml/vial Elution Buffer (200mM Ammonium Acetate 95/5 Water/ACN pH 7) (4) 3 ml/vial Sample Diluent (DMF/ACN Mixture) (1) GlycoWorks HILIC µElution Plate GlycoWorks Sample Collection Module: (15) 1 mL tubes for deglycosylation and labeling reaction (15) 600 µL tube inserts for SPE eluate collection (15) Cap strips with slits for direct injection (1) 1 mL round collection tray (1) Waste tray In Addition To: (1) 5050 mM Ammonium Formate Solution—Glycan Analysis (186007081) (1) ACQUITY UPLC Glycan BEH Amide Column, 130A, 1.7ìm, 2.1 x 150 mm (186004742) y
Part Number: 176003712
Brand: GlycoWorks
Application Glycan
Detection Method HRMS, MS, MS/MS, UV
Number of Analysis 24
Packages per kit 7
Product Type Application Kits
Separation Mode HILIC
Shelf Life Refer to the storage recommendations of each sub-package
Storage Refer to the storage recommendations of each sub-package
System Type LC-MS
Type Sample Preparation Workflow
Units per Package 1 pk
Flowcell, ACQUITY TUV, 5 mm, SS - 205000610
SKU: 205000610
Flowcell, ACQUITY TUV, 5 mm, SS - 205000610
List Price
$4700.00
Category: Service Parts & Kits
Flowcell, ACQUITY TUV, 5 mm, SS - 205000610: This new stainless steel flowcell will fit into existing ACQUITY TUV Detectors with serial number K05UPT700N and above. The fluidic connections will be the same as for the existing flowcells. The new flowcell has a robust design and has a decreased pathlength of 5mm.
Part Number: 205000610
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC TUV Detector
Replacement Schedule As Needed
Synthetic Vacuum Pump Oil - 700011138
SKU: 700011138
Synthetic Vacuum Pump Oil - 700011138
Category: Service Parts & Kits
Synthetic Vacuum Pump Oil - 700011138: Synthetic Vacuum Pump Oil
Part Number: 700011138
Brand: Waters Quality Parts
Replacement Schedule Annual
System MS
Type Lubricant
Units per Package 1 pk
Volume 1 L