Product Listing:  XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 186007264 to Viridis BEH Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186006544

XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 186007264
SKU: 186007264
XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 186007264
List Price
$910.00
Category: Columns
XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pk - 186007264: Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.
Part Number: 186007264
Brand: XBridge
Application Glycan
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format XP Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 150000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Glycan
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity Low
Surface Area 185
System UHPLC
USP Classification L68
Units per Package 1 pk
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk - 176001915
SKU: 176001915
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk - 176001915
List Price
$2535.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 1 mm X 100 mm, 3/pk - 176001915: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 176001915
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1K - 30K, 1/pk - 186005657
SKU: 186005657
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1K - 30K, 1/pk - 186005657
List Price
$930.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 75 mm, 1K - 30K, 1/pk - 186005657: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 186005657
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 75 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 1 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk - 176001906
SKU: 176001906
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk - 176001906
List Price
$2430.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 30 mm, 3/pk - 176001906: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 176001906
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 30 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 176001909
SKU: 176001909
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 176001909
List Price
$2660.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 176001909: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 176001909
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 176001907
SKU: 176001907
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 176001907
List Price
$2485.00
Category: Columns
ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pk - 176001907: ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.
Part Number: 176001907
Brand: ACQUITY UPLC
Carbon Load 12 %
Chemistry Amide
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 185
System UHPLC, UPLC
USP Classification L68
Units per Package 3 pk
eCord Yes
pH Range 11 pH
µBondapak C18 Cartridge, 125Å, 10 µm, 4.6 mm X 250 mm, 1/pk - WAT052860
SKU: WAT052860
µBondapak C18 Cartridge, 125Å, 10 µm, 4.6 mm X 250 mm, 1/pk - WAT052860
List Price
$750.00
Category: Columns
µBondapak C18 Cartridge, 125Å, 10 µm, 4.6 mm X 250 mm, 1/pk - WAT052860: µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.
Part Number: WAT052860
Brand: µBondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Cartridge
Inner Diameter 4.6 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Cartridge Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084040
SKU: WAT084040
µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084040
List Price
$765.00
Category: Columns
µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084040: If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.
Part Number: WAT084040
Brand: µBondapak
Carbon Load 4 %
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Normal-Phase
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L8
Units per Package 1 pk
pH Range 8 pH
ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006516
SKU: 186006516
ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006516
List Price
$3105.00
Category: Columns
ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 186006516: The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
Part Number: 186006516
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
ACQUITY UPLC Peptide CSH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 176003068
SKU: 176003068
ACQUITY UPLC Peptide CSH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 176003068
List Price
$3230.40
Category: Columns
ACQUITY UPLC Peptide CSH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pk - 176003068: Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit consists of three ACQUITY UPLC CSH130 C18 columns packed with three different batches of sorbent and and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003068
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Method Validation Kit
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
ACQUITY UPLC Peptide CSH C18 Column Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 176003066
SKU: 176003066
ACQUITY UPLC Peptide CSH C18 Column Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 176003066
List Price
$1171.83
Category: Columns
ACQUITY UPLC Peptide CSH C18 Column Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 176003066: Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one ACQUITY UPLC CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.
Part Number: 176003066
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column Kit
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Column Kits
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pk - 186007471
SKU: 186007471
ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pk - 186007471
List Price
$445.00
Category: Columns
ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pk - 186007471: ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. As the 75µm to 180µm ID columns are fritted with a novel frit technology, they are able to withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.
Part Number: 186007471
Brand: ACQUITY UPLC M-Class
Application Peptide
Carbon Load 18 %
Chemistry C18
Endfitting Type Parker-style
Format Trap Column
Inner Diameter 300 µm
Length 50 mm
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pk - 186007472
SKU: 186007472
ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pk - 186007472
List Price
$800.00
Category: Columns
ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pk - 186007472: ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. As the 75µm to 180µm ID columns are fritted with a novel frit technology, they are able to withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.
Part Number: 186007472
Brand: ACQUITY UPLC M-Class
Application Peptide
Bonding Technology T3
Carbon Load 11 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 300 µm
Length 150 mm
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 230
System Nano/Micro
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
ACQUITY UPLC M-Class Peptide BEH C18 Column, 300Å, 1.7 µm, 75 µm X 200 mm, 1/pk - 186007491
SKU: 186007491
ACQUITY UPLC M-Class Peptide BEH C18 Column, 300Å, 1.7 µm, 75 µm X 200 mm, 1/pk - 186007491
List Price
$815.00
Category: Columns
ACQUITY UPLC M-Class Peptide BEH C18 Column, 300Å, 1.7 µm, 75 µm X 200 mm, 1/pk - 186007491: ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.
Part Number: 186007491
Brand: ACQUITY UPLC M-Class
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Valco(male)|360um Open
Format Column
Inner Diameter 75 µm
Length 200 mm
Maximum Pressure 15000 psi (1034 bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System Nano/Micro
USP Classification L1
Units per Package 1 pk
pH Range 10 pH
ACQUITY UPLC M-Class Peptide BEH C18 Column, 300Å, 1.7 µm, 75 µm X 100 mm, 1/pk - 186007487
SKU: 186007487
ACQUITY UPLC M-Class Peptide BEH C18 Column, 300Å, 1.7 µm, 75 µm X 100 mm, 1/pk - 186007487
List Price
$660.00
Category: Columns
ACQUITY UPLC M-Class Peptide BEH C18 Column, 300Å, 1.7 µm, 75 µm X 100 mm, 1/pk - 186007487: ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.
Part Number: 186007487
Brand: ACQUITY UPLC M-Class
Application Peptide
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Valco(male)|360um Open
Format Column
Inner Diameter 75 µm
Length 100 mm
Maximum Pressure 15000 psi (1034 bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 90
System Nano/Micro
USP Classification L1
Units per Package 1 pk
pH Range 10 pH
ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pk - 186007483
SKU: 186007483
ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pk - 186007483
List Price
$815.00
Category: Columns
ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pk - 186007483: ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.
Part Number: 186007483
Brand: ACQUITY UPLC M-Class
Application Peptide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Valco(male)|360um Open
Format Column
Inner Diameter 75 µm
Length 200 mm
Maximum Pressure 15000 psi (1034 bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System Nano/Micro
USP Classification L1
Units per Package 1 pk
pH Range 10 pH
1/4 in Ball Valve, angled - 6062327
SKU: 6062327
1/4 in Ball Valve, angled - 6062327
List Price
$390.00
Category: Service Parts & Kits
1/4 in Ball Valve, angled - 6062327: This spare part is a Waters Quality part
Part Number: 6062327
PM Kit No
Part Category Valves
Product Category Mass Spectrometry
Products Quattro micro GC Mass Spectrometer
Replacement Schedule As Needed
XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk - 186003952
SKU: 186003952
XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk - 186003952
List Price
$865.00
Category: Columns
XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk - 186003952: Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.
Part Number: 186003952
Brand: XBridge
Application Oligonucleotide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Oligonucleotide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
Sirocco Protein Precipitation Plate, 5/pk - 186002448
SKU: 186002448
Sirocco Protein Precipitation Plate, 5/pk - 186002448
List Price
$611.00
Category: Sample Preparation & Filtration
Sirocco Protein Precipitation Plate, 5/pk - 186002448: Waters, in collaboration with Pall Life Sciences, is pleased to introduce our new Protein Precipitation Plate — Sirocco™. The most technologically advanced protein precipitation plate on the market. The Sirocco™ Plate enables high-throughput “in-well” protein precipitation of biological samples without the fear of cloudy filtrates or clogged devices. This plate contains a unique filter system, a sealing cap mat and a patented valve technology designed specifically to allow “in-well” processing which prevents clogged wells, cross-talk or leaking during use. The Sirocco™ Protein Precipitation Plate provides optimum performance in faster processing time by reducing steps in ‘in-well’ sample processing and complete recovery of clean filtrate from smaller plasma sample volumes.
Part Number: 186002448
Brand: Sirocco
Format 96-well Plate
Mass Spec Compatibility Yes
Material Polypropylene
Mode Precipitation
Number of Wells 96
Product Type Protein Precipitation
Units per Package 5 pk
Acrodisc, Minispike Syringe Filter, PTFE, 13 mm, 0.45 µm, Non polar, 1000/case - WAT200825
SKU: WAT200825
Acrodisc, Minispike Syringe Filter, PTFE, 13 mm, 0.45 µm, Non polar, 1000/case - WAT200825
List Price
$1251.00
Category: Sample Preparation & Filtration
Acrodisc, Minispike Syringe Filter, PTFE, 13 mm, 0.45 µm, Non polar, 1000/case - WAT200825: This PTFE membrane is a good choice for use with aggresive organic solvents
Part Number: WAT200825
Brand: Acrodisc
Diameter 13 mm
Filter Type PTFE
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Material Polypropylene
Pore Size 0.45 µm
Product Type Filtration
Sample Volume < 10 mL
Separation Mode Non polar
Units per Package 1000 case
Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pk - WAT200516
SKU: WAT200516
Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pk - WAT200516
List Price
$268.00
Category: Sample Preparation & Filtration
Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pk - WAT200516: GHP has the broadest chemical compatibility and exhibits minimal protein binding
Part Number: WAT200516
Brand: Acrodisc
Diameter 13 mm
Filter Type GHP
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Material Polypropylene
Pore Size 0.45 µm
Product Type Filtration
Sample Volume < 10 mL
Separation Mode Aqueous
Units per Package 100 pk
Sep-Pak Accell Plus QMA 96-well Plate, 100 mg Sorbent per Well, 37 - 55 µm, 1/pk - 186001917
SKU: 186001917
Sep-Pak Accell Plus QMA 96-well Plate, 100 mg Sorbent per Well, 37 - 55 µm, 1/pk - 186001917
List Price
$474.00
Category: Sample Preparation & Filtration
Sep-Pak Accell Plus QMA 96-well Plate, 100 mg Sorbent per Well, 37 - 55 µm, 1/pk - 186001917: Sep-Pak Accell Plus QMA Plus well plates contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These versatile cartridges can attach easily to pumps and syringes for reliable, positive-pressure flow to speed up the sample processing time. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.
Part Number: 186001917
Brand: Sep-Pak
Carbon Load 6 %
Chemistry Accell Plus QMA
Endcapped No
Format 96-well Plate
Ion Exchange Capacity 230 µeq/gram
Mass Spec Compatibility Yes
Material Polypropylene
Mode Ion-Exchange
Number of Wells 96
Particle Size 37-55 µm
Pore Size 300 Å
Product Type Solid Phase Extraction
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units per Package 1 pk
Water Wettable No
pH Range Max 8 pH
pH Range Min 2 pH
Sep-Pak Accell Plus QMA Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37 - 55 µm, 50/pk - WAT020545
SKU: WAT020545
Sep-Pak Accell Plus QMA Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37 - 55 µm, 50/pk - WAT020545
List Price
$216.00
Category: Sample Preparation & Filtration
Sep-Pak Accell Plus QMA Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37 - 55 µm, 50/pk - WAT020545: Sep-Pak Accell Plus QMA Plus Short cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These versatile cartridges can attach easily to pumps and syringes for reliable, positive-pressure flow to speed up the sample processing time. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.
Part Number: WAT020545
Brand: Sep-Pak
Chemistry Accell Plus QMA
Format Plus Short Cartridge
Hold up volume 0.8 mL
Ion Exchange Capacity 230 µeq/gram
Mass Spec Compatibility Yes
Mode Ion-Exchange
Particle Size 37-55 µm
Pore Size 300 Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units per Package 50 pk
Water Wettable Yes
pH Range Max 8 pH
pH Range Min 2 pH
Shodex SP-G Guard Column, 8 µm, 6 mm x 50 mm, 1/pk - WAT034245
SKU: WAT034245
Shodex SP-G Guard Column, 8 µm, 6 mm x 50 mm, 1/pk - WAT034245
List Price
$525.00
Category: Columns
Shodex SP-G Guard Column, 8 µm, 6 mm x 50 mm, 1/pk - WAT034245: Shodex® high performance polymeric columns for sugar analysis
Part Number: WAT034245
Brand: Shodex
Endfitting Type Parker-style
Format Guard Column
Inner Diameter 6 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Packing Solvent Water
Particle Shape Spherical
Particle Size 8 µm
Particle Substrate Polymer
Product Type Guards
System HPLC
Units per Package 1 pk
pH Range 12 pH
Shodex SH-G Guard Column, 7 µm, 6 mm x 50 mm, 1/pk - WAT034243
SKU: WAT034243
Shodex SH-G Guard Column, 7 µm, 6 mm x 50 mm, 1/pk - WAT034243
List Price
$525.00
Category: Columns
Shodex SH-G Guard Column, 7 µm, 6 mm x 50 mm, 1/pk - WAT034243: Shodex® high performance polymeric columns for sugar analysis
Part Number: WAT034243
Brand: Shodex
Endfitting Type Parker-style
Format Guard Column
Inner Diameter 6 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Packing Solvent Water
Particle Shape Spherical
Particle Size 7 µm
Particle Substrate Polymer
Product Type Guards
System HPLC
Units per Package 1 pk
pH Range 12 pH
Quick Load Replacement Inserts for 96-well Plate, 1 mL, 1/pk - 186001436
SKU: 186001436
Quick Load Replacement Inserts for 96-well Plate, 1 mL, 1/pk - 186001436
List Price
$68.00
Category: Vials, Containers, & Collection Plates
Quick Load Replacement Inserts for 96-well Plate, 1 mL, 1/pk - 186001436: Vial inserts are a solution in applications where there is limited sample volume. Choose the appropriate volume insert for your sample volume and vial size.
Part Number: 186001436
Application Sample Preparation
Format 96-Well Plate
Material Glass insert
Number of Wells 96
Product Type Accessories
Units per Package 1 pk
Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pk - 186005739
SKU: 186005739
Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pk - 186005739
List Price
$12280.00
Category: Columns
Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pk - 186005739: Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.
Part Number: 186005739
Brand: Viridis
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode SuperCritical Fluid (SFC)
Silanol Activity Medium
Surface Area 185
System SFC Preparative
Technique SFC, SFC/MS
Units per Package 1 pk
Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186005737
SKU: 186005737
Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186005737
List Price
$5575.00
Category: Columns
Viridis BEH OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pk - 186005737: Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.
Part Number: 186005737
Brand: Viridis
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 30 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode SuperCritical Fluid (SFC)
Silanol Activity Medium
Surface Area 185
System SFC Preparative
Technique SFC, SFC/MS
Units per Package 1 pk
Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186005741
SKU: 186005741
Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186005741
List Price
$9580.00
Category: Columns
Viridis BEH OBD Prep Column, 130Å, 5 µm, 50 mm X 100 mm, 1/pk - 186005741: Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.
Part Number: 186005741
Brand: Viridis
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 50 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode SuperCritical Fluid (SFC)
Silanol Activity Medium
Surface Area 185
System SFC Preparative
Technique SFC, SFC/MS
Units per Package 1 pk
Viridis BEH Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186006544
SKU: 186006544
Viridis BEH Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186006544
List Price
$855.00
Category: Columns
Viridis BEH Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186006544: Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.
Part Number: 186006544
Brand: Viridis
Endcapped No
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode SuperCritical Fluid (SFC)
Silanol Activity Medium
Surface Area 185
System SFC, UPC2
Technique SFC, SFC/MS
Units per Package 1 pk