Product Listing:  Atlantis dC18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186001299 to Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT035876

Atlantis dC18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186001299
SKU: 186001299
Atlantis dC18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186001299
List Price
$790.00
Category: Columns
Atlantis dC18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186001299: Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186001299
Brand: Atlantis
Bonding Technology dC18
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 7 pH
Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pk - 186003729
SKU: 186003729
Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pk - 186003729
List Price
$790.00
Category: Columns
Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pk - 186003729: Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Part Number: 186003729
Brand: Atlantis
Bonding Technology T3
Carbon Load 14 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554
SKU: 186002554
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554
List Price
$790.00
Category: Columns
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002554
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002732
SKU: 186002732
SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002732
List Price
$790.00
Category: Columns
SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002732: SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.
Part Number: 186002732
Brand: SunFire
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 8 pH
Atlantis dC18 Column, 100Å, 3 µm, 3.9 mm X 150 mm, 1/pk - 186001317
SKU: 186001317
Atlantis dC18 Column, 100Å, 3 µm, 3.9 mm X 150 mm, 1/pk - 186001317
List Price
$790.00
Category: Columns
Atlantis dC18 Column, 100Å, 3 µm, 3.9 mm X 150 mm, 1/pk - 186001317: Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186001317
Brand: Atlantis
Bonding Technology dC18
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 7 pH
Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186003719
SKU: 186003719
Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186003719
List Price
$790.00
Category: Columns
Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pk - 186003719: Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Part Number: 186003719
Brand: Atlantis
Bonding Technology T3
Carbon Load 14 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Atlantis dC18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186001344
SKU: 186001344
Atlantis dC18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186001344
List Price
$775.00
Category: Columns
Atlantis dC18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186001344: Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186001344
Brand: Atlantis
Bonding Technology dC18
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 7 pH
SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186002559
SKU: 186002559
SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186002559
List Price
$775.00
Category: Columns
SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186002559: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002559
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Atlantis dC18 Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186001301
SKU: 186001301
Atlantis dC18 Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186001301
List Price
$775.00
Category: Columns
Atlantis dC18 Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186001301: Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186001301
Brand: Atlantis
Bonding Technology dC18
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 7 pH
Atlantis HILIC Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186002016
SKU: 186002016
Atlantis HILIC Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186002016
List Price
$775.00
Category: Columns
Atlantis HILIC Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pk - 186002016: Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.
Part Number: 186002016
Brand: Atlantis
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Silica
Particle Technology Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L3
Units per Package 1 pk
pH Range 5 pH
Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pk - WAT066224
SKU: WAT066224
Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pk - WAT066224
List Price
$770.00
Category: Columns
Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pk - WAT066224: Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.
Part Number: WAT066224
Brand: Symmetry
Carbon Load 19 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
XTerra MS C18 Column, 125Å, 5 µm, 3 mm X 100 mm, 1/pk - 186000466
SKU: 186000466
XTerra MS C18 Column, 125Å, 5 µm, 3 mm X 100 mm, 1/pk - 186000466
List Price
$770.00
Category: Columns
XTerra MS C18 Column, 125Å, 5 µm, 3 mm X 100 mm, 1/pk - 186000466: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000466
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084042
SKU: WAT084042
µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084042
List Price
$765.00
Category: Columns
µBondapak Cyano (CN) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084042: If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.
Part Number: WAT084042
Brand: µBondapak
Carbon Load 6 %
Chemistry Cyano (CN)
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L10
Units per Package 1 pk
pH Range 8 pH
µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084040
SKU: WAT084040
µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084040
List Price
$765.00
Category: Columns
µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pk - WAT084040: If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.
Part Number: WAT084040
Brand: µBondapak
Carbon Load 4 %
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 300 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Normal-Phase
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L8
Units per Package 1 pk
pH Range 8 pH
µBondapak C18 Cartridge, 125Å, 10 µm, 4.6 mm X 250 mm, 1/pk - WAT052860
SKU: WAT052860
µBondapak C18 Cartridge, 125Å, 10 µm, 4.6 mm X 250 mm, 1/pk - WAT052860
List Price
$750.00
Category: Columns
µBondapak C18 Cartridge, 125Å, 10 µm, 4.6 mm X 250 mm, 1/pk - WAT052860: µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.
Part Number: WAT052860
Brand: µBondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Cartridge
Inner Diameter 4.6 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Cartridge Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pk - 186001337
SKU: 186001337
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pk - 186001337
List Price
$735.00
Category: Columns
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pk - 186001337: Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186001337
Brand: Atlantis
Bonding Technology dC18
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 7 pH
ACQUITY UPLC CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186005303
SKU: 186005303
ACQUITY UPLC CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186005303
List Price
$735.00
Category: Columns
ACQUITY UPLC CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186005303: ACQUITY CSH C18 columns were designed to provide alternate selectivity compared to other reversed-phase UPLC columns. These ultra-efficient columns overcome peak shape asymmetry and poor loading capacity for basic compounds, column bleed, and rapid mobile-phase re-equilibration. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186005303
Brand: ACQUITY UPLC
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 11 pH
ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk - 186003976
SKU: 186003976
ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk - 186003976
List Price
$735.00
Category: Columns
ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pk - 186003976: The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186003976
Brand: ACQUITY UPLC
Bonding Technology T3
Carbon Load 11 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
pH Range 8 pH
Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1/pk - 186003718
SKU: 186003718
Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1/pk - 186003718
List Price
$735.00
Category: Columns
Atlantis T3 Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1/pk - 186003718: Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.
Part Number: 186003718
Brand: Atlantis
Bonding Technology T3
Carbon Load 14 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003975
SKU: 186003975
ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003975
List Price
$735.00
Category: Columns
ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pk - 186003975: As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186003975
Brand: ACQUITY UPLC
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
Atlantis HILIC Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1/pk - 186002013
SKU: 186002013
Atlantis HILIC Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1/pk - 186002013
List Price
$735.00
Category: Columns
Atlantis HILIC Column, 100Å, 3 µm, 2.1 mm X 100 mm, 1/pk - 186002013: Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.
Part Number: 186002013
Brand: Atlantis
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Particle Technology Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Hydrophilic Interaction (HILIC)
Silanol Activity High
Surface Area 330
System HPLC
USP Classification L3
Units per Package 1 pk
pH Range 5 pH
ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 10K - 500K, 3/pk - 186004623
SKU: 186004623
ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 10K - 500K, 3/pk - 186004623
List Price
$735.00
Category: Columns
ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 10K - 500K, 3/pk - 186004623: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.
Part Number: 186004623
Brand: ACQUITY UPLC
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Direct-Connect
Format VanGuard Pre-column
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Molecular Weight Range Max 500000
Molecular Weight Range Min 10000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Guards
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
System UHPLC, UPLC
USP Classification L26
Units per Package 3 pk
pH Range 12 pH
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 186002553
SKU: 186002553
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 186002553
List Price
$735.00
Category: Columns
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pk - 186002553: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002553
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 186003607
SKU: 186003607
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 186003607
List Price
$715.00
Category: Columns
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 186003607: The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
Part Number: 186003607
Brand: XBridge
Application Peptide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
AccQ-Tag Ultra Derivatization Kit - 186003836
SKU: 186003836
AccQ-Tag Ultra Derivatization Kit - 186003836
List Price
$700.00
Category: Application Kits
AccQ-Tag Ultra Derivatization Kit - 186003836: Amino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Derivitization Kit is a component of the UPLC® Amino Acid Analysis Application Solution. This kit is executed with UV detection and is enough for 250 anaylses.
Part Number: 186003836
Brand: AccQ-Tag
Application Amino Acid Analysis
Product Type Application Kits
AccQ-Fluor Reagent Kit - WAT052880
SKU: WAT052880
AccQ-Fluor Reagent Kit - WAT052880
List Price
$623.00
Category: Application Kits
AccQ-Fluor Reagent Kit - WAT052880: Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag-Fluor Reagent Pkg Includes: AccQTagFluor Reagent 1, 5X 6mL Vials Reagent 2A 5 X 3 mg vials, AccQFluor Reagent 2B 5 X 4mL vials. The components of this kit are not available separately.
Part Number: WAT052880
Brand: AccQ-Fluor
Application Amino Acid Analysis
Detection Method Optical
Product Type Application Kits
Separation Mode Reverse phase
Shelf life upon reconstitution 1 Week
System Type LC
Type Reagent
Units per Package 1 pk
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 75 mm, 1/pk - 186001333
SKU: 186001333
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 75 mm, 1/pk - 186001333
List Price
$690.00
Category: Columns
Atlantis dC18 Column, 100Å, 3 µm, 4.6 mm X 75 mm, 1/pk - 186001333: Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.
Part Number: 186001333
Brand: Atlantis
Bonding Technology dC18
Carbon Load 12 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 75 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 7 pH
Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT086344
SKU: WAT086344
Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT086344
List Price
$665.00
Category: Columns
Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT086344: Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.
Part Number: WAT086344
Brand: Nova-Pak
Carbon Load 7 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 4 µm
Particle Substrate Silica
Pore Size 60 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT010656
SKU: WAT010656
Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT010656
List Price
$665.00
Category: Columns
Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT010656: Nova-Pak HP Phenyl columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.
Part Number: WAT010656
Brand: Nova-Pak
Bonding Technology Phenyl-Hexyl
Carbon Load 5 %
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 4 µm
Particle Substrate Silica
Pore Size 60 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L11
Units per Package 1 pk
pH Range 8 pH
Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT035876
SKU: WAT035876
Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT035876
List Price
$665.00
Category: Columns
Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk - WAT035876: Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.
Part Number: WAT035876
Brand: Nova-Pak
Carbon Load 4 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 4 µm
Particle Substrate Silica
Pore Size 60 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 8 pH