Product Listing:  RCM 8X10 Cartridge Holder - WAT082887 to Sep-Pak C18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 55 - 105 µm, 30/pk - WAT043395

RCM 8X10 Cartridge Holder - WAT082887
SKU: WAT082887
RCM 8X10 Cartridge Holder - WAT082887
List Price
$431.00
Category: Service Parts & Kits
Buy RCM 8X10 Cartridge Holder - WAT082887 from Waters
Part Number: WAT082887
XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005270
SKU: 186005270
XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005270
List Price
$930.00
Category: Columns
XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186005270: XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.
Part Number: 186005270
Brand: XSelect
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology CSH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554
SKU: 186002554
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554
List Price
$790.00
Category: Columns
SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002554: SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.
Part Number: 186002554
Brand: SunFire
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
Oasis MCX 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm, 100/pk - 186000254
SKU: 186000254
Oasis MCX 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm, 100/pk - 186000254
List Price
$309.00
Category: Sample Preparation & Filtration
Oasis MCX 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm, 100/pk - 186000254: The 3 cc Oasis MCX cartridges contain the Oasis MCX, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. Since the Oasis MCX sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.
Part Number: 186000254
Brand: Oasis
Barrel Size 3 cc
Chemistry MCX
Endcapped No
Format Vac Cartridge
Ion Exchange Capacity 1 meq/gram
Mass Spec Compatibility Yes
Material Polypropylene
Mode Mixed mode
Particle Size 30 µm
Pore Size 80 Å
Sorbent Substrate Copolymer
Sorbent Weight 60 mg
Units per Package 100 pk
Water Wettable Yes
pH Range Max 14 pH
pH Range Min 0 pH
Oasis MAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm, 1/pk - 186001829
SKU: 186001829
Oasis MAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm, 1/pk - 186001829
List Price
$345.00
Category: Sample Preparation & Filtration
Oasis MAX 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm, 1/pk - 186001829: The patented 96-well Oasis MAX µElution plate is designed for SPE cleanup and analyte enrichment of sample volumes ranging from 10 µL to 375 µL. Each well of the µElution plate contains 2 mg of the Oasis MAX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting acidic compounds with anion-exchange groups. The innovative features of Oasis µElution plate enabled elution in only 25 µL, resulting in sensitive, robust, reproducible results without evaporation and reconstitution. A 15-fold sample enrichment is possible with this plate. The Oasis MAX µElution plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.
Part Number: 186001829
Brand: Oasis
Chemistry MAX
Endcapped No
Format 96-well µElution Plate
Ion Exchange Capacity 0.2 meq/gram
Mass Spec Compatibility Yes
Material Polypropylene
Mode Mixed mode
Number of Wells 96
Particle Size 30 µm
Pore Size 80 Å
Product Type Solid Phase Extraction
Sorbent Substrate Copolymer
Sorbent Weight 2 mg
Units per Package 1 pk
Water Wettable Yes
pH Range Max 14 pH
pH Range Min 0 pH
Sep-Pak Alumina N Plus Long Cartridge, 1710 mg Sorbent per Cartridge, 50 - 300 µm, 50/pk - WAT020510
SKU: WAT020510
Sep-Pak Alumina N Plus Long Cartridge, 1710 mg Sorbent per Cartridge, 50 - 300 µm, 50/pk - WAT020510
List Price
$206.00
Category: Sample Preparation & Filtration
Sep-Pak Alumina N Plus Long Cartridge, 1710 mg Sorbent per Cartridge, 50 - 300 µm, 50/pk - WAT020510: Sep-Pak Alumina N Plus Long cartridges contain a highly active grade of alumina with a neutral surface chemistry. The aluminum oxide surface provides an extremely polar surface for analyte retention and has properties of a Lewis acid. This normal phase sorbent is similar in use to silica; however, it is slightly more stable than unfunctionalized silica under high pH conditions. This neutral alumina is suitable for applications such as synthetic crude oil fractionation. These versatile Plus Long cartridges can attach easily to pumps and syringes for reliable, positive-pressure flow to speed up the sample processing time. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.
Part Number: WAT020510
Brand: Sep-Pak
Chemistry Alumina N
Format Plus Long Cartridge
Hold up volume 1.2 mL
Mass Spec Compatibility Yes
Mode Normal-phase
Particle Size 50-300 µm
Pore Size 120 Å
Sorbent Substrate Alumina
Sorbent Weight 1710 mg
Units per Package 50 pk
Water Wettable Yes
pH Range Max 10 pH
pH Range Min 0 pH
SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002732
SKU: 186002732
SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002732
List Price
$790.00
Category: Columns
SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186002732: SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.
Part Number: 186002732
Brand: SunFire
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Silica
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 8 pH
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186003613
SKU: 186003613
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186003613
List Price
$975.00
Category: Columns
XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186003613: The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
Part Number: 186003613
Brand: XBridge
Application Peptide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004021
SKU: 186004021
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004021
List Price
$3915.00
Category: Columns
XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pk - 186004021: As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Part Number: 186004021
Brand: XBridge
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
Inner Diameter 19 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Preparative Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 80 C (Low pH)/60 C (High pH)
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
UV Wavelength Accuracy (erbium perchlorate) - WAT042885
SKU: WAT042885
UV Wavelength Accuracy (erbium perchlorate) - WAT042885
List Price
$82.00
Category: Standards & Reagents
UV Wavelength Accuracy (erbium perchlorate) - WAT042885: Kit contains standards appropriate for assessment of UV Detector. 1X10mL standard solution contains: 10.0 gm/L Erbuim Perchlorate +/-5%) (Purity >=99.9%) in 100% HPLC Grade Water
Part Number: WAT042885
Application System Calibration, System Performance
Detection Method UV
Formulation Liquid
Product Type Standards
Quantitative Yes
Separation Mode Reversed Phase
Shelf Life 36 Months
Shipping Ambient
Storage Room Temperature
System Type LC
Tolarence 0.05
Type Calibration
Units per Package 1 pk
Volume 10 mL
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186003045
SKU: 186003045
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186003045
List Price
$930.00
Category: Columns
XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pk - 186003045: XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Part Number: 186003045
Brand: XBridge
Bonding Technology Shield RP18
Carbon Load 17 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 11 pH
GlycoWorks HILIC µElution Plate - 186002780
SKU: 186002780
GlycoWorks HILIC µElution Plate - 186002780
List Price
$1155.00
Category: Sample Preparation & Filtration
GlycoWorks HILIC µElution Plate - 186002780: This plate is ideal for removing contaminants like salts and detergents from hydrophilic analytes, such as carbohydrates, prior to mass spectrometry analysis. It enables elution volumes as low as 25 µL, thereby eliminating time-consuming evaporation steps. The eluted carbohydrates can be analyzed directly by MALDI MS without any prior derivatization. This plate can be used alone for the purpose of extracting carbohydrates, or it can be used as part of our glycan analysis kit (Waters MassPREP Glycoanalysis Kit) to clean up the glycans released from glycoproteins after deglycosylation.
Part Number: 186002780
Brand: GlycoWorks
Application Released n-glycan Analysis
Product Type Solid Phase Extraction
Units per Package 1 pk
LCMS Certified Clear Glass 12 x 32 mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk - 600000671CV
SKU: 600000671CV
LCMS Certified Clear Glass 12 x 32 mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk - 600000671CV
List Price
$199.00
Category: Vials, Containers, & Collection Plates
LCMS Certified Clear Glass 12 x 32 mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk - 600000671CV: All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.
Part Number: 600000671CV
Application Sample Preparation
Cap Color Blue
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32 mm
Format Total Recovery Vial
Includes Vial, Cap, & Septum
Material Clear Glass
Product Type Vials
Seal Material preslit PTFE/Silicone
Type Autosampler vial
Units per Package 100 pk
Vials Sample Limited Sample Limited
Volume Capacity 1 mL
XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186000490
SKU: 186000490
XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186000490
List Price
$880.00
Category: Columns
XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pk - 186000490: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000490
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT085721
SKU: WAT085721
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT085721
List Price
$470.00
Category: Columns
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk - WAT085721: µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.
Part Number: WAT085721
Brand: µBondapak
Carbon Load 10 %
Chemistry C18
Endcapped Yes
Format Radial-Pak Column
Inner Diameter 8 mm
Length 100 mm
Maximum Pressure 1500 psi (100 Bar)
Particle Shape Irregular
Particle Size 10 µm
Particle Substrate Silica
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity High
Surface Area 330
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 45
USP Classification L1
Units per Package 1 pk
pH Range 8 pH
LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, Max Recovery, with Cap and Preslit PTFE/Silicone Septum, 1.5 mL Volume, 100/pk - 186000327C
SKU: 186000327C
LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, Max Recovery, with Cap and Preslit PTFE/Silicone Septum, 1.5 mL Volume, 100/pk - 186000327C
List Price
$169.00
Category: Vials, Containers, & Collection Plates
LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, Max Recovery, with Cap and Preslit PTFE/Silicone Septum, 1.5 mL Volume, 100/pk - 186000327C: Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.
Part Number: 186000327C
Application Sample Preparation
Cap Color Blue
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32 mm
Format Max Recovery Vial
Includes Vial, Cap, & Septum
Material Clear Glass
Product Type Vials
Seal Material PTFE/Silicone
Type Autosampler vial
Units per Package 100 pk
Vials Sample Limited Sample Limited
Volume Capacity 1.5 mL
ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 3/pk - 176001132
SKU: 176001132
ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 3/pk - 176001132
List Price
$2535.00
Category: Columns
ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 3/pk - 176001132: The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations.
Part Number: 176001132
Brand: ACQUITY UPLC
Bonding Technology T3
Carbon Load 11 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.8 µm
Particle Substrate Silica
Particle Technology HSS
Pore Size 100 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 230
System UHPLC, UPLC
Temperature Limits 45
USP Classification L1
Units per Package 3 pk
eCord Yes
pH Range 8 pH
Oasis HLB 96-well Plate, 10 mg Sorbent per Well, 30 µm, 1/pk - 186000128
SKU: 186000128
Oasis HLB 96-well Plate, 10 mg Sorbent per Well, 30 µm, 1/pk - 186000128
List Price
$361.00
Category: Sample Preparation & Filtration
Oasis HLB 96-well Plate, 10 mg Sorbent per Well, 30 µm, 1/pk - 186000128: The Oasis HLB 96-well plate contains the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. The unique balance of hydrophobicity and water-wettability of the Oasis HLB sorbent means you will never have to worry about poor results if individual wells of the 96-well plate dry out during the critical steps prior to sample loading. The Oasis HLB 96-well plate is designed to be used on many manifold configurations and most robotic liquid handling systems.
Part Number: 186000128
Brand: Oasis
Chemistry HLB
Endcapped No
Format 96-well Plate
Mass Spec Compatibility Yes
Material Polypropylene
Mode Reversed-phase
Number of Wells 96
Particle Size 30 µm
Pore Size 80 Å
Product Type Solid Phase Extraction
Sorbent Substrate Copolymer
Sorbent Weight 10 mg
Units per Package 1 pk
Water Wettable Yes
pH Range Max 14 pH
pH Range Min 0 pH
ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186003556
SKU: 186003556
ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186003556
List Price
$1035.00
Category: Columns
ACQUITY UPLC Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk - 186003556: The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.
Part Number: 186003556
Brand: ACQUITY UPLC
Application Peptide
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Molecular Weight Range Max 15000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
QC Tested Peptide
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
AccQ-Tag Ultra Derivatization Kit - 186003836
SKU: 186003836
AccQ-Tag Ultra Derivatization Kit - 186003836
List Price
$700.00
Category: Application Kits
AccQ-Tag Ultra Derivatization Kit - 186003836: Amino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Derivitization Kit is a component of the UPLC® Amino Acid Analysis Application Solution. This kit is executed with UV detection and is enough for 250 anaylses.
Part Number: 186003836
Brand: AccQ-Tag
Application Amino Acid Analysis
Product Type Application Kits
ACQUITY UPLC Protein BEH C4 Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004496
SKU: 186004496
ACQUITY UPLC Protein BEH C4 Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004496
List Price
$985.00
Category: Columns
ACQUITY UPLC Protein BEH C4 Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk - 186004496: Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity.
Part Number: 186004496
Brand: ACQUITY UPLC
Application Protein
Carbon Load 8 %
Chemistry C4
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Molecular Weight Range Max 30000
Molecular Weight Range Min 1000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 300 Å
Product Type Columns
QC Tested Protein
Separation Mode Reversed-Phase
Silanol Activity Low
System UHPLC, UPLC
USP Classification L26
Units per Package 1 pk
pH Range 12 pH
PIC Reagent B6 - WAT085140
SKU: WAT085140
PIC Reagent B6 - WAT085140
List Price
$198.00
Category: Standards & Reagents
PIC Reagent B6 - WAT085140: Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B6 is a 5 vials/pkg workable solution in UV range in mobile phase of 240+ nm.
Part Number: WAT085140
Detection Method UV
Formulation Liquid
Product Type Reagents
Separation Mode Reversed Phase
Shipping Ambient
Storage Room Temperature
System Type LC
Type Reagent
Units per Package 5 pk
Volume 15 mL
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186002884
SKU: 186002884
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186002884
List Price
$920.00
Category: Columns
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186002884: ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.
Part Number: 186002884
Brand: ACQUITY UPLC
Bonding Technology Phenyl-Hexyl
Carbon Load 15 %
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System UHPLC, UPLC
USP Classification L11
Units per Package 1 pk
eCord Yes
pH Range 12 pH
XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pk - 186000496
SKU: 186000496
XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pk - 186000496
List Price
$960.00
Category: Columns
XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pk - 186000496: XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000496
Brand: XTerra
Bonding Technology Shield RP18
Carbon Load 15 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 250 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 4.6 mm X 300 mm, 10K - 500K, 1/pk - 186005226
SKU: 186005226
ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 4.6 mm X 300 mm, 10K - 500K, 1/pk - 186005226
List Price
$3560.00
Category: Columns
ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 4.6 mm X 300 mm, 10K - 500K, 1/pk - 186005226: Based upon the highly successful BEH particle technology, the new patent pending ACQUITY UPLC BEH200 SEC column represents the first commer­cially available sub 2 ìm SEC chemistry. Fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 10,000 to 450,000 Daltons, the total system solution will routinely deliver fast, accurate aggregate determinations up to 10 times quicker that traditional HPLC-based SEC methods.
Part Number: 186005226
Brand: ACQUITY UPLC
Application Protein
Bonding Technology SEC
Carbon Load 12 %
Chemistry SEC
Endcapped No
Endfitting Type Parker-style
Format Column
Inner Diameter 4.6 mm
Length 300 mm
Molecular Weight Range Max 500000
Molecular Weight Range Min 10000
Particle Shape Spherical
Particle Size 1.7 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 200 Å
Product Type Columns
QC Tested Protein
Separation Mode SEC
Silanol Activity Low
Surface Area 220
System UHPLC, UPLC
USP Classification L33
Units per Package 1 pk
pH Range 8 pH
Low Volume 6 x 29 mm Insert, 300 µL Volume, with Plastic Spring 100/pk - WAT094170
SKU: WAT094170
Low Volume 6 x 29 mm Insert, 300 µL Volume, with Plastic Spring 100/pk - WAT094170
List Price
$107.00
Category: Vials, Containers, & Collection Plates
Low Volume 6 x 29 mm Insert, 300 µL Volume, with Plastic Spring 100/pk - WAT094170: Vial inserts are a solution in applications where there is limited sample volume. Choose the appropriate volume insert for your sample volume and vial size.
Part Number: WAT094170
Application Sample Preparation
Includes Insert
Product Type Inserts
Units per Package 100 pk
Vials Sample Limited Sample Limited
Volume Capacity 300 µL
XBridge BEH C18 Sentry Guard Cartridge, 130Å, 5 µm, 4.6 mm X 20 mm, 2/pk - 186003064
SKU: 186003064
XBridge BEH C18 Sentry Guard Cartridge, 130Å, 5 µm, 4.6 mm X 20 mm, 2/pk - 186003064
List Price
$340.00
Category: Columns
XBridge BEH C18 Sentry Guard Cartridge, 130Å, 5 µm, 4.6 mm X 20 mm, 2/pk - 186003064: As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.
Part Number: 186003064
Brand: XBridge
Carbon Load 18 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 4.6 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Particle Technology BEH
Pore Size 130 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 185
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
AcrodiscGHP,13mm 0.2µm w/minispike, 100/pk - WAT097962
SKU: WAT097962
AcrodiscGHP,13mm 0.2µm w/minispike, 100/pk - WAT097962
List Price
$268.00
Category: Sample Preparation & Filtration
AcrodiscGHP,13mm 0.2µm w/minispike, 100/pk - WAT097962: GHP has the broadest chemical compatibility and exhibits minimal protein binding
Part Number: WAT097962
Brand: Acrodisc
Diameter 13 mm
Filter Type GHP
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Material Polypropylene
Pore Size 0.2 µm
Product Type Filtration
Sample Volume < 10 mL
Separation Mode Aqueous
Units per Package 100 pk
LCGC Certified Amber Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk - 186000847C
SKU: 186000847C
LCGC Certified Amber Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk - 186000847C
List Price
$66.00
Category: Vials, Containers, & Collection Plates
LCGC Certified Amber Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk - 186000847C: Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.
Part Number: 186000847C
Application Sample Preparation
Cap Color Blue
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32 mm
Includes Vial, Cap, & Septum
Material Amber Glass
Product Type Vials
Seal Material preslit PTFE/Silicone
Type Autosampler vial
Units per Package 100 pk
Volume Capacity 2 mL
Sep-Pak C18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 55 - 105 µm, 30/pk - WAT043395
SKU: WAT043395
Sep-Pak C18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 55 - 105 µm, 30/pk - WAT043395
List Price
$124.00
Category: Sample Preparation & Filtration
Sep-Pak C18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 55 - 105 µm, 30/pk - WAT043395: Silica-based octadecyl bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages.
Part Number: WAT043395
Brand: Sep-Pak
Barrel Size 6 cc
Chemistry C18
Endcapped Yes
Format Vac Cartridge
Hold up volume 1.2 mL
Mass Spec Compatibility Yes
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125 Å
Sorbent Substrate Silica
Sorbent Weight 500 mg
Units per Package 30 pk
Water Wettable No
pH Range Max 8 pH
pH Range Min 2 pH