Product Listing:  XTerra MS C8 Column, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pk - 186000427 to XTerra MS C18 Prep Guard Cartridge, 125Å, 10 µm, 7.8 mm X 10 mm, 1/pk - 186001172

XTerra MS C8 Column, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pk - 186000427
SKU: 186000427
XTerra MS C8 Column, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pk - 186000427
List Price
$855.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 3.9 mm X 100 mm, 1/pk - 186000427: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000427
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3.9 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pk - 186000415
SKU: 186000415
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pk - 186000415
List Price
$660.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pk - 186000415: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000415
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 30 mm, 1/pk - 186000413
SKU: 186000413
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 30 mm, 1/pk - 186000413
List Price
$635.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 30 mm, 1/pk - 186000413: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000413
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3 mm
Length 30 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pk - 186000423
SKU: 186000423
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pk - 186000423
List Price
$945.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pk - 186000423: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000423
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 100 mm, 1/pk - 186000419
SKU: 186000419
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 100 mm, 1/pk - 186000419
List Price
$855.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 3 mm X 100 mm, 1/pk - 186000419: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000419
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 3 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 186000401
SKU: 186000401
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 186000401
List Price
$660.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pk - 186000401: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000401
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 30 mm, 1/pk - 186000399
SKU: 186000399
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 30 mm, 1/pk - 186000399
List Price
$635.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 30 mm, 1/pk - 186000399: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000399
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 30 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk - 186000409
SKU: 186000409
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk - 186000409
List Price
$945.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 150 mm, 1/pk - 186000409: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000409
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 150 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 186000405
SKU: 186000405
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 186000405
List Price
$855.00
Category: Columns
XTerra MS C8 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk - 186000405: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000405
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 2.1 mm
Length 100 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C8 Column, 125Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk - 186000603
SKU: 186000603
XTerra MS C8 Column, 125Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk - 186000603
List Price
$815.00
Category: Columns
XTerra MS C8 Column, 125Å, 2.5 µm, 4.6 mm X 50 mm, 1/pk - 186000603: XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000603
Brand: XTerra
Bonding Technology MS C8
Carbon Load 12 %
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
Inner Diameter 4.6 mm
Length 50 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Columns
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units per Package 1 pk
pH Range 12 pH
XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk - 186007899
SKU: 186007899
XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk - 186007899
List Price
$430.00
Category: Columns
XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk - 186007899: XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. XTerra MS C18 analytical columns containing 5 µm sorbent particles.
Part Number: 186007899
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 3.9 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 2.1 mm X 5 mm, 3/pk - 186007896
SKU: 186007896
XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 2.1 mm X 5 mm, 3/pk - 186007896
List Price
$430.00
Category: Columns
XTerra MS C18 VanGuard Cartridge, 125Å, 5 µm, 2.1 mm X 5 mm, 3/pk - 186007896: XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns containing 5 µm sorbent particles.
Part Number: 186007896
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk - 186007894
SKU: 186007894
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk - 186007894
List Price
$430.00
Category: Columns
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 3.9 mm X 5 mm, 3/pk - 186007894: XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. XTerra MS C18 analytical columns containing 3.5 µm sorbent particles.
Part Number: 186007894
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 3.9 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk - 186007892
SKU: 186007892
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk - 186007892
List Price
$430.00
Category: Columns
XTerra MS C18 VanGuard Cartridge, 125Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk - 186007892: XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns containing 3.5 µm sorbent particles.
Part Number: 186007892
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk - 186007889
SKU: 186007889
XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk - 186007889
List Price
$430.00
Category: Columns
XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 3.9 mm X 5 mm, 3/pk - 186007889: XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 3.9 mm and 4.6 mm I.D. XTerra MS C18 analytical columns containing 2.5 µm sorbent particles.
Part Number: 186007889
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 3.9 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk - 186007887
SKU: 186007887
XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk - 186007887
List Price
$430.00
Category: Columns
XTerra MS C18 VanGuard Cartridge, 125Å, 2.5 µm, 2.1 mm X 5 mm, 3/pk - 186007887: XTerra MS C18 VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XTerra MS C18 analytical columns containing 2.5 µm sorbent particles.
Part Number: 186007887
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Cartridge
Inner Diameter 2.1 mm
Length 5 mm
Maximum Pressure 18000 psi (1240 Bar)
Particle Shape Spherical
Particle Size 2.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 3.9 mm X 20 mm, 2/pk - 186000660
SKU: 186000660
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 3.9 mm X 20 mm, 2/pk - 186000660
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 3.9 mm X 20 mm, 2/pk - 186000660: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000660
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 3.9 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 3 mm X 20 mm, 2/pk - 186000656
SKU: 186000656
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 3 mm X 20 mm, 2/pk - 186000656
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 3 mm X 20 mm, 2/pk - 186000656: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000656
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 3 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 2.1 mm X 20 mm, 2/pk - 186000652
SKU: 186000652
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 2.1 mm X 20 mm, 2/pk - 186000652
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 2.1 mm X 20 mm, 2/pk - 186000652: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000652
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 2.1 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 2.1 mm X 10 mm, 2/pk - 186000648
SKU: 186000648
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 2.1 mm X 10 mm, 2/pk - 186000648
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 5 µm, 2.1 mm X 10 mm, 2/pk - 186000648: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000648
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 2.1 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 4.6 mm X 10 mm, 3/pk - 186001927
SKU: 186001927
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 4.6 mm X 10 mm, 3/pk - 186001927
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 4.6 mm X 10 mm, 3/pk - 186001927: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186001927
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 4.6 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 3 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3.9 mm X 20 mm, 2/pk - 186000644
SKU: 186000644
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3.9 mm X 20 mm, 2/pk - 186000644
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3.9 mm X 20 mm, 2/pk - 186000644: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000644
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 3.9 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3 mm X 20 mm, 2/pk - 186000640
SKU: 186000640
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3 mm X 20 mm, 2/pk - 186000640
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 3 mm X 20 mm, 2/pk - 186000640: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000640
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 3 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 20 mm, 2/pk - 186000636
SKU: 186000636
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 20 mm, 2/pk - 186000636
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 20 mm, 2/pk - 186000636: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000636
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 2.1 mm
Length 20 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pk - 186000632
SKU: 186000632
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pk - 186000632
List Price
$340.00
Category: Columns
XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pk - 186000632: XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.
Part Number: 186000632
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
Inner Diameter 2.1 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 3.5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units per Package 2 pk
pH Range 12 pH
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 7.8 mm X 10 mm, 1/pk - 186001168
SKU: 186001168
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 7.8 mm X 10 mm, 1/pk - 186001168
List Price
$245.00
Category: Columns
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 7.8 mm X 10 mm, 1/pk - 186001168: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001168
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
Inner Diameter 7.8 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pk - 186006903
SKU: 186006903
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pk - 186006903
List Price
$500.00
Category: Columns
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 30 mm X 10 mm, 1/pk - 186006903: 30x10mm Prep Guard Cartridge together with the 30x10mm Prep Guard Holder (part number 186006912) is designed to protect both HPLC and SFC 30 mm ID Prep OBD™ columns. Placing this guard assembly ahead of the prep column will provide longer column lifetimes and reduce purification costs.
Part Number: 186006903
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
Inner Diameter 30 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 19 mm X 10 mm, 1/pk - 186001104
SKU: 186001104
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 19 mm X 10 mm, 1/pk - 186001104
List Price
$425.00
Category: Columns
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 19 mm X 10 mm, 1/pk - 186001104: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001104
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
Inner Diameter 19 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 10 mm X 10 mm, 1/pk - 186001001
SKU: 186001001
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 10 mm X 10 mm, 1/pk - 186001001
List Price
$250.00
Category: Columns
XTerra MS C18 Prep Guard Cartridge, 125Å, 5 µm, 10 mm X 10 mm, 1/pk - 186001001: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001001
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
Inner Diameter 10 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 5 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
XTerra MS C18 Prep Guard Cartridge, 125Å, 10 µm, 7.8 mm X 10 mm, 1/pk - 186001172
SKU: 186001172
XTerra MS C18 Prep Guard Cartridge, 125Å, 10 µm, 7.8 mm X 10 mm, 1/pk - 186001172
List Price
$245.00
Category: Columns
XTerra MS C18 Prep Guard Cartridge, 125Å, 10 µm, 7.8 mm X 10 mm, 1/pk - 186001172: XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.
Part Number: 186001172
Brand: XTerra
Bonding Technology MS C18
Carbon Load 16 %
Chemistry C18
Endcapped Yes
Format Prep Guard Cartridge
Inner Diameter 7.8 mm
Length 10 mm
Maximum Pressure 6000 psi (415 Bar)
Particle Shape Spherical
Particle Size 10 µm
Particle Substrate Hybrid
Pore Size 125 Å
Product Type Guards
Separation Mode Reversed-Phase
Silanol Activity Low
Surface Area 175
System HPLC Preparative
Technique LC, LC/MS
Temperature Limits 60
USP Classification L1
Units per Package 1 pk
pH Range 12 pH
Back To Top