BioAnalysis Method Builder for an Oasis HLB Generic Method       
To find the right Oasis HLB SPE Product for your method      
1) Select type of compound you want to isolate?
 
2) Select preferred SPE format?
 
3) Select use of µElution format to eliminate the evaporation step* (Y/N)
 
4) Select your usual plasma load volumes range (min-max)  ?
 
         
To calculate the optimized Method Development Protocol for your method        
5) Input the plasma load volume you expect to use for this new method (µL)    
6) Input the mid-point of the concentration range for this new method (ng/mL)?    
7) Select the number of Data points (replicates) used for your Recovery Calculations
 
           
  SPE Product Details  
Oasis Color.jpg
 
Compound Type      
  Oasis SPE format  
  Format details  
  Waters Part Number to Order    
  © Copyright Waters Corporation 2014    
           
  SPE Method Calculated for selected SPE product      
  Plasma (sample) volume         
Oasis Bitmap.bmp
 
Pre-SPE Treatment (diluent) volume      
  Condition      
  Equilibrate      
  Load    
  Wash  
  Elute    
  Total Elution volume      
  SPE Concentration or Dilution Factor      
  Flow Rate for SPE method      
         
* It is recommended to avoid the evaporation step for volatile and/or heat labile Compounds      
*The µElution format allows sample concentration up to 15x without evaporation (when all the compound elutes in the first 25 µL)    
OASIS HLB Recovery and Matrix Effects Experimental Set-up  
Mid-point of the concentration range for this method ng/mL  
Number of Data points (replicates) required  
STANDARDS PREPARATION    
Concentrated Standard Stock Solution preparation (S1)    
   
   
Standard Solution preparation (S2)      
     
   
   
   
   
 Pre-Treatment (diluent) Preparation       
   
   
   
  © Copyright Waters Corporation 2014  
PLASMA PREPARATION  
Estimated total volume of bulk Plasma needed    
Pre-Spike Plasma preparation (P1)    
   
   
   
       
   
       
   
   
Post-Spike Plasma preparation (P2)    
   
   
   
       
   
       
   
             
OASIS HLB Calculating Recovery and Matrix Effects  
   
 
  Pre-SPE Spiked Samples   Post-SPE Spiked Samples   Standard Solution (Diluted S2)  
                   
  Load Pre-Spike Plasma (P1)   Load Post-Spike Plasma (P2)   Standard (S2) conc  (ng/mL)  
  Apply SPE Process     Apply SPE Process     Take Aliquot of    
  Elute   Elute   Standard Solution (S2)  
  Add Water   Add Standard Spike (S2)    
  Inject onto LC/MS   Inject onto LC/MS   Inject onto LC/MS  
  Final concentration (ng/mL)   Final concentration (ng/mL)   Final concentration (ng/mL)  
                   
  Enter Average LC/MS Area Counts   Enter Average LC/MS Area Counts   Enter Average LC/MS Area Counts  
       
         
         
    BioAnalysis Results    
       
  Recovery %      
  Matrix Effects %      
  Matrix Factor   © Copyright Waters Corporation 2014  
         
   
   
Oasis HLB Method Optimization
    Numbers shown are for example. Overwrite them with your experimental results  
    Acid Elution (% MeOH in Formic Acid)     Base Elution (% MeOH in Ammonium Hydroxide)
  0 10 20 30 40 50 60 70 80 90   0 10 20 30 40 50 60 70 80 90
  Analyte 1   Analyte 1
  Analyte 2   Analyte 2
  Analyte 3   Analyte 3
 
  % MeOH at lift-off for Acid Elutes (A1)   Enter values   % MeOH at lift-Off for Base Elutes (B1) Enter values  
  % MeOH at Area Count maxima (A2)   from graphs   % MeOH at Area Count maxima (B2)   from graphs  
 
 
 
 
Unable to load Flash content. The Charts Control requires Flash Player 9.0.45 or higher. You can download the latest version of Flash Player from the Adobe Flash Player Download Center
 
 
Unable to load Flash content. The Charts Control requires Flash Player 9.0.45 or higher. You can download the latest version of Flash Player from the Adobe Flash Player Download Center
 
 
     
     
     
     
     
     
     
     
     
     
     
     
  RESULT  
  Wash with  
       
  Elute with  
        © Copyright Waters Corporation 2014    
 
  Original HLB Method   Optimized HLB Method  
  Condition   Condition  
  Equilibrate   Equilibrate  
  Load     Load    
  Wash     Wash    
  Elute     Elute    
 
   