XTerra HPLC Columns

  Product    
info

186001180 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186001180

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001180 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186001180
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001179 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186001179

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001179 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186001179
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001178 - XTerra Phenyl Column, 125Å, 3.5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186001178

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001178 - XTerra Phenyl Column, 125Å, 3.5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186001178
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001181 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186001181

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001181 - XTerra Phenyl Column, 125Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186001181
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001141 - XTerra Phenyl Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186001141

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001141 - XTerra Phenyl Column, 125Å, 3.5 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186001141
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001146 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001146

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001146 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001146
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001145 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186001145

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001145 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186001145
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001144 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186001144

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001144 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186001144
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001147

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001147
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186000526 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000526

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000526 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000526
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000534 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000534

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000534 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000534
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000530 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000530

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000530 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000530
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000518 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186000518

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000518 - XTerra MS C18 Cartridge, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186000518
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000546 - XTerra MS C18 Cartridge, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186000546

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000546 - XTerra MS C18 Cartridge, 125Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186000546
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000570 - XTerra MS C18 Cartridge, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000570

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000570 - XTerra MS C18 Cartridge, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000570
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000554 - XTerra MS C18 Cartridge, 125Å, 5 µm, 3 mm X 50 mm, 1/pkg

Part Number: 186000554

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000554 - XTerra MS C18 Cartridge, 125Å, 5 µm, 3 mm X 50 mm, 1/pkg
Part Number: 186000554
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000578 - XTerra MS C18 Cartridge, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000578

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000578 - XTerra MS C18 Cartridge, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000578
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186000404

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186000404
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000398 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186000398

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000398 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186000398
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000436 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000436

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000436 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000436
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12