XBridge Shield RP18 Column

  Product    
info

186003149 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 1 mm X 100 mm, 1/pkg

Part Number: 186003149

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003149 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 1 mm X 100 mm, 1/pkg
Part Number: 186003149
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003003 - XBridge BEH Shield RP18 Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003003

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003003 - XBridge BEH Shield RP18 Column, 130Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003003
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003156 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 20 mm, 1/pkg

Part Number: 186003156

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003156 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 20 mm, 1/pkg
Part Number: 186003156
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003163 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186003163

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003163 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186003163
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003151 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 2.1 mm X 20 mm, 1/pkg

Part Number: 186003151

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003151 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 2.1 mm X 20 mm, 1/pkg
Part Number: 186003151
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003157 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186003157

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003157 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186003157
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003155 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186003155

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003155 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186003155
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186006774 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 3 mm X 150 mm, 3/pkg

Part Number: 186006774

This method validation kit consists of three XBridge BEH Shield RP18 columns packed with three different batches of sorbent. XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006774 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 3 mm X 150 mm, 3/pkg
Part Number: 186006774
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186003154 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003154

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003154 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003154
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186006210 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 186006210

This method validation kit consists of three batches of XBridge BEH Shield RP18 columns packed with three different batches of sorbent

186006210 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 186006210
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186003162 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003162

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003162 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003162
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003152 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 20 mm, 1/pkg

Part Number: 186003152

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003152 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 20 mm, 1/pkg
Part Number: 186003152
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003144 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 2.5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003144

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003144 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 2.5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003144
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003071 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 5 µm, 2.1 mm X 10 mm, 2/pkg

Part Number: 186003071

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003071 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 5 µm, 2.1 mm X 10 mm, 2/pkg
Part Number: 186003071
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 2.1 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 11

info

186003789 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 3.5 µm, 3 mm X 100 mm, 3/pkg

Part Number: 186003789

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003789 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 3.5 µm, 3 mm X 100 mm, 3/pkg
Part Number: 186003789
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186003997 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186003997

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003997 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186003997
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003793 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 5 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186003793

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003793 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 5 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186003793
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186004002 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg

Part Number: 186004002

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186004002 - XBridge BEH Shield RP18 OBD Prep Column, 130Å, 10 µm, 50 mm X 250 mm, 1/pkg
Part Number: 186004002
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 50 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186006775 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186006775

This method validation kit consists of three XBridge BEH Shield RP18 columns packed with three different batches of sorbent. XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006775 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 2.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186006775
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11

info

186003795 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 5 µm, 3 mm X 150 mm, 3/pkg

Part Number: 186003795

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003795 - XBridge BEH Shield RP18 Method Validation Kit, 130Å, 5 µm, 3 mm X 150 mm, 3/pkg
Part Number: 186003795
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 11