Viridis Csh Fluoro-Phenyl Column

  Product    
info

186006573 - Viridis CSH Fluoro-Phenyl Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186006573

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006573 - Viridis CSH Fluoro-Phenyl Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186006573
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186006569 - Viridis CSH Fluoro-Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006569

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006569 - Viridis CSH Fluoro-Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006569
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005708 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186005708

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005708 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186005708
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005706

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005706
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005705

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005705
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005704 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186005704

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005704 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186005704
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186006566 - Viridis CSH Fluoro-Phenyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006566

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006566 - Viridis CSH Fluoro-Phenyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006566
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Parker-style
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
System UPC2/SFC
Technology CSH
Units in Package 3/pkg

info

186006642 - Viridis CSH Fluoro-Phenyl VanGuard Pre-column, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006642

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006642 - Viridis CSH Fluoro-Phenyl VanGuard Pre-column, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006642
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Parker-style
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 3/pkg

info

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005709

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005709
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg