Phenyl Prep Column

  Product    
info

186005702 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186005702

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005702 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186005702
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005708 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186005708

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005708 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186005708
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005706

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005706 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005706
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005705

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005705 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005705
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005704 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186005704

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005704 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186005704
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg

Part Number: 186005709

Designed and tested for SFC, the Viridis 5 µm columns demonstrate a wide range of selectivity for greater resolution. The reduction and control of surface silanol activity on Viridis Hybrid particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186005709 - Viridis CSH Fluoro-Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 50 mm, 1/pkg
Part Number: 186005709
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > Technologies > OBD (Optimum Bed Density) Technology
% Carbon Load 10
Chemistry Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 50 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology CSH
Units in Package 1/pkg

info

186005500 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186005500

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005500 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186005500
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005437 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005437

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005437 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005437
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005438 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg

Part Number: 186005438

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005438 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 100 mm, 1/pkg
Part Number: 186005438
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005439 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186005439

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005439 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186005439
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005436 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186005436

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005436 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186005436
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005435 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186005435

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005435 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186005435
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005499 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186005499

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005499 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186005499
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005433 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg

Part Number: 186005433

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005433 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm, 1/pkg
Part Number: 186005433
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005434 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg

Part Number: 186005434

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005434 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg
Part Number: 186005434
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005503 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg

Part Number: 186005503

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005503 - XSelect CSH Fluoro Phenyl OBD Prep Column, 130Å, 5 µm, 50 mm X 150 mm, 1/pkg
Part Number: 186005503
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 50 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186005507 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg

Part Number: 186005507

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005507 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 250 mm, 1/pkg
Part Number: 186005507
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005447 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg

Part Number: 186005447

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005447 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 19 mm X 100 mm, 1/pkg
Part Number: 186005447
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005450 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg

Part Number: 186005450

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005450 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 30 mm X 75 mm, 1/pkg
Part Number: 186005450
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186005448 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186005448

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005448 - XSelect CSH Phenyl-Hexyl OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186005448
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11