Cation Exchange Column HPLC

  Product    
info

186002183 - BioSuite Cation-exchange Column, Non-porous, 2.5 µm, 4.6 mm X 35 mm, 1/pkg

Part Number: 186002183

Waters BioSuite™ ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002183 - BioSuite Cation-exchange Column, Non-porous, 2.5 µm, 4.6 mm X 35 mm, 1/pkg
Part Number: 186002183
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 35 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Polymer
Pore Size Non-porous
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

186002182 - BioSuite Cation-exchange Column, 1300Å, 7 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186002182

Waters BioSuite™ ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002182 - BioSuite Cation-exchange Column, 1300Å, 7 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186002182
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Polymer
Pore Size 1300Å
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

186002186 - BioSuite CM Cation-exchange Column, 1000Å, 10 µm, 7.5mm X 75 mm, 1/pkg

Part Number: 186002186

Waters BioSuite; ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002186 - BioSuite CM Cation-exchange Column, 1000Å, 10 µm, 7.5mm X 75 mm, 1/pkg
Part Number: 186002186
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 7.5mm
Length (mm) 75 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Polymer
Pore Size 1000Å
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

186002187 - BioSuite CM Cation-exchange Column, 1000Å, 13 µm, 21.5 mm X 150 mm, 1/pkg

Part Number: 186002187

Waters BioSuite; ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002187 - BioSuite CM Cation-exchange Column, 1000Å, 13 µm, 21.5 mm X 150 mm, 1/pkg
Part Number: 186002187
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 21.5 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 13 µm
Particle Substrate Polymer
Pore Size 1000Å
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

186002184 - BioSuite SP Cation-exchange Column, 1000Å, 10 µm, 7.5mm X 75 mm, 1/pkg

Part Number: 186002184

Waters BioSuite; ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002184 - BioSuite SP Cation-exchange Column, 1000Å, 10 µm, 7.5mm X 75 mm, 1/pkg
Part Number: 186002184
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 7.5mm
Length (mm) 75 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Polymer
Pore Size 1000Å
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

186002185 - BioSuite SP Cation-exchange Column, 1000Å, 13 µm, 21.5 mm X 150 mm, 1/pkg

Part Number: 186002185

Waters BioSuite; ion-exchange column offerings include strong and weak, cation (CXC) and anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin. The availability of four separation chemistries provides chromatographers with the flexibility required to develop methods that separate proteins and / or peptides based upon minor charge differences. Nonporous (NP) and porous IEX columns are also available. Superior chromatographic resolution is possible using the nonporous IEX offerings however, greater binding capacity is obtained with the porous selections. In addition, selected BioSuite™ ion-exchange columns are available in PEEK hardware as well as in 21.5 mm preparative column sizes.

186002185 - BioSuite SP Cation-exchange Column, 1000Å, 13 µm, 21.5 mm X 150 mm, 1/pkg
Part Number: 186002185
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Protein
Chemistry Cation-exchange
Endfitting Type Parker-style
Format Column
ID 21.5 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 13 µm
Particle Substrate Polymer
Pore Size 1000Å
System HPLC
Units in Package 1/pkg
pH Range 2 - 12

info

WAT007356 - IC-Pak Cation Guard Column, 10 µm, 4.6 x 50 mm

Part Number: WAT007356

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT007356 - IC-Pak Cation Guard Column, 10 µm, 4.6 x 50 mm
Part Number: WAT007356
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Guard Column
ID 4.6 mm
Length (mm) 50 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

WAT007354 - IC-Pak Cation Column, 10 µm, 4.6 x 50 mm

Part Number: WAT007354

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT007354 - IC-Pak Cation Column, 10 µm, 4.6 x 50 mm
Part Number: WAT007354
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

186003301 - IC-Pak Cation M/D Column, 2.1 x 150 mm

Part Number: 186003301

The silica-based IC-Pak C M/D column allows a simultaneous analysis of monovalent and divalent cations under isocratic conditions. This technology provides the analytical chemist with the most sensitive means of analyzing monovalent cations such as Na+, K+, Li+ and NH4+.

186003301 - IC-Pak Cation M/D Column, 2.1 x 150 mm
Part Number: 186003301
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

WAT044250 - IC-Pak Cation M/D Guard Pak Inserts, 10/pk

Part Number: WAT044250

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT044250 - IC-Pak Cation M/D Guard Pak Inserts, 10/pk
Part Number: WAT044250
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Guard-Pak Insert
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 10/pkg

info

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm

Part Number: WAT036570

The silica-based IC-Pak C M/D column allows a simultaneous analysis of monovalent and divalent cations under isocratic conditions. This technology provides the analytical chemist with the most sensitive means of analyzing monovalent cations such as Na+, K+, Li+ and NH4+.

WAT036570 - IC-Pak Cation M/D Column, 3.9 x 150 mm
Part Number: WAT036570
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 5 µm
Units in Package 1/pkg