Calibration Kits

  Product    
info

186007539 - ACQUITY APC Polystyrene Low MW Calibration Kit

Part Number: 186007539

APC™ Calibration Standards were specifically designed to match the molecular weight range of the ACQUITY APC™ XT Columns. They eliminate the need to manually prepare custom standard calibration mixes as ACQUITY APC Calibration Standards provide the right number of data points for the targeted MW range. Contains: -Ten clear vials with green cap; containing 1.5 mg each of polystyrene at Mp 15.7K, 4.92K, 1.25K -Ten clear vials with dark blue cap containing 1.5 mg each of polystyrene at Mp 9.13K, 3.47K, 0.474K -Ten clear vials with black cap containing 1.5 mg each of polystyrene at Mp 6.54K, 2.28K, 0.266K

186007539 - ACQUITY APC Polystyrene Low MW Calibration Kit
Part Number: 186007539
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Packaging Kit
Product Type Kit
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C

info

186007546 - ACQUITY APC Polymethylmethacrylate Method Development MW Calibration Kit

Part Number: 186007546

APC™ Calibration Standards were specifically designed to match the molecular weight range of the ACQUITY APC™ XT Columns. They eliminate the need to manually prepare custom standard calibration mixes as ACQUITY APC Calibration Standards provide the right number of data points for the targeted MW range. Contains: -Three amber vials with yellow cap containing 0.75 mg each of PMMA at Mp 1600K, and 1.5mg PMMA at Mp 201K, 23.5K, 2.38K -Three amber vials with purple cap containing 1.5 mg each of PMMA at Mp 608K, 88.5K, 12.6K, 0.602K -Three amber vials with pink cap containing 1.5 mg each of PMMA at Mp 340K, 41.4K, 6.37K, 0.202K -Three amber vials with light blue cap containing 1.5 mg each of PMMA Mp 108K, 23.5K, 4.23K, 0.602K -Three amber vials with red caps containing 1.5 mg each of PMMA at Mp 201K, 41.4K, 6.37K, 1.102K -Three amber vials with white cap containing 1.5 mg each of PMMA at Mp 71.8K, 12.6K, 2.38K, 0.202K -Three amber vials with green cap; containing 1.5 mg each of PMMA at Mp 12.6K, 4.23K, 1.102K -Three amber vials with dark blue cap containing 1.5 mg each of PMMA at Mp 9.68K, 3.21K, 0.602K -Three amber vials with black cap containing 1.5 mg each of PMMA at Mp 6.37K, 2.38K, 0.202K -Three vials with 1.5 mg BHT

186007546 - ACQUITY APC Polymethylmethacrylate Method Development MW Calibration Kit
Part Number: 186007546
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Chemical
Packaging Kit
Product Type Kit
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C

info

186008046 - IC Phosphate Calibration Kit 350–550mg/L

Part Number: 186008046

The IC Phosphate Calibration Kit (350-550 mg/L) consists of four individual reference standards (three calibration standards at 350, 450, 550 mg/L of phosphate and one check standard at 445 mg/L of phosphate in ultra pure deionized water), which are intended for use as calibration standards for ion chromatography to analyze phosphate/phosphoric acid levels in beverages. These standards are manufactured from potassium phosphate monohydrate and potassium sulfate. They are directly traceable to NIST Reference Standards and meet ISO Guide 31 on reference materials. A copy of the Certificate of Analysis will be included with each shipment. This kit contains the following: - 1 bottle of 350 mg/L Phosphate Calibration Standard, 125 mL - 1 bottle of 450 mg/L Phosphate Calibration Standard, 125 mL - 1 bottle of 550 mg/L Phosphate Calibration Standard, 125 mL - 1 bottle of 445 mg/L Phosphate Check Standard, 125 mL Each of the individual kit components can be purchased separately as a refill.

186008046 - IC Phosphate Calibration Kit 350–550mg/L
Part Number: 186008046
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Food
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp

info

186008113 - Major Mix IMS/Tof Calibration Kit

Part Number: 186008113

The Major Mix IMS/Tof Calibration Kit is intended to be used as a calibration solution for high resolution mass spectrometers equipped with ion mobility. This kit is also utilized in the on-board calibration of the VionTM IMS QTof system. The following items are included in the Major Mix IMS/Tof Calibration Kit: 2x ampoules each containing a 2 mL solution of the following in a 50:50 acetonitrile:water matrix. .01 mg/mL succinic acid 1 ng/µL salicylic acid 1 ng/µL theophylline 0.1 ng/µL pantothenic acid 2 ng/µL stearic acid 0.1 ng/µL perfluoroheptanoic acid 0.1 ng/µL perfluorooctanoic acid 0.1 ng/µL perfluorononanoic acid 0.1 ng/µL perfluorodecanoic acid 0.1 ng/µL perfluorododecanoic acid .03 mg/mL poly-DL-alanine .001% ultramark 1621 2x bottles each containing a 17 mL of the (49.95:49.95) acetonitrile:water + 0.1% formic acid. 2x LCMS QC Reference Standard (p/n 186006963) each containing a 500 μL mixture of the following components in a 5.7% acetonitrile/94.3% water + formic acid matrix. 10.0 μg/mL acetaminophen 1.5 μg/mL caffeine 5.0 μg/mL sulfaguanidine 1.0 μg/mL sulfadimethoxine 2.5 μg/mL Val,-Tyr-Val 0.2 μg/mL verapamil 0.2 μg/mL terfenadine 2.5 μg/mL leucine-enkephalin 0.6 μg/mL reserpine Store at -20°C ± 10ºC (frozen) upon arrival.

186008113 - Major Mix IMS/Tof Calibration Kit
Part Number: 186008113
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Frozen -20 C
System LC/MS

info

700002287 - Electrochemical Detector PQ Mobile Phase

Part Number: 700002287

This Mobile Phase is used when running the Electrochemical PQ procedure.

700002287 - Electrochemical Detector PQ Mobile Phase
Part Number: 700002287
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Qualification/Calibration Kits
Product Category Detectors
Products 2465 Electrochemical Detector
Replacement Schedule As Needed

info

700002310 - Conductivity Detector OQ/PQ Mobile Phase

Part Number: 700002310

This is the Mobile Phase used when running the Conductivity OQ/PQ procedure.

700002310 - Conductivity Detector OQ/PQ Mobile Phase
Part Number: 700002310
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Qualification/Calibration Kits
Product Category Detectors
Products 432 Conductivity Detector
Replacement Schedule As Needed

info

700002419 - Waters RI Qual. Mobile Phase (2L)

Part Number: 700002419

This mobile phase is used when running the RI OQ/PQ Qualification Workbook.

700002419 - Waters RI Qual. Mobile Phase (2L)
Part Number: 700002419
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Qualification/Calibration Kits
Product Category Detectors
Products 2410 Differential Refractive Index Detector
2414 Refractive Index Detector
410 Refractive Index Detector
Replacement Schedule As Needed