130Å XBridge BEH C18 Intelligent Speed (IS) Column

Also showing 130Å BEH C18 Intelligent Speed (IS) Column

  Product    
info

186003024 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 20 mm, 1/pkg

Part Number: 186003024

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003024 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 20 mm, 1/pkg
Part Number: 186003024
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003134 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003134

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003134 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003134
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003107 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 20 mm, 1/pkg

Part Number: 186003107

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003107 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 20 mm, 1/pkg
Part Number: 186003107
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003019 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 2.1 mm X 20 mm, 1/pkg

Part Number: 186003019

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003019 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 2.1 mm X 20 mm, 1/pkg
Part Number: 186003019
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003130 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 5 µm, 3 mm X 20 mm, 1/pkg

Part Number: 186003130

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003130 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 5 µm, 3 mm X 20 mm, 1/pkg
Part Number: 186003130
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003029 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003029

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003029 - XBridge BEH C18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003029
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003159 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186003159

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003159 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186003159
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003158 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 3 mm X 20 mm, 1/pkg

Part Number: 186003158

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003158 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 3 mm X 20 mm, 1/pkg
Part Number: 186003158
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003140 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 2.5 µm, 3 mm X 20 mm, 1/pkg

Part Number: 186003140

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003140 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 2.5 µm, 3 mm X 20 mm, 1/pkg
Part Number: 186003140
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003153 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186003153

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003153 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186003153
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003156 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 20 mm, 1/pkg

Part Number: 186003156

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003156 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 20 mm, 1/pkg
Part Number: 186003156
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003163 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186003163

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003163 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186003163
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003151 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 2.1 mm X 20 mm, 1/pkg

Part Number: 186003151

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003151 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 2.1 mm X 20 mm, 1/pkg
Part Number: 186003151
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003157 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186003157

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003157 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186003157
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003155 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186003155

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003155 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186003155
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003154 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003154

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003154 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003154
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003162 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003162

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003162 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003162
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003152 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 20 mm, 1/pkg

Part Number: 186003152

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003152 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 3.5 µm, 3 mm X 20 mm, 1/pkg
Part Number: 186003152
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003144 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 2.5 µm, 4.6 mm X 20 mm, 1/pkg

Part Number: 186003144

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003144 - XBridge BEH Shield RP18 Intelligent Speed (IS) Column, 130Å, 2.5 µm, 4.6 mm X 20 mm, 1/pkg
Part Number: 186003144
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Intelligent Speed (IS) Column
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11