130Å BEH HILIC VanGuard Pre-column

  Product    
info

186003980 - ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003980

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003980 - ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003980
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity High
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 9

info

186007262 - XBridge Glycan BEH Amide VanGuard Pre-column, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007262

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007262 - XBridge Glycan BEH Amide VanGuard Pre-column, 130Å, 2.5 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007262
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11

info

186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004739

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186004739
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11