Product Listing:  WAT044237 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, THF , 1/pkg   to   WAT054392 - Dextrans Standard

Sorted by Title
  Product    
info

WAT044237 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, THF , 1/pkg

Part Number: WAT044237

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044237 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, THF , 1/pkg
Part Number: WAT044237
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 20K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 2
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044250 - IC-Pak Cation M/D Guard Pak Inserts, 10/pk

Part Number: WAT044250

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT044250 - IC-Pak Cation M/D Guard Pak Inserts, 10/pk
Part Number: WAT044250
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Guard-Pak Insert
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 10/pkg

info

WAT044355 - Carbohydrate Cartridge Column, 4.6 x 250 mm

Part Number: WAT044355

Waters High-Performance Carbohydrate Cartridge Column is packed with 4-μm spherical silica. This column was developed to separate five monosaccharides and disaccharides to give baseline resolution in fewer than 12 minutes. The pre-packed, disposable cartridge column requires reusable end-fittings, which are available separately.

WAT044355 - Carbohydrate Cartridge Column, 4.6 x 250 mm
Part Number: WAT044355
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
USP Classification L8
Units in Package 1/pkg

info

WAT044375 - Nova-Pak C18 Column, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT044375

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT044375 - Nova-Pak C18 Column, 60Å, 4 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT044375
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT044380 - Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT044380

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT044380 - Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT044380
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Guard Column
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

WAT045905 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045905

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045905 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045905
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045995

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045995
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046-12 - Compression Screws, 1/8in., PEEK

Part Number: WAT046-12

The PEEK compression screws are an option to be used when stainless steel compression screws are not compatible.

WAT046-12 - Compression Screws, 1/8in., PEEK
Part Number: WAT046-12
Products > Chromatography Consumables & Columns > Accessories > Fittings
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

WAT046850 - µBondapak Phenyl Sentry Guard Cartridge, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046850

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

WAT046850 - µBondapak Phenyl Sentry Guard Cartridge, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046850
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.3
Chemistry Phenyl
Endcapped Yes
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L11
Units in Package 2/pkg
pH Range 2 - 8

info

WAT046860 - µPorasil Silica Guard Column, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046860

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

WAT046860 - µPorasil Silica Guard Column, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046860
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Guard Column
ID 3.9 mm
Length (mm) 20 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 2/pkg
pH Range 2 - 8

info

WAT046895 - Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046895

The Carbohydrate Sentry Guard Cartridge is used to extend and prolong the lifetime for the Carbohydrate Cartridge Column by removing chemical and particulate contaminants from the mobile phase stream.

WAT046895 - Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046895
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
USP Classification L20
Units in Package 2/pkg

info

WAT046910 - Holder kit for Cartridge and Guard Columns

Part Number: WAT046910

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

WAT046910 - Holder kit for Cartridge and Guard Columns
Part Number: WAT046910
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

info

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046970

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046970
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046980 - Symmetry C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046980

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046980 - Symmetry C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046980
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT047685 - Fluorescence Detector Performance Standard

Part Number: WAT047685

Alliance HPLC with Fluorescence Detector standards kit for system assessment. 1 Ampule (10 ml standard solution contains): - 0.10 mg/L Anthracene (+/- 5%) Purity >= 99% - Solution in 70% HPLC Grade Acetonitrile / 30% HPLC Grade Water, volume/volume

WAT047685 - Fluorescence Detector Performance Standard
Part Number: WAT047685
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Fluorescence (FLR)
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC -RI, FLR, Conductivity, Electrochemical

info

WAT050046 - VALVE,SWITCHING,LABPRO

Part Number: WAT050046
WAT050046 - VALVE,SWITCHING,LABPRO
Part Number: WAT050046
Products > Chromatography Consumables & Columns > Accessories

info

WAT051910 - Sep-Pak C18 Classic Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT051910

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns.

WAT051910 - Sep-Pak C18 Classic Cartridge, 360 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT051910
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Endcap End Capped
Format/Type Classic Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT052840

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT052840
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT052850 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT052850

The 4 µm small particle size of Nova-Pak bonded phases offers high resolution, more efficient and faster chromatography by using shorter columns, reducing solvent consumption or by using longer columns to resolve even the most complex mixture. Semi-preparative columns with 6µm particle size packings give you an unparalleled range of separation possibilities. Stringent QC procedures in our cGMP manufacturing facility ensure batch-to-batch reproducibility.

WAT052850 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT052850
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT052874 - AccQ-Tag Method Manual

Part Number: WAT052874

Manual detailing Waters AccQ-Tag™ Precolumn derivatization method for amino acid analysis.

WAT052874 - AccQ-Tag Method Manual
Part Number: WAT052874
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Fittings (pp 29)

info

WAT052880 - AccQ-Fluor Reagent Kit

Part Number: WAT052880

Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag-Fluor Reagent Pkg Includes: AccQTagFluor Reagent 1, 5X 6mL Vials Reagent 2A 5 X 3 mg vials, AccQFluor Reagent 2B 5 X 4mL vials. The components of this kit are not available separately.

WAT052880 - AccQ-Fluor Reagent Kit
Part Number: WAT052880
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid & Solid
Storage Room temp
System HPLC -UV

info

WAT052885 - AccQ-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT052885

Amino acid analysis is afundamental process in any protein research. Waters developed a new reagent specific for amino acid derivitization that provides enhanced quantitative accuracy and subpicomole detection for hydrolysate amino acids. We offer a system package consisting of an optimized instrument, prepackaged reagents and extensive documentation.

WAT052885 - AccQ-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT052885
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Amino Acid
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
Units in Package 1/pkg

info

WAT052890 - AccQ-Tag Eluent A

Part Number: WAT052890

Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag Eluent A Concentrate is available to purchase separetely in a 1 X 1L format.

WAT052890 - AccQ-Tag Eluent A
Part Number: WAT052890
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Eluent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT054200 - Symmetry C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: WAT054200

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054200 - Symmetry C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: WAT054200
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT054225

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT054225
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

WAT054230 - Symmetry C8 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: WAT054230

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054230 - Symmetry C8 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: WAT054230
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info WAT054260 - Sep-Pak® Reservoir adaptor 12/box
Part Number: WAT054260
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

info

WAT054265 - Sep-Pak Dry Sodium Sulfate, Plus Long Cartridge, 2.85 g Particle Size, 50/pkg

Part Number: WAT054265

Waters Sep-Pak Dry cartridges are packed with 2.85g of anhydrous sodium sulfate. These cartridges are designed to remove residual water from the SPE extract.

WAT054265 - Sep-Pak Dry Sodium Sulfate, Plus Long Cartridge, 2.85 g Particle Size, 50/pkg
Part Number: WAT054265
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Sodium Sulfate
Format/Type Plus Long Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Application Specific
Sorbent Substrate Sodium Sulfate
Sorbent Weight 2.85 g
Units In Package 50/pkg
Water Wettable Not Water Wettable

info

WAT054275 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT054275

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

WAT054275 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT054275
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054392 - Dextrans Standard

Part Number: WAT054392

A unique collection of 5 GPC standards (Gel Permeation Chromatography standards) for molecular weight determination. These Dextran GPC standards cover a molecular weight range from 5,000 Daltons to 750,000 Daltons

WAT054392 - Dextrans Standard
Part Number: WAT054392
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Life Science
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV