Product Listing:  WAT025656 - Sapphire Plunger   to   WAT060037 - Tube, inlet manifold to left inlet check valve

Sorted by Title
  Product    
info

WAT025656 - Sapphire Plunger

Part Number: WAT025656

Made from the highest quality sapphire, this plunger preserves the life span of the plunger seal. Precise roundness and smoothness tolerances minimize the wear of the plunger seal. Careful concentric alignment of the plunger within its stainless steel holder ensures that the sapphire rides directly into the center of the plunger seal, reducing wear of both parts. Included with the plunger is a pre-mounted C-Clip, which eliminates the need to remount this component.

WAT025656 - Sapphire Plunger
Part Number: WAT025656
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Plungers
Product Category Pumps
Systems
Products 510 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1

info

WAT025661 - Lubricating Oil, 150cc

Part Number: WAT025661

The oil lubricates the gears of the pump to ensure a smooth flow of solvent through the pump and then to the rest of the system.

WAT025661 - Lubricating Oil, 150cc
Part Number: WAT025661
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Pumps
Systems
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1

info

WAT025746 - Reference Valve Rebuild Kit

Part Number: WAT025746

This Reference Valve Rebuild Kit is a simple, cost-effective means for maintaining the reference valve that may have been added as an accessory to your Waters® pump. The kit provides all necessary parts and instructions to rebuild the reference valve and contains a diaphragm, actuator, and comprehensive instructions. The valve should be replaced or rebuilt every 12 months.

WAT025746 - Reference Valve Rebuild Kit
Part Number: WAT025746
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products 1515 HPLC Pump
1525 HPLC Pump
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
Replacement Schedule Annually

info

WAT026014 - Outlet Check Valve Rebuild Kit (225µL)

Part Number: WAT026014

Assemble and replace valves yourself at significant cost savings with this easy-to-use kit. Although ball and seat outlet check valves are also available pre-assembled, the rebuild kit gives you the option of self-maintenance at significant cost savings. The Ball and Seat Outlet Check Valve Rebuild Kit contains the ball and seat cartridge, gaskets, and comprehensive instructions. The valve should be replaced every 12 months.

WAT026014 - Outlet Check Valve Rebuild Kit (225µL)
Part Number: WAT026014
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Systems
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1

info

WAT026016 - Spring Loaded Outlet Check Valve Rebuild Kit

Part Number: WAT026016

Assemble and replace worn valves with this easy-to-use rebuild kit. This kit ensures maximum valve performance and reliability. Components are crafted with tight tolerances for superior quality. The kit contains PTFE seals, actuators, springs, filters, and comprehensive instructions.

WAT026016 - Spring Loaded Outlet Check Valve Rebuild Kit
Part Number: WAT026016
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 510 HPLC Pump
Replacement Schedule As Needed

info

WAT026613 - GFP Plunger Seal (Black)

Part Number: WAT026613

Made from high-performance, glass-filled polymer, the GFP Plunger Seal is manufactured with an internal spring that is designed to provide the correct pressure on the plunger, increasing the life of both the sapphire plunger and the seal itself. Waters® has determined that the Clear-100™ Seal is best suited to most applications and is the seal most commonly used in Waters solvent delivery systems and Performance Maintenance Kits. However, the GFP seal may be a better choice in certain applications.

WAT026613 - GFP Plunger Seal (Black)
Part Number: WAT026613
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Pumps
Systems
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
LC Module 1

info

WAT031795 - PEEK Tubing Cutter

Part Number: WAT031795

Cut PEEK tubing quickly and easily with this versatile tubing cutter.

WAT031795 - PEEK Tubing Cutter
Part Number: WAT031795
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category Systems
Products LC Module 1
Replacement Schedule No

info

WAT031870 - Plunger Seal Wash Kit 100µL

Part Number: WAT031870

The Plunger Seal Wash Kit (100µL) contains the following components: one wash seal insert tool, three polypropylene 1/16 in. tee, six adapter fittings, one plunger wash seal 100µL, two retaining rings, one Teflon® tube (10ft).

WAT031870 - Plunger Seal Wash Kit 100µL
Part Number: WAT031870
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Pumps
Systems
Products 1515 HPLC Pump
1525 HPLC Pump
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1
Replacement Schedule As Needed

info

WAT033383 - 100µL Syringe, Rheodyne™

Part Number: WAT033383

The 100µL Rheodyne Syringe is a low pressure microsyringe, 2 inches long. 22 Gauge, and has a square end (90°) tip style.

WAT033383 - 100µL Syringe, Rheodyne™
Part Number: WAT033383
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products Rheodyne Injector

info

WAT033388 - Needle Luer 22AWG (.006 ID)

Part Number: WAT033388

This spare part is a Waters Quality part.

WAT033388 - Needle Luer 22AWG (.006 ID)
Part Number: WAT033388
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products Rheodyne Injector
Replacement Schedule As Needed

info

WAT033446 - Rheodyne 9125 PEEK Injector

Part Number: WAT033446

The Rheodyne 9125 PEEK Injector is non-metallic with a Tefzel rotor and a stator made of PEEK. The maximum operating pressure for this injector is 5000psi.

WAT033446 - Rheodyne 9125 PEEK Injector
Part Number: WAT033446
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Pumps
Products 626 LC System
Replacement Schedule No

info

WAT033679 - Ball and Seat Inlet Check Valve

Part Number: WAT033679

This valve assembly saves installation time and reduces the handling of small parts, as compared with the corresponding valve rebuild kit. The unit offers convenience and ease of installation to users of Waters® 510, 515, and 600 pumps, as well as the LC Module 1 system. All Waters check valves are leak-tested at the factory and assembled in a clean environment to ensure the delivery of a tightly-sealed and reliable part.

WAT033679 - Ball and Seat Inlet Check Valve
Part Number: WAT033679
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Systems
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1
Replacement Schedule As Needed

info

WAT045400 - Strain Gauge Transducer Assembly

Part Number: WAT045400

The strain gauge transducer is the most advanced and reliable pressure-detection device in the industry today. As compared with the Bourdon tube transducer, it offers enhanced accuracy and linearity and contains no light bulbs or moving parts to fail.

WAT045400 - Strain Gauge Transducer Assembly
Part Number: WAT045400
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Systems
Products LC Module 1
Replacement Schedule As Needed

info

WAT045424 - High Pressure Motorized Valve Rebuild Kit

Part Number: WAT045424

The high pressure valve rebuild kit contains all of the Waters Quality Parts® required to fully rebuild the valves of the Waters® 717/717 Plus Autosampler, 2690/2695 Separations Modules, 2690D/2695D Separations Modules and LC Module 1 system. The spool is crafted to precise hardness, smoothness, and alignment specifications. The high-pressure valve seals are made of proprietary materials and then packed in anti-static bags to further minimize the chance of particulate contamination. The rebuild kit contains a PTFE O-ring, seal, spool, high pressure seals, and comprehensive instructions.

WAT045424 - High Pressure Motorized Valve Rebuild Kit
Part Number: WAT045424
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
717/717 Plus Autosampler
LC Module 1
Replacement Schedule As Needed

info

WAT045427 - HPMV Tool Kit

Part Number: WAT045427

This kit contains the special tools required to install the seals that came in the HP Valve Rebuild Kit (WAT045424). The kit contains the following tools: seal punch, seal guide, wood screw.

WAT045427 - HPMV Tool Kit
Part Number: WAT045427
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category Injectors
Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule No

info

WAT045438 - High Pressure Motorized Valve Assembly

Part Number: WAT045438

The High Pressure Motorized Valve (HPMV) is a three-way valve that has two common ports and one controllable port. The HPMV is used in two of the three valve positions in the Fluids Pak: V1 (High Pressure Inject Valve) and V2 (High Pressure Syringe Valve). The basic valve is driven by a stepper motor.

WAT045438 - High Pressure Motorized Valve Assembly
Part Number: WAT045438
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Injectors
Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
LC Module 1
Replacement Schedule As Needed

info

WAT045559 - Seal Pack and Needle Replacement Kit

Part Number: WAT045559

The Seal Pack and Needle Replacement Kit contains the following parts: one stainless steel annealed ferrule, one short compression screw (for old style injector only), one needle, one long compression screw (for new style injector only), one seal pak assembly, and the installation instructions.

WAT045559 - Seal Pack and Needle Replacement Kit
Part Number: WAT045559
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Systems
Products LC Module 1

info

WAT045584 - 717 Sample Loop, 200µL

Part Number: WAT045584

The 200µL sample loop is the standard sample loop that is installed in the 717 Plus Autosampler and it is also used in the LC Module 1.

WAT045584 - 717 Sample Loop, 200µL
Part Number: WAT045584
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Injectors
Systems
Products 717/717 Plus Autosampler
LC Module 1
Replacement Schedule As Needed

info

WAT047491 - Flow Cell Replacement Kit (16ul)

Part Number: WAT047491

The 16µL Flow Cell Replacement kit contains the following items: (1) 16µL flow cell, (1) gasket (upper), and (1) gasket (lower), 4 wells.

WAT047491 - Flow Cell Replacement Kit (16ul)
Part Number: WAT047491
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 474 Scanning Fluorescence Detector

info

WAT051518 - Gradient Mixer, Single Stage

Part Number: WAT051518

The Single Stage Gradient Mixer insures complete mixing of solvents in a gradient system. It is a flow-through device that responds rapidly to solvent composition changes due to its low volume.

WAT051518 - Gradient Mixer, Single Stage
Part Number: WAT051518
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 510 HPLC Pump
PrepLC 2000
PrepLC 4000
Replacement Schedule No

info

WAT052256 - Needle Luer 22AWG (.016 ID)

Part Number: WAT052256

This spare part is a Waters Quality part.

WAT052256 - Needle Luer 22AWG (.016 ID)
Part Number: WAT052256
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products Rheodyne Injector
Replacement Schedule As Needed

info

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT

Part Number: WAT052586

The Waters® Performance Maintenance Kit for the 996/2996/ACQUITY 2996 PDA Detector contains all of the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts:a PerformancePLUS™ Long Life Lamp which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first, and an air filter.

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT
Part Number: WAT052586
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Capillary LC
Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector
ACQUITY UPLC 2996 PDA Detector
CapLC 2996
Replacement Schedule Annually

info

WAT052587 - 515 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052587

The Waters® Performance Maintenance Kit for the 515 pump contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: two Clear-100™ plunger seals, two standard sapphire plungers, one solvent filter, one diffuser, four PerformancePLUS™ Check Valve Cartridges and thin wall Teflon Tubing.

WAT052587 - 515 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052587
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Pumps
Products 515 HPLC Pump
Replacement Schedule Annually

info

WAT052666 - 486 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052666

The Waters® Performance Maintenance Kit for the 486 Tunable UV/Visible Absorbance Detector contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: one lens, one air filter, one lithium battery, one fuse, and one PerformancePLUS™ Long Life Lamp, which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first.

WAT052666 - 486 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052666
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Detectors
Products 486 Tunable UV/Visible Absorbance Detector
Replacement Schedule Annually

info

WAT052669 - 717 PERFORMANCE MAINTENANCE KIT

Part Number: WAT052669

The Waters® Performance Maintenance Kit for the 717 Autosampler contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance. The Waters® Performance Maintenance Kit includes the following parts: one seal pack replacement kit, one syringe, one filter insert assembly, one 2.3mm x 11.5mm filter, and two 2mm x 7mm filters.

WAT052669 - 717 PERFORMANCE MAINTENANCE KIT
Part Number: WAT052669
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Injectors
Replacement Schedule Annually

info

WAT052675 - 600 100µL PERFORMANCE MAINTENANCE KIT

Part Number: WAT052675

The Waters® Performance Maintenance Kit for the 600 Multisolvent Delivery System contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: two Clear-100™ plunger seals, two oriented sapphire plungers, four solvent filters, two PerformancePLUS™ Check Valve Cartridges, one reference valve rebuild kit and one inlet drawoff rebuild kit.

WAT052675 - 600 100µL PERFORMANCE MAINTENANCE KIT
Part Number: WAT052675
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Pumps
Products 600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
Replacement Schedule Annually

info

WAT055840 - Rheodyne Inject Vlv, 7725i, spare

Part Number: WAT055840

The Rheodyne 7725i Inject Valve is available as an option for the 616 LC System. The 7725i is a stainless steel seven port injection valve in which the sample is loaded through a built-in needle port in the front of the valve. It is also used in the Preparative Chromatography Rack for the 25X5 series pumps.

WAT055840 - Rheodyne Inject Vlv, 7725i, spare
Part Number: WAT055840
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Injectors
Pumps
Products 2545 Quaternary Gradient Pump
FlexInject Manual Dual Injector Module
Rheodyne Injector
Replacement Schedule No

info

WAT057919 - Analytical Cell Assembly, 10mm

Part Number: WAT057919

The Analytical Cell Assembly has a Reverse Taper Beam flow cell design with a 10mm path length and a pressure rating of 1000psi.

WAT057919 - Analytical Cell Assembly, 10mm
Part Number: WAT057919
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector

info

WAT057923 - Cell Lens Assembly, 2/Pkg

Part Number: WAT057923

The Cell Lens Assembly is used in the analytical, high pressure analytical (MS), and non-metallic flow cells on both sides of the flow cell body. It is used on the light exit side of the cell in the semi-prep and microbore flow cells.

WAT057923 - Cell Lens Assembly, 2/Pkg
Part Number: WAT057923
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector
Replacement Schedule As Needed

info

WAT060037 - Tube, inlet manifold to left inlet check valve

Part Number: WAT060037

This spare part is a Waters Quality part.

WAT060037 - Tube, inlet manifold to left inlet check valve
Part Number: WAT060037
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Pumps
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System