Product Listing:  186006349 - 2-AB Glycan Performance Test Standard   to   186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Sorted by Title
  Product    
info

186006349 - 2-AB Glycan Performance Test Standard

Part Number: 186006349

The 2-AB Glycan Performance Test Standard is 2-AB labeled Human IgG and is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC BEH Glycan, 1.7 µm Columns. It comes in a Waters TruView vial as a lyophilized powder. There is 228 pmol total/vial. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006349 - 2-AB Glycan Performance Test Standard
Part Number: 186006349
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

186006363 - Reversed-Phase QC Reference Material

Part Number: 186006363

The Quality Control Reference Materials portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientist. The Reversed-Phase QC Reference Material is a significantly complex reference material mixture in that it contains compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. It can be used with a variety of column chemistries and dimensions, and system hardware. The Reversed-Phase QC Reference Material contains 7 compounds including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7. This standard mix should be used to confirm the benchmark performance of your analytical HPLC or UPLC system. This particular QC Reference Material is a specially formulated mix that includes a void marker, neutral, acidic and basic compounds. These compounds were vigorously tested and evaluated and chosen because they provide the following advantages: – Excellent benchmark – Good peak shape on UV – Acceptable for use on a variety of column

186006363 - Reversed-Phase QC Reference Material
Part Number: 186006363
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Column Chemistry C18 RP
Detector UV
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

186006414 - XSelect HSS C18 Method Validation Kit, 100Å, 5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186006414

The HSS C18 packing is the most stable commercially available bonded phase and does not suffer from peak shape issues that plague older stationary phases that rely upon steric protection (and lack of endcapping) to produce stability at low pH. The HSS C18 HPLC columns are fully scalable and are completely transferable to UPLC separations.

186006414 - XSelect HSS C18 Method Validation Kit, 100Å, 5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186006414
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 8

info

186006505 - ACQUITY UPLC Protein BEH SEC Column, 125Å, 1.7 µm, 4.6 mm X 150 mm, 1K - 80K, 1/pkg

Part Number: 186006505

Based upon the highly successful BEH particle technology, the new patent pending ACQUITY UPLC BEH125 SEC column represents the first commer­cially available sub 2 ìm SEC chemistry. Fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 1000 to 80,000 Daltons, the total system solution will routinely deliver fast, accurate aggregate determinations up to 10 times quicker that traditional HPLC-based SEC methods.

186006505 - ACQUITY UPLC Protein BEH SEC Column, 125Å, 1.7 µm, 4.6 mm X 150 mm, 1K - 80K, 1/pkg
Part Number: 186006505
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Protein
Chemistry SEC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Molecular Weight Range 1K - 80K
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 125Å
QC Tested Protein
Silanol Activity Low
Surface Area 220
System UPLC/UHPLC
Technology BEH
USP Classification L33
Units in Package 1/pkg
pH Range 1 - 8

info

186006516 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186006516

The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186006516 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186006516
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186006518 - BEH200 SEC Protein Standard Mix

Part Number: 186006518

The BEH200 SEC Protein Standard Mix is a 5 component protein mixture (Thyroglobulin, IgG, BSA, Myoglobin, Uracil) used to benchmark ACQUITY UPLC BEH200 SEC, 1.7 µm Columns. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006518 - BEH200 SEC Protein Standard Mix
Part Number: 186006518
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

186006519 - BEH125 Protein Standard Mix

Part Number: 186006519

The BEH125 SEC Protein Standard Mix is a 4 component protein mixture (Thyroglobulin, Ovalbumin, Ribonuclease A and Uracil) used to benchmark ACQUITY UPLC BEH125 SEC, 1.7 µm Columns. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006519 - BEH125 Protein Standard Mix
Part Number: 186006519
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

186006527 - nanoACQUITY UPLC Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg

Part Number: 186006527

The nanoACQUITY UPLC 2G Trap Columns (10,000 psi) are designed to minimize peak broadening while maximizing chromatographic efficiency. They can be used in a variety of 1D (low pH) nano flow applications. For 2D applications where the first dimension utilizes high pH, Waters recommends the use of a 2D trap.

186006527 - nanoACQUITY UPLC Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg
Part Number: 186006527
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format nanoACQUITY Trap 10K psi MV
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System UPLC/UHPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186006552 - Intact mAb Mass Check Standard

Part Number: 186006552

Analysis of intact proteins by MS is a powerful approach for protein identification and assignment of protein modifications. The Intact mAb Mass Check Standard is a LC/MS standard used as a qualitative tool for intact mass analysis. It is an intact mouse protein purified by Protein-A with a known molecular weight, ideal for higher molecular weight intact mass measurements. It is provided in a Waters Max Recovery Vial PN 18600327c. This standard is designed to be used for routine MS optimization, system setup and performance testing.

186006552 - Intact mAb Mass Check Standard
Part Number: 186006552
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry Polar RP
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
Storage Frozen -20 C
System LC/MS

info

186006582 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186006582

Designed and tested for the ACQUITY UPC2 system, the Viridis sub-2-µm and 3.5 µm columns demonstrate high efficiency and resolution. The reduction and control of surface silanol activity on Viridis particles delivers, under SFC conditions, excellent peak shapes — without the use of mobile-phase additives — even for well-retained basic achiral compounds.

186006582 - Viridis BEH 2-Ethylpyridine Column, 130Å, 1.7 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186006582
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
% Carbon Load 9
Chemistry 2-Ethylpyridine
Endcapped No
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Medium
Surface Area 185
System UPC2/SFC
Technology BEH
Units in Package 1/pkg

info

186006727 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006727

XSelect CSH C18 columns are general purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006727 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006727
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006732 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006732

Designed to maximize selectivity differences, the XSelect CSH Fluoro-Phenyl column provides you with maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006732 - XSelect CSH Fluoro Phenyl XP Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006732
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186006738 - XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186006738

XSelect HSS C18 is a general purpose, high performance C18 chemistry with exceptional retention and peak shape for all compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006738 - XSelect HSS C18 XP Column, 100Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186006738
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

186006841 - 2-AB Dextran Calibration Ladder

Part Number: 186006841

In order to take full advantage of the BEH glycan column, Waters created the 2-aminobenzamide labeled 2-AB Dextran Calibration Ladder Standard to assist glycan profiling. Glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the 2AB-labeled dextran ladder and assigned with glucose unit (GU) values. Waters 2-AB labeled Dextran Calibration Ladder is different than the existing commercial offerings. The average molecular weight of the glucose homopolymer is higher (~4,500 Dalton), therefore, the workable GU value range is twice as much as the other dextran ladder standards; the observed GU goes from 2 to 30. This feature improves the large glycan retention time assignment.

186006841 - 2-AB Dextran Calibration Ladder
Part Number: 186006841
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186006846 - MS Cleaning Solution

Part Number: 186006846

For use in cleaning MS parts, 500mL MS cleaning solution

186006846 - MS Cleaning Solution
Part Number: 186006846
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

186006861 - Tuning Solution/Gradient Performance, Sensitivity and Precision

Part Number: 186006861

Routine Use MS Standard for Single and Triple Quads. Perform tuning gradient performance sensititivty and precision testing. Contains Acetominophen, Caffeien, Sulfadimethoxine, Verapamil, Chloramphenicol, and 17-?-hydroxy-progesterone

186006861 - Tuning Solution/Gradient Performance, Sensitivity and Precision
Part Number: 186006861
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006938

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006938
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006939

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006939
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186006943 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006943

Waters CSH130 C18 based particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. Packed in ultra-low dispersion hardware, XSelect CSH130 C18 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006943 - XSelect Peptide CSH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006943
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

186006961 - Waters Positive Pressure-96 Processor

Part Number: 186006961

Waters Positive Pressure-96 processor offers state-of-the-art operation for moving liquids through SPE 96-well devices. Each of the 96 holes in the processor manifold are restricted in order to maintain constant pressure, even if all the plate wells positions are not filled. SPE sample processing by positive pressure significantly improves the flow of viscous samples through SPE packed bed by providing highly uniform flow from well-to-wel,l which will ultimately improve the reproducibility of analytes SPE recoveries.

186006961 - Waters Positive Pressure-96 Processor
Part Number: 186006961
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

Waters Positive Pressure-96 processor offers state-of-the-art operation for moving liquids through SPE 96-well devices. Each of the 96 holes in the processor manifold are restricted in order to maintain constant pressure, even if all the plate wells positions are not filled. SPE sample processing by positive pressure significantly improves the flow of viscous samples through SPE packed bed by providing highly uniform flow from well-to-wel,l which will ultimately improve the reproducibility of analytes SPE recoveries.

info

186006963 - LCMS QC Reference Standard

Part Number: 186006963

The LCMS QC Reference Material is a 9 component mix of Acetaminophen, Caffeine, Sulfaguanidine, Sulfadimethoxine, Val,-Tyr-Val, Verapamil, Terfenadine, Leucine-Enkephalin and Reserpine packaged in a Waters vial. This standard provides a comprehensive reference for the use with LC/MS or MS instrumentation with a wide variety of conditions and methods.

186006963 - LCMS QC Reference Standard
Part Number: 186006963
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186007034 - GlycoWorks 2-AB Labeling Reagent Kit

Part Number: 186007034

The GlycoWorks Reagent Kit is an inclusive kit that provides reagents needed to follow the GlycoWorks High-throughput or Single Use Kit protocols. When purchasing the 176 kit part numbers this kit is included but can also be purchased separately.

186007034 - GlycoWorks 2-AB Labeling Reagent Kit
Part Number: 186007034
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging Kit
Product Type Kit
Shipping Formulation Liquid & Solid
Storage Room temp
System LC/MS

info

186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg

Part Number: 186007080

The GlycoWorks HILIC 1cc Cartridge Pack contains 20 1cc cartridges for a total of 10 reactions for low sample volume environments. The cartridges are dual purpose; they can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each cartridge is packed with 10 mg of Waters HILIC Solid Phase Extraction (SPE).

186007080 - GlycoWorks HILIC 1cc Cartridge, 20/pkg
Part Number: 186007080
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 20/pkg
Product Type Kit
Shipping Formulation Liquid & Solid
Storage Room temp
System LC/MS

info

186007081 - Waters Ammonium Formate Solution – Glycan Analysis

Part Number: 186007081

This is a concentrated version of the 50mM Ammonium Formate buffer that is recommended to be used with the Biopharm/Glycan system, using the UPLC H-class and the ACQUITY UPLC BEH Glycan Column. This buffer contains 10ml of 5050 mM Ammonium Formate in a Water w/ 3.8% Formic acid matrix. This allows the end user to directly pour the concentrate into a 1L bottle of LCMS grade water for the correct concentration of 50 mM at a pH of 4.4.

186007081 - Waters Ammonium Formate Solution – Glycan Analysis
Part Number: 186007081
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector Fluorescence (FLR)
Product Type Mobile Phase
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System LC -RI, FLR, Conductivity, Electrochemical

info

186007114 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186007114

CORTECS C18+ columns are general purpose, high efficiency C18 columns based on a solid-core particle that are designed to deliver excellent peak shape for basic analytes at low pH.

186007114 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186007114
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007116 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186007116

CORTECS C18+ columns are general purpose, high efficiency C18 columns based on a solid-core particle that are designed to deliver excellent peak shape for basic analytes at low pH.

186007116 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186007116
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007122 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186007122

CORTECS C18+ columns are general purpose, high efficiency C18 columns based on a solid-core particle that are designed to deliver excellent peak shape for basic analytes at low pH.

186007122 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186007122
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info 186007238 - nanoACQUITY UPLC Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg
Part Number: 186007238
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
Chemistry C18
Format nanoACQUITY Trap 10K psi MV
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Pore Size 100Å
Silanol Activity Low
System Nano/Micro
Units in Package 1/pkg
pH Range 1 - 10

info

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186007265

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186007265
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007270

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007270
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11