Product Listing:  186003839 - AccQ-Tag Ultra Eluent B   to   186004681 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pkg

Sorted by Title
  Product    
info

186003839 - AccQ-Tag Ultra Eluent B

Part Number: 186003839

mino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Eluent B is a component of the UPLC® Amino Acid Analysis Application Solution. Eluent B is a concentrate of 950 ml.

186003839 - AccQ-Tag Ultra Eluent B
Part Number: 186003839
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Eluent
Shipping Formulation Liquid
Storage Room temp
System UPLC

info

186003854 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186003854

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186003854 - SunFire C18 OBD Prep Column, 100Å, 10 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186003854
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003886C - LCGC Certified Amber Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186003886C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186003886C - LCGC Certified Amber Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186003886C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2795
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Amber Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186003943 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003943

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003943 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003943
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003952 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003952

Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186003952 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186003952
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003953

Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003953
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003962

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003962
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003964

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003964
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003966 - Sep-Pak C18 96-well Plate, 40 mg Sorbent per Well, 1/pk

Part Number: 186003966

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns. The innovative 96-well plate design is compatible with most liquid handling and SPE automation systems and is an ideal compliment to high througput laboratory applications.

186003966 - Sep-Pak C18 96-well Plate, 40 mg Sorbent per Well, 1/pk
Part Number: 186003966
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Endcap End Capped
Format/Type 96-well Plate
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 40 mg
Units In Package 1/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003975

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003975
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003976

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003976
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186003977 - ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003977

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003977 - ACQUITY UPLC BEH Shield RP18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003977
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 12

info

186003980 - ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003980

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003980 - ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003980
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity High
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 9

info

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186004021

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186004021
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004032 - MassPREP Micro Desalting Column

Part Number: 186004032

"The MassPREP on-line desalting column can effectively desalt proteins prior to LC-MS analyses. Because non-volatile salts (e.g., NaCl) cansuppress ionization of intact proteins leading to poor detection sensitivity, it is important to remove or significantly minimize the introduction ofthese compounds into the mass analyzer. The reversed-phase phenyl material contained in MassPREP on-line column successfully “traps” proteins,allowing the salts to be washed to waste prior to protein elution into the mass spectrometer. With an optimized LC-MS method, cycle times as lowas 4 minutes (for intact antibody) and 10 minutes (for reduced antibody) are achievable."

186004032 - MassPREP Micro Desalting Column
Part Number: 186004032
Brand: MassPrep

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Chemistry Phenyl
Endfitting Type Direct-Connect
Format Direct Connect Column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 1M
Particle Shape Spherical
Particle Size (dp) 20 µm
Particle Substrate Polymethacrylate
Pore Size 1000Å
Units in Package 1/pkg
pH Range 2 - 12

info

186004051 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: 186004051

Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride counter-ion in the standard Sep-Pak Accell Plus QMA cartridges interferes with the analysis. These Light-style cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.

186004051 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: 186004051
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA Carbonate
Format/Type Plus Light Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 130 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 2 - 8 pH

info

186004108 - Clear Glass Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 20 mL Volume, 100/pkg

Part Number: 186004108

These vials are produced to tight dimensional tolerance for use in autosamplers.

186004108 - Clear Glass Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 20 mL Volume, 100/pkg
Part Number: 186004108
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Closure Type Screw Neck
Format Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 20 mL

info

186004112 - Polypropylene 12 x 32mm Screw Neck Vial, with Polyethylene Septumless Cap, 300 µL Volume, 100/pkg

Part Number: 186004112

Clean polypropylene-molded vial, preferred in applications where there is a concern that compound or molecule may stick to a polar glass surface. This vial is a cost effective alternative to glass.

186004112 - Polypropylene 12 x 32mm Screw Neck Vial, with Polyethylene Septumless Cap, 300 µL Volume, 100/pkg
Part Number: 186004112
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Polypropylene
Septa Type Polyethylene Septumless Cap
Units in Package 100/pkg
Volume Capacity 300 µL

info 186004169 - Polyethylene septumless screw cap for 12 x 32mm vials, 100 pack
Part Number: 186004169
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Color White
Dimensions 12 x 32mm
Format Cap
Septa Type Polyethylene Septumless Cap
Units in Package 100/pkg

info

186004475 - Oasis Method Development 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: 186004475

The Oasis Method Development µElution Plate is specifically designed to take the guesswork out of SPE method development. The patented 96-well plate format contains 3 rows each of the four Oasis mixed-mode, ion-exchange chemistries: strong and weak anion exchangers (MAX and WAX) and strong and weak cation exchangers (MCX and WCX). Sample preparation method development can be quickly and easily achieved with the use of only two SPE protocols. The Oasis µElution Sorbent Selection plate is compatible with most liquid-handling robotic systems for automated, high throughput SPE.

186004475 - Oasis Method Development 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Part Number: 186004475
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Method Development
Format/Type 96-well µElution Plate
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 2 mg
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg

Part Number: 186004498

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg
Part Number: 186004498
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004504

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004504
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004540 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 46 mg Sorbent per Cartridge, 40 µm Particle Size, 50/pk

Part Number: 186004540

Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride counter-ion in the standard Sep-Pak Accell Plus QMA cartridges interferes with the analysis. These Light-style cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.

186004540 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 46 mg Sorbent per Cartridge, 40 µm Particle Size, 50/pk
Part Number: 186004540
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA Carbonate
Format/Type Plus Light Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 40 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 46 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 2 - 8 pH

info

186004544 - PoraPak Rxn CX 60 cc Vac Cartridge, 5 g Sorbent per Cartridge, 80 µm Particle Size, 10/pk

Part Number: 186004544

PoraPak Rxn CX is a polymer-based strong cation-exchange resin designed specifically for post synthesis cleanup of reaction mixtures in drug discovery.

186004544 - PoraPak Rxn CX 60 cc Vac Cartridge, 5 g Sorbent per Cartridge, 80 µm Particle Size, 10/pk
Part Number: 186004544
Brand: PorarPak Rxn

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 60 cc
Chemistry CX
Format/Type Vac Cartridge
Ion Exch. Capacity 1 meq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 80 µm
Sorbent Substrate Copolymer
Sorbent Weight 5 g
Units In Package 10/pkg
pH Range 0 - 14 pH

info

186004618 - Certified Sep-Pak tC18 3 cc Vac Cartridge, 200 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pkg

Part Number: 186004618

Certified Sep-Pak C18 Vac cartridges contain a hydrophobic, reverse-phase, silica-based bonded phase that is used to adsorb analytes of even weak hydrophobicity from aqueous solutions. The C18 sorbent is made using the most reproducible bonding technology available, utilizing monofunctional silane chemistry. This sorbent offers a unique selectivity and excellent recovery of anlytes, and is recommended as a general purpose SPE phase for both polar and non-polar analytes. Typical applications include extraction of drugs and their metabolites in serum, plasma or urine, desalting of peptides, isolation of trace organics in environmental water samples and organic acids in beverages. Certified Sep-Pak C18 cartridges are quality controlled to ensure reproducible separations. The cartridges provide superior performance for ultra-low level analyte detection by reducing the potential for background interferences found in many SPE devices. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

186004618 - Certified Sep-Pak tC18 3 cc Vac Cartridge, 200 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pkg
Part Number: 186004618
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry TC18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 200 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004623

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186004623
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Application Protein
Chemistry C4
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004629

VanGuard pre-columns are the first guard column devices designed for routine use at pressures up to 15000 psi (1030 bar) in applications run on the ACQUITY UPLC System. This specific offering contains Waters patented BEH Technology C18, 300A pore, 1.7um particles based and each batch is specifically QC tested with a peptide map to help ensure consistent performance and increased analytical column life.

186004629 - ACQUITY UPLC Peptide BEH C18 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186004629
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 90
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info 186004631 - Assembled 12 x 32 mm Total Recovery Vial with PTFE/Silicone Septum 100 pack
Part Number: 186004631
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2690
Waters 2695
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 1.1 mL

info

186004659 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 3 mm X 30 mm, 1/pkg

Part Number: 186004659

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

186004659 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 3 mm X 30 mm, 1/pkg
Part Number: 186004659
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004681 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186004681

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations.

186004681 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186004681
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8