Product Listing:  186000289 - Symmetry C4 Column, 300Å, 5 µm, 4.6 mm X 250 mm, 1/pkg   to   186000841 - Black, Screw Neck Cap and PTFE/silicone Septum, 100/pkg

Sorted by Title
  Product    
info

186000289 - Symmetry C4 Column, 300Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000289

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

186000289 - Symmetry C4 Column, 300Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000289
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.8
Application Protein
Chemistry C4
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 300Å
Silanol Activity Low
Surface Area 110
System HPLC
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 8

info

186000302 - Clear Glass 12 x 32mm Snap Neck Total Recovery Vial, 1 mL Volume, 100/pkg

Part Number: 186000302

Waters offers a selection of snap cap vials and snap caps/septa.

186000302 - Clear Glass 12 x 32mm Snap Neck Total Recovery Vial, 1 mL Volume, 100/pkg
Part Number: 186000302
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified Not Certified
Closure Type Snap Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Units in Package 100/pkg
Volume Capacity 1 mL

info

186000305 - Blue, 12 x 32mm Screw Neck Cap and preslit PTFE/silicone Septum, 100/pkg

Part Number: 186000305

Dark blue polyethylene screw cap with bonded slit septum for 12 x 32 mm vials.

186000305 - Blue, 12 x 32mm Screw Neck Cap and preslit PTFE/silicone Septum, 100/pkg
Part Number: 186000305
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Color Blue
Dimensions 12 x 32mm
Format Cap and preslit PTFE/silicone Septum
Units in Package 100/pkg

info

186000307DV - Deactivated Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186000307DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

186000307DV - Deactivated Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186000307DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2690
Waters 2695
Waters 2790
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Deactivated Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186000327C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186000327C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000327C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186000327C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2795
Waters Acquity
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186000327DV - Deactivated Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1.5 mL Volume, 100/pkg

Part Number: 186000327DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

186000327DV - Deactivated Clear Glass 12 x 32mm Screw Neck Max Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1.5 mL Volume, 100/pkg
Part Number: 186000327DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2795
Waters Acquity
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Max Recovery Vial
GlassType Deactivated Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1.5 mL

info

186000349DV - 96 well plate with deactivated 700uL glass inserts, 1pkg

Part Number: 186000349DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

186000349DV - 96 well plate with deactivated 700uL glass inserts, 1pkg
Part Number: 186000349DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format 96 Well Plates
GlassType Deactivated
Units in Package 1/pkg
Volume Capacity 700 µL

info

186000384C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and PTFE/silicone Septum , 1 mL Volume, 100/pkg

Part Number: 186000384C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000384C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and PTFE/silicone Septum , 1 mL Volume, 100/pkg
Part Number: 186000384C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and PTFE/silicone Septum
Units in Package 100/pkg
Volume Capacity 1 mL

info

186000385C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg

Part Number: 186000385C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000385C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg
Part Number: 186000385C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1 mL

info

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186000404

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186000404
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000424 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186000424

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000424 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186000424
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000432 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000432

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000432 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000432
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000434 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000434

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000434 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000434
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000435 - XTerra RP 8 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000435

XTerra RP8 columns are general purpose, hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186000435 - XTerra RP 8 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000435
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

186000438 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000438

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000438 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000438
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000440 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000440

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000440 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000440
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000442

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000442
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000478 - XTerra MS C18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000478

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000478 - XTerra MS C18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000478
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000480 - XTerra Shield RP18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000480

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000480 - XTerra Shield RP18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000480
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000486 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000486

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000486 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000486
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000490

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000490
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000491 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000491

XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000491 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000491
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186000492 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000492

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000492 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000492
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000494 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000494

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000494 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000494
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000495 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000495

XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000495 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000495
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186000496 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000496

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000496 - XTerra Shield RP18 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000496
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186000632 - XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pkg

Part Number: 186000632

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000632 - XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pkg
Part Number: 186000632
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 2.1 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 12

info

186000776 - Oasis MCX 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 60 µm Particle Size, 30/pk

Part Number: 186000776

The 6 cc Oasis MCX cartridges contain the Oasis MCX, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. Since the Oasis MCX sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. The 60 µm particle size is recommended when working with viscous samples. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

186000776 - Oasis MCX 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 60 µm Particle Size, 30/pk
Part Number: 186000776
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 6 cc
Chemistry MCX
Format/Type Vac Cartridge
Ion Exch. Capacity 1 meq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 60 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 500 mg
Units In Package 30/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

186000840 - Clear Glass 15 x 45mm Screw Neck Vial, 4 mL Volume, 100/pkg

Part Number: 186000840

For more information on the complete line of Waters vials, please download Waters latest brochure on vials and accessories.

186000840 - Clear Glass 15 x 45mm Screw Neck Vial, 4 mL Volume, 100/pkg
Part Number: 186000840
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Bruker
Kontron
Perkin-Elmer
Shimadzu
Tosoh
Unicam
Waters 700 Series
Waters GPC2000
Certified Not Certified
Closure Type Screw Neck
Dimensions 15 x 45mm
Format Vial
GlassType Clear Glass
Units in Package 100/pkg
Volume Capacity 4 mL

info

186000841 - Black, Screw Neck Cap and PTFE/silicone Septum, 100/pkg

Part Number: 186000841

This septum is electron bonded to the cap and will not come dislodged during shipment or use.

186000841 - Black, Screw Neck Cap and PTFE/silicone Septum, 100/pkg
Part Number: 186000841
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Bruker
Kontron
Perkin-Elmer
Shimadzu
Tosoh
Unicam
Waters 700 Series
Certified Not Certified
Closure Type Screw Neck
Color Black
Format Cap and PTFE/silicone Septum