Product Listing:  WAT084560 - Inline Precolumn Filter Kit   to   WAT084624 - Resolve C18 Radial-Pak Cartridge, 90Å, 5 µm, 8.0 mm X 100 mm, 1/pkg

Sorted by Best Sellers
  Product    
info

WAT084560 - Inline Precolumn Filter Kit

Part Number: WAT084560

The In-Line Precolumn Filter is a 2µm filter that is placed before the column to help extend the life and preserve the chemistry of the column.

WAT084560 - Inline Precolumn Filter Kit
Part Number: WAT084560
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Systems
Products LC Module 1
Replacement Schedule As Needed

info

WAT094226 - Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk

Part Number: WAT094226

The 3 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT094226 - Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk
Part Number: WAT094226
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 60 mg
Units In Package 100/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

WAT082823 - Gradient Proportioning Valve

Part Number: WAT082823

The Gradient Proportioning Valve Assembly is a set of four 2-way valves, which features opening and closing rates and aperture sizes of an exceptionally tight tolerance. The four inlet valves are actuated by solenoids that have precise electrical characteristics to help reduce heat buildup and protect the system from outgassing. The gradient proportioning valve provides exact, reproducible mixing of up to four different solvents.

WAT082823 - Gradient Proportioning Valve
Part Number: WAT082823
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products PrepLC 4000
Replacement Schedule No

info

205000436 - Flow Splitter, 2.0-8.0mL, 100:1

Part Number: 205000436

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000436 - Flow Splitter, 2.0-8.0mL, 100:1
Part Number: 205000436
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

WAT043395 - Sep-Pak C18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 55-105 µm Particle Size, 30/pk

Part Number: WAT043395

Silica-based octadecyl bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages.

WAT043395 - Sep-Pak C18 6 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 55-105 µm Particle Size, 30/pk
Part Number: WAT043395
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 6 cc
Chemistry C18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 500 mg
Units In Package 30/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT023590 - Sep-Pak C18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk

Part Number: WAT023590

Sep-Pak C18 Vac cartridges contain a hydrophobic, reverse-phase, silica-based bonded phase that is used to adsorb analytes of even weak hydrophobicity from aqueous solutions. The Sep-Pak C18 sorbent is made using the most reproducible bonding technology available, utilizing monofunctional silane chemistry. This sorbent offers a unique selectivity and excellent recovery of anlytes, and is recommended as a general purpose SPE phase for both polar and non-polar analytes. Typical applications include extraction of drugs and their metabolites in serum, plasma or urine, desalting of peptides, isolation of trace organics in environmental water samples and organic acids in beverages. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT023590 - Sep-Pak C18 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk
Part Number: WAT023590
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry C18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

700003139 - Finger-Tight Reusable Fitting Kit

Part Number: 700003139

ACQUITY Reusable Finger-Tight Fitting Kit, used on Column Managers

700003139 - Finger-Tight Reusable Fitting Kit
Part Number: 700003139
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Products ACQUITY UPLC Column Heater/Cooler
ACQUITY UPLC Column Manager
Replacement Schedule As Needed

info

WAT034236 - Shodex SH-1011 Column, 7 µm, 8 x 300 mm

Part Number: WAT034236

Shodex® high performance polymeric columns for sugar analysis

WAT034236 - Shodex SH-1011 Column, 7 µm, 8 x 300 mm
Part Number: WAT034236
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Polymer
Solvent Water
Units in Package 1/pkg
pH Range 2 - 12

info

WAT271082 - Solvent Bottle Tray

Part Number: WAT271082

The Solvent Bottle Tray holds four 1-Liter bottles. The solvents should be placed above the gradient proportioning valve.

WAT271082 - Solvent Bottle Tray
Part Number: WAT271082
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module

info

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186001337

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186001337
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186002732 - SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002732

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002732 - SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002732
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186006029 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006029

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006029 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006029
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT270927 - 2690 GPV Assembly

Part Number: WAT270927

This spare part is a Waters Quality part

WAT270927 - 2690 GPV Assembly
Part Number: WAT270927
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Replacement Schedule As Needed

info

700008931 - Capillary Tube

Part Number: 700008931

Stainless Steel Capillary Tube

700008931 - Capillary Tube
Part Number: 700008931
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products SYNAPT G2 MS System
SYNAPT G2-S
Xevo Q-Tof Mass Spec
Replacement Schedule As Needed

info

201000233 - ACQUITY H QSM PERFORMANCE MAINTENANCE KIT

Part Number: 201000233

The Waters® Performance Maintenance Kit for the ACQUITY Quaternary Solvent Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: mixer, plungers, check valves seals and filters.

201000233 - ACQUITY H QSM PERFORMANCE MAINTENANCE KIT
Part Number: 201000233
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
Replacement Schedule Annually

info

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003581

The XBridge BEH130 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003581
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT094269 - Symmetry Shield RP 8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT094269

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP8 column significantly improves peak shape and resolution.

WAT094269 - Symmetry Shield RP 8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT094269
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

JJAN27198 - µBondapak Phenyl Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN27198

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

JJAN27198 - µBondapak Phenyl Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN27198
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.3
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

WAT200516 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pkg

Part Number: WAT200516

GHP has the broadest chemical compatibility and exhibits minimal protein binding

WAT200516 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pkg
Part Number: WAT200516
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 10 mL
Separation Mode Aqueous
Solvent/Sample Compatible GHP
Units in Package 100/pkg

info

430002235 - Tube, Anal Col Union to Col Out

Part Number: 430002235

This spare part is part of the Preparative Chromatography Rack for the 25X5 series of pumps.

430002235 - Tube, Anal Col Union to Col Out
Part Number: 430002235
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Pumps
Products 2545 Quaternary Gradient Pump
Replacement Schedule As Needed

info

700001493 - Cartridge Check Valve Assy, 4/pkg

Part Number: 700001493

The Check Valves are made of synthetic ruby and are contained in cartridges that are easy to replace.

700001493 - Cartridge Check Valve Assy, 4/pkg
Part Number: 700001493
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 2525 Binary Gradient Module
2535 Quaternary Gradient Module
2545 Binary Gradient Module
2545 Quaternary Gradient Pump
Replacement Schedule As Needed

info

430001194 - Sample Loop, 100µL

Part Number: 430001194

This spare part is a Waters Quality part

430001194 - Sample Loop, 100µL
Part Number: 430001194
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

JJAN11525 - Ultrahydrogel Column, 250, 6 µm, 7.8 mm X 300 mm, 200 - 30K, Water , 1/pkg

Part Number: JJAN11525

Ideal for the analysis of aqueous-soluble samples, such as; oligomers; oligosaccharides; polysaccharides; and cationic, anionic and amphoteric polymers.

JJAN11525 - Ultrahydrogel Column, 250, 6 µm, 7.8 mm X 300 mm, 200 - 30K, Water , 1/pkg
Part Number: JJAN11525
Brand: Ultrahydrogel
Ultrahydrogel®

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Parker-style
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 200 - 30K
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Pore Size 250
Solvent Water
USP Classification L25
Units in Package 1/pkg
pH Range 2 - 12

info

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001265

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001265
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003462

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003462
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001147

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001147
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

700005698 - 0.2µm Frit, 2.1mm, 12/pk

Part Number: 700005698

0.2µm Frit, 2.1mm, (12PK)

700005698 - 0.2µm Frit, 2.1mm, 12/pk
Part Number: 700005698
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Products ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
ACQUITY UPLC Sample Manager
ACQUITY UPLC Sample Organizer
Replacement Schedule As Needed

info

700001012 - PEEK Tubing Cutter

Part Number: 700001012

The PEEK Tubing Cutter makes clean, perpendicular cuts without collapsing thin capillary walls. Each one has guide holes to ensure precise cutting. This cutter is easy to use, durable and reliable.

700001012 - PEEK Tubing Cutter
Part Number: 700001012
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Capillary LC
Products ACQUITY UPLC PDA Detector
ACQUITY UPLC 2996 PDA Detector
ACQUITY UPLC Column Heater/Cooler
ACQUITY UPLC Column Manager
ACQUITY UPLC TUV Detector
CapLC 2487
CapLC 2996
CapLC System
CapLC XE System
Replacement Schedule No

info

700008869 - Welded Tube Assy, SS, .003 ID X 14.5 LG

Part Number: 700008869

ACQUITY Welded Tube Assy, SS, .003 ID X 14.5 long

700008869 - Welded Tube Assy, SS, .003 ID X 14.5 LG
Part Number: 700008869
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule As Needed

info

WAT084624 - Resolve C18 Radial-Pak Cartridge, 90Å, 5 µm, 8.0 mm X 100 mm, 1/pkg

Part Number: WAT084624

The non-encapped Resolve C18 column offers significantly different selectivity compared to similar HPLC packings like Nova-Pak and µBondapak. The change in chromatographic behavior is most commonly noticed with polar compounds, which are typically more retained.

WAT084624 - Resolve C18 Radial-Pak Cartridge, 90Å, 5 µm, 8.0 mm X 100 mm, 1/pkg
Part Number: WAT084624
Brand: Resolve

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10.2
Chemistry C18
Endcapped No
Format Radial-Pak Cartridge
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity High
Surface Area 200
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8