Product Listing:  700002332 - PerformancePLUS Check Valve Housing   to   WAT025561 - Restrictor

Sorted by Best Sellers
  Product    
info

700002332 - PerformancePLUS Check Valve Housing

Part Number: 700002332

This spare part is a Waters Quality part

700002332 - PerformancePLUS Check Valve Housing
Part Number: 700002332
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Separations Module
Products 2695 Separations Module
2795 Separations Module
Replacement Schedule As Needed

info

205000362 - Needle, Stainless Steel, 30µL

Part Number: 205000362

This spare part is a Waters Quality part

205000362 - Needle, Stainless Steel, 30µL
Part Number: 205000362
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
nanoACQUITY
Products ACQUITY UPLC Sample Manager
nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

205000401 - 2998 Semi-Preparative Flow Cell Kit

Part Number: 205000401

This spare part is a Waters Quality part

205000401 - 2998 Semi-Preparative Flow Cell Kit
Part Number: 205000401
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2998 Photodiode Array Detector
Replacement Schedule As Needed

info

205000439 - Flow Splitter, 30-100mL, 5000:1

Part Number: 205000439

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000439 - Flow Splitter, 30-100mL, 5000:1
Part Number: 205000439
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

700000290 - ApCI Probe Assembly

Part Number: 700000290

An atmospheric pressure chemical ionization(APCI) probe introduces the sample to the ion source. The original part number was 725000214. The part number has been changed to p/n 700000290.

700000290 - ApCI Probe Assembly
Part Number: 700000290
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule Annually

info

700000310 - Z Spray Sample Cone

Part Number: 700000310

This spare part is a Waters Quality part

700000310 - Z Spray Sample Cone
Part Number: 700000310
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products LCT Mass Spectrometer
Q-Tof II Mass Spectrometer
Q-Tof 1 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof micro Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
ZMD Mass Spectrometer
Replacement Schedule As Needed

info

700003170 - Collet and Comp. Screw Multi-Tool

Part Number: 700003170

ACQUITY Collet and Comppression Screw Multi-Tool, HFPT for a Column Manager

700003170 - Collet and Comp. Screw Multi-Tool
Part Number: 700003170
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY UPLC Column Heater/Cooler
ACQUITY UPLC Column Manager
Replacement Schedule As Needed

info

700003219 - Cap. Tube Assy., 40µm x 11.6in. long

Part Number: 700003219

Capillary Tube, 8-30 mL, 1000:1

700003219 - Cap. Tube Assy., 40µm x 11.6in. long
Part Number: 700003219
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

405005068 - One-Piece PEEK Knurled Fitting

Part Number: 405005068

The one-piece PEEK knurled fitting fits into the 10,000p?si nanoACQUITY system.

405005068 - One-Piece PEEK Knurled Fitting
Part Number: 405005068
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

430000922 - Low Dispersion Red Line

Part Number: 430000922

The Low Dispersion Red Line is a 20 inch long, 0.005 in ID PEEK red line with one piece fingertight fittings.

430000922 - Low Dispersion Red Line
Part Number: 430000922
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

5711366-S - O-RING SIZE BS006 PERLAST G60T (5PK)

Part Number: 5711366-S

This spare part is a Waters Quality part

5711366-S - O-RING SIZE BS006 PERLAST G60T (5PK)
Part Number: 5711366-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category O-rings
Product Category Mass Spectrometry
Products Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

700003521 - Seal Extraction Tool, .0787 Dia, BSM

Part Number: 700003521

ACQUITY Seal Extraction Tool, .0787 Dia, for I-Class BSM

700003521 - Seal Extraction Tool, .0787 Dia, BSM
Part Number: 700003521
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule As Needed

info

700001201 - Ion Block Heater Assembly

Part Number: 700001201

The Ion Block Heater Assembly is a heater cartridge that inserts into the stainless steel Ion Block.

700001201 - Ion Block Heater Assembly
Part Number: 700001201
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
LCT Premier
LCT Premier XE
Q-Tof Premier Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
ZQ Mass Spectrometer
Replacement Schedule No
sparepartsystemscategory LCMS

info

700001321 - Needle w/Housing and Needle Drive Motor

Part Number: 700001321

The Needle w/Housing and Needle Drive Motor is an improvement for the 2790 and standard for the 2795 Separations Module. The new needle with housing assembly includes a high tension stripper spring. The stronger spring allows the needle to shed polyethylene cap mats at temperatures as low as 4 degrees in the sample compartment. The higher force spring requires a higher torque motor to prevent stalling during initialization.

700001321 - Needle w/Housing and Needle Drive Motor
Part Number: 700001321
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule No

info

M960022DC1-S - Outer Source Assembly (GCT)

Part Number: M960022DC1-S

Outer Source Assembly (GCT)

M960022DC1-S - Outer Source Assembly (GCT)
Part Number: M960022DC1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products GCT Mass Spectrometer
Replacement Schedule As Needed

info

700003432 - Solvent Bottle, 15mL

Part Number: 700003432

Solvent Bottle for the Built In Fluidics System

700003432 - Solvent Bottle, 15mL
Part Number: 700003432
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products Single Quad Detector
Replacement Schedule As Needed

info

725000142 - Diverter Valve (standard)

Part Number: 725000142

The standard Diverter Valve (three-way valve) diverts the flow of solvent to a waste vessel as the dropper assembly moves between collection vessel positions.

725000142 - Diverter Valve (standard)
Part Number: 725000142
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Systems Components
Products Waters Fraction Collector II
Waters Fraction Collector III
Replacement Schedule As Needed

info

725000145 - Collection Rack, Eppendorf Tubes (120)

Part Number: 725000145

The optional Eppendorf tube rack replaces the standard tube rack. It allows collection of samples into 1.5mL Eppendorf tubes. The rack can hold 120 tubes.

725000145 - Collection Rack, Eppendorf Tubes (120)
Part Number: 725000145
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Systems Components
Products Waters Fraction Collector II
Waters Fraction Collector III
Replacement Schedule No

info

201000260 - ACQUITY I-Class BSM 18K Performance Maintenance Kit

Part Number: 201000260

The Waters® Performance Maintenance Kit for the ACQUITY I-Class Binary Solvent Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: plungers, check valves, seals and filters.

201000260 - ACQUITY I-Class BSM 18K Performance Maintenance Kit
Part Number: 201000260
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule Annually

info

PSL613607 - Solvent Inlet Filter 10µm 1/16in OD

Part Number: PSL613607

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

PSL613607 - Solvent Inlet Filter 10µm 1/16in OD
Part Number: PSL613607
Products > Chromatography Consumables & Columns > Accessories > Mobile Phase Filters

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

info

PSL613608 - Solvent Inlet Filter 10µm 1/8in OD

Part Number: PSL613608

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

PSL613608 - Solvent Inlet Filter 10µm 1/8in OD
Part Number: PSL613608
Products > Chromatography Consumables & Columns > Accessories > Mobile Phase Filters

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

info

PSL613609 - Solvent Inlet Filter 10µm 1/8in OD

Part Number: PSL613609

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

PSL613609 - Solvent Inlet Filter 10µm 1/8in OD
Part Number: PSL613609
Products > Chromatography Consumables & Columns > Accessories > Mobile Phase Filters

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

info

PSL618001 - SLIPFREE CONN/DOUBLE 6CM 0.005in i.d

Part Number: PSL618001

SLIPFREE™ Connectors guarantee a void-free connection because it pushes the tubing into the end-fitting for a perfect seal every time. They are fingertight to 10,000 PSI and never need wrenches. They automatically readjust to any style column endfittings and are compatible with with all commercially available columns we have tested. The stainless steel thread design offers great stability and no particle generation which could plug your system. They come in a wide variety of styles, lenghts and tubing i.d's to accomodate your particular application needs

PSL618001 - SLIPFREE CONN/DOUBLE 6CM 0.005in i.d
Part Number: PSL618001
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category SLIPFREE® Connectors
Hardware Type Fitting
Material of Construction Stainless Steel
Outside Diameter 1/16 in. (1.6 mm)

info

WAS081333 - Cuvette Holder Assembly

Part Number: WAS081333

The 2487/2489 detectors use a standard 10mm path length spectophotometric cell (quartz cuvette). The cuvette is inserted with the frosted sides facing up and down in the cuvette holder when placing it into the detector flow cell assembly. Fingerprints on the clear quartz sides interfere with the light path and compromise the integrity of the cuvette scanning operations. Since the cuvette scan is aquired by measuring the absorbances from a light path that includes both the flow cell and the cuvette, the solvent conditions in the flow cell should be identical for both the zero scan and the sample scan

WAS081333 - Cuvette Holder Assembly
Part Number: WAS081333
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector
2489 UV/Visible Detector

info

WAT037372 - Compression Screw, 1/8in. Tefzel, 5/Pkg

Part Number: WAT037372

Waters® tubing and fittings are carefully designed to provide leak-free connections, with low dead volume, and minimal band spreading. For best performance, these components must be clean, and designed to work together. The geometry of the ferrule and the conical port that it is used with must match, as well as the diameter of the tube and the fittings. A variety of materials, lengths and diameters are available to provide the flexibility you need when you set up and maintain your system.

WAT037372 - Compression Screw, 1/8in. Tefzel, 5/Pkg
Part Number: WAT037372
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Separations Module
Systems Components
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
ACQUITY UPLC Binary Solvent Manager
In-Line Degasser

info

WAT026810 - Tubing, 1/4 in. (6.4mm) O.D. X 0.19 in. (4.83 mm) I.D. X 10 ft (3.0 m) Length , PTFE

Part Number: WAT026810

Waters® tubing and fittings are carefully designed to provide leak-free connections, with low dead volume, and minimal band spreading. For best performance, these components must be clean, and designed to work together. The geometry of the ferrule and the conical port that it is used with must match, as well as the diameter of the tube and the fittings. A variety of materials, lengths and diameters are available to provide the flexibility you need when you set up and maintain your system.

WAT026810 - Tubing, 1/4 in. (6.4mm) O.D. X 0.19 in. (4.83 mm) I.D. X 10 ft (3.0 m) Length , PTFE
Part Number: WAT026810
Products > Chromatography Consumables & Columns > Accessories > Tubing
Hardware Type Tubing
Inside Diameter 0.19 in. (4.83 mm)
Length 10 ft (3.0 m)
Material of Construction PTFE
Outside Diameter 1/4 in. - (6.4 mm)

info

201000182 - NANOACQUITY SAMPLE MANAGER PERFORMANCE MAINTENANCE KIT

Part Number: 201000182

The Waters® Performance Maintenance Kit for the nanoACQUITY Sample Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annula basis. The Waters® Performance Maintenance Kit includes the following parts: air chassis filter, injector outlet tubes, needle, system outlet tubes, inject valve pod, wash syringe, injector syringe, sample loop and o-ring and vent valve cartridge. The nanoACQUITY Sample Manager PM kit fits into the 5000psi and 10,000psi nanoACQUITY systems.

201000182 - NANOACQUITY SAMPLE MANAGER PERFORMANCE MAINTENANCE KIT
Part Number: 201000182
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
nanoACQUITY UPLC Sample Manager
nanoACQUITY UPLC with 2D Technology
Replacement Schedule Annually

info

WAT025248 - Rheodyne 7725I Manual Injector

Part Number: WAT025248

The Rheodyne 7725I Manual Injector is a stand-alone injector that can be used on the 1525 Micro Binary HPLC Pump.

WAT025248 - Rheodyne 7725I Manual Injector
Part Number: WAT025248
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Pumps
Products 1525 Micro HPLC Pump
Rheodyne Injector
Replacement Schedule As Needed

info

WAT047491 - Flow Cell Replacement Kit (16ul)

Part Number: WAT047491

The 16µL Flow Cell Replacement kit contains the following items: (1) 16µL flow cell, (1) gasket (upper), and (1) gasket (lower), 4 wells.

WAT047491 - Flow Cell Replacement Kit (16ul)
Part Number: WAT047491
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 474 Scanning Fluorescence Detector

info

WAT025561 - Restrictor

Part Number: WAT025561

The Restrictor is a coil of 0.009in. tubing used with the high sensitivity noise filter to increase system backpressure when needed for certain applications.

WAT025561 - Restrictor
Part Number: WAT025561
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products 510 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump