Product Listing:  WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg   to   WAT084560 - Inline Precolumn Filter Kit

Sorted by Best Sellers
  Product    
info

WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT054225

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT054225
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186003837 - AccQ-Tag Ultra RP Column 130Å 1.7 µm, 2.1 mm 100 mm, 1/pkg

Part Number: 186003837

AccQ•Tag Ultra Chemistry is based on the versatile and proven AccQ•Tag Method— the leading chemistry solution for amino acid analysis and is specifically designed for accurate, high sensitivity UPLC analyses. AccQ•Tag Ultra utilizes the AccQ•Fluor™ Reagent to quickly and easily derivatize both primary and secondary amino acids in a single step to generate unparalleled quantitative results. The AccQ•Tag Ultra Chemistry Package is a comprehensive, fully-tested set of reagents, column and eluents including extensive documentation.

186003837 - AccQ-Tag Ultra RP Column 130Å 1.7 µm, 2.1 mm 100 mm, 1/pkg
Part Number: 186003837
Brand: AccQ-Tag Ultra

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Amino Acid
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Size (dp) 1.7 µm
Pore Size 130Å
Units in Package 1/pkg

info

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT

Part Number: WAT052586

The Waters® Performance Maintenance Kit for the 996/2996/ACQUITY 2996 PDA Detector contains all of the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts:a PerformancePLUS™ Long Life Lamp which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first, and an air filter.

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT
Part Number: WAT052586
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Capillary LC
Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector
ACQUITY UPLC 2996 PDA Detector
CapLC 2996
Replacement Schedule Annually

info

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates

Part Number: 186001831

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all 96-well plate products. These products include Oasis, Sep-Pak, µElution plates and Ostro to name a few. The manifold kit comes with the spacer which is required for use with the µElution plates. Collection plates, reservoir trays and sealing caps, vacuum pump can be purchased separately.

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates
Part Number: 186001831
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all 96-well plate products. These products include Oasis, Sep-Pak, µElution plates and Ostro to name a few. The manifold kit comes with the spacer which is required for use with the µElution plates. Collection plates, reservoir trays and sealing caps, vacuum pump can be purchased separately.

info

186003838 - AccQ-Tag Ultra Eluent A

Part Number: 186003838

AccQ•Tag Ultra Chemistry is based on the versatile and proven AccQ•Tag Method— the leading chemistry solution for amino acid analysis and is specifically designed for accurate, high sensitivity UPLC analyses. AccQ•Tag Ultra utilizes the AccQ•Fluor™ Reagent to quickly and easily derivatize both primary and secondary amino acids in a single step to generate unparalleled quantitative results. The AccQ•Tag Ultra Chemistry Package is a comprehensive, fully-tested set of reagents, column and eluents including extensive documentation.

186003838 - AccQ-Tag Ultra Eluent A
Part Number: 186003838
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Eluent
Shipping Formulation Liquid
Storage Room temp
System UPLC

info

WAT085140 - PIC Reagent B6

Part Number: WAT085140

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B6 is a 5 vials/pkg workable solution in UV range in mobile phase of 240+ nm.

WAT085140 - PIC Reagent B6
Part Number: WAT085140
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

700004206 - Capillary Tube

Part Number: 700004206

This spare part is a Waters Quality part

700004206 - Capillary Tube
Part Number: 700004206
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Xevo™ TQ MS
Replacement Schedule As Needed

info

JJAN27198 - µBondapak Phenyl Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN27198

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

JJAN27198 - µBondapak Phenyl Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN27198
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.3
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

700002456 - MS Leucine Enkephalin Kit

Part Number: 700002456

For use with Mass Spectrometers, 1 X 5mL 2ng/uL Leucine Enkephalin Solution in 50/50 Acetonitrile water amber flame sealed ampule 1 5mL 1% Acetic Acid Solution in 50/50 acetonitrile/water amber flame sealed ampule 1 empty 12mL screw thread amber vial with cap includes Certificate of Analysis

700002456 - MS Leucine Enkephalin Kit
Part Number: 700002456
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

430001923 - Tubing, HPLC Stainless Steel Inlet

Part Number: 430001923

HPLC Stainless Steel Inlet Tubing, .005ID x 24 long for ACQUITY 30cm Collumn Heater/Cooler

430001923 - Tubing, HPLC Stainless Steel Inlet
Part Number: 430001923
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category ACQUITY
Products ACQUITY UPLC 30cm Column Heater
Replacement Schedule As Needed

info

700005164 - Check Valve, Double Ball & Seat

Part Number: 700005164

ACQUITY H-Class QSM Double Ball & Seat Check Valve

700005164 - Check Valve, Double Ball & Seat
Part Number: 700005164
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category ACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
Replacement Schedule As Needed

info

186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003685

The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186003685
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002559

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002559
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT027059 - Porapak Q 50-80 mesh, 26 grams

Part Number: WAT027059

Porapak GC column packing materials simplify the analysis of a wide variety of complex compounds from atmospheric gases to organics.

WAT027059 - Porapak Q 50-80 mesh, 26 grams
Part Number: WAT027059
Products > Chromatography Consumables & Columns > Accessories > Gas Chromatography Packings
Category All Gas Packings

info

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045995

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045995
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT094226 - Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk

Part Number: WAT094226

The 3 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT094226 - Oasis HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 30 µm Particle Size, 100/pk
Part Number: WAT094226
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 60 mg
Units In Package 100/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

WAT082823 - Gradient Proportioning Valve

Part Number: WAT082823

The Gradient Proportioning Valve Assembly is a set of four 2-way valves, which features opening and closing rates and aperture sizes of an exceptionally tight tolerance. The four inlet valves are actuated by solenoids that have precise electrical characteristics to help reduce heat buildup and protect the system from outgassing. The gradient proportioning valve provides exact, reproducible mixing of up to four different solvents.

WAT082823 - Gradient Proportioning Valve
Part Number: WAT082823
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products PrepLC 4000
Replacement Schedule No

info

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red

Part Number: 6436005-S10

This spare part is a Waters Quality part

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red
Part Number: 6436005-S10
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products LCT Premier
Q-Tof micro Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001265

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001265
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

700003776 - ASSY, Frit, 0.2UM, 2.1MM, Pkg 3

Part Number: 700003776

Three 0.2 µm Inlet/Outlet Frits for 2.1 mm ID UPLC Columns

700003776 - ASSY, Frit, 0.2UM, 2.1MM, Pkg 3
Part Number: 700003776
Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Units in Package 3/pkg

info

725000417 - Vacuum Pump 110/115 V 60H

Part Number: 725000417

This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L

725000417 - Vacuum Pump 110/115 V 60H
Part Number: 725000417
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

This is an oil-less diaphragm pump with two gauges and regulators. The pump can be operated in vacuum or pressure modes. The pump comes plumbed with ¼” barbed fitting for use with vacuum hose. Pump: 1/8 Hp, ~25” Hg, 1.5 CFM Dimensions ~ 20 X 13 x 20 cm H x W x L

info

PSS831913 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS831913

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS831913 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS831913
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054955 - Sep-Pak C18 1 cc Vac Cartridge, 50 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk

Part Number: WAT054955

Sep-Pak C18 Vac cartridges contain a hydrophobic, reverse-phase, silica-based bonded phase that is used to adsorb analytes of even weak hydrophobicity from aqueous solutions. The Sep-Pak C18 sorbent is made using the most reproducible bonding technology available, utilizing monofunctional silane chemistry. This sorbent offers a unique selectivity and excellent recovery of anlytes, and is recommended as a general purpose SPE phase for both polar and non-polar analytes. Typical applications include extraction of drugs and their metabolites in serum, plasma or urine, desalting of peptides, isolation of trace organics in environmental water samples and organic acids in beverages. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT054955 - Sep-Pak C18 1 cc Vac Cartridge, 50 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk
Part Number: WAT054955
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry C18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 50 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

PSS831915 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS831915

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS831915 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS831915
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

205000399 - 2998 Analytical Flow Cell Kit

Part Number: 205000399

This spare part is a Waters Quality part

205000399 - 2998 Analytical Flow Cell Kit
Part Number: 205000399
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2998 Photodiode Array Detector
Replacement Schedule As Needed

info

700002333 - Check Valve, Ceramic, 1.75, 2/pkg

Part Number: 700002333

This spare part is a Waters Quality part

700002333 - Check Valve, Ceramic, 1.75, 2/pkg
Part Number: 700002333
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Separations Module
Products 1525 HPLC Pump
2695 Separations Module
2695D Dissolution Separations Module
2795 Separations Module
515 HPLC Pump
600 MultiSolvent Delivery System
Replacement Schedule As Needed

info

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003748

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003748
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186005380 - XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186005380

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005380 - XSelect CSH Phenyl-Hexyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186005380
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

6028622-S1 - Fused Silica Tube, 25-micron ID, 1m

Part Number: 6028622-S1

The Fused Silica Tube, 25µm ID is used for the Stream Select Module in the CapLC XE System. It is also used in the SYNAPT G2 HDMS and SYNAPT G2 MS. The capillary measures 375µm x25µm and is 1 m in length.

6028622-S1 - Fused Silica Tube, 25-micron ID, 1m
Part Number: 6028622-S1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products CapLC XE System
SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Replacement Schedule As Needed

info

WAT084560 - Inline Precolumn Filter Kit

Part Number: WAT084560

The In-Line Precolumn Filter is a 2µm filter that is placed before the column to help extend the life and preserve the chemistry of the column.

WAT084560 - Inline Precolumn Filter Kit
Part Number: WAT084560
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Systems
Products LC Module 1
Replacement Schedule As Needed