Product Listing:  M956232AD1-S - Nanoflow Probe Tip, thin wall, 10/pkg   to   WAT084198 - PIC B5 Low UV Reagent

Sorted by Best Sellers
  Product    
info

M956232AD1-S - Nanoflow Probe Tip, thin wall, 10/pkg

Part Number: M956232AD1-S

This spare part is a Waters Quality part

M956232AD1-S - Nanoflow Probe Tip, thin wall, 10/pkg
Part Number: M956232AD1-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products Q-Tof II Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Q-Tof micro Mass Spectrometer
Replacement Schedule As Needed

info

WAT200535 - Solvent Filter, PTFE, 47 mm, 0.2 µm, Non polar, 100/pkg

Part Number: WAT200535

This PTFE membrane is a good choice for use with aggresive organic solvents

WAT200535 - Solvent Filter, PTFE, 47 mm, 0.2 µm, Non polar, 100/pkg
Part Number: WAT200535
Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 47 mm
Format Solvent Filter
Pore Size 0.2 µm
Separation Mode Non polar
Solvent/Sample Compatible PTFE
Units in Package 100/pkg

info

WAT057924 - Cell Gasket, 2/Pkg

Part Number: WAT057924

The Cell Gasket is used in all the flow cells (Analytical, Analytical High Pressure (MS), Non-Metallic, Microbore, and Semi-Prep) for the PDA detectors.

WAT057924 - Cell Gasket, 2/Pkg
Part Number: WAT057924
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector
Replacement Schedule As Needed

info

186007574 - LC Multiresidue Pesticide Standards Kit

Part Number: 186007574

The LC Multiresidue Pesticide Standards Kit is a fit-for-purpose collection of 204 compounds designed to eliminate the need for sourcing individual pesticide standards and measure each one manually. It allows scientists to verify and validate the performance of pesticide screening methods faster. - Accurately detects and quantifies pesticides from a wide range of samples by LC-MS/MS - Contains 204 compounds of interest covering many pesticides listed by government agencies - Formulated & grouped into 10 vials for maximum long term stability - Quantitatively tested to confirm composition

186007574 - LC Multiresidue Pesticide Standards Kit
Part Number: 186007574
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Environment
Food
Packaging Kit
Product Type Kit
Shipping Formulation Liquid
Storage Frozen -20 C
System LC/MS

info

WAT058957 - 96-well Sample collection plate 1mL 50/pkg

Part Number: WAT058957

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

WAT058957 - 96-well Sample collection plate 1mL 50/pkg
Part Number: WAT058957
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format 96 Well Plates
Units in Package 50/pkg
Volume Capacity 1 mL

info

430001194 - Sample Loop, 100µL

Part Number: 430001194

This spare part is a Waters Quality part

430001194 - Sample Loop, 100µL
Part Number: 430001194
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

186001293 - Atlantis dc18 Column, 100Å, 5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186001293

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001293 - Atlantis dc18 Column, 100Å, 5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186001293
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT200534 - Solvent Filter, PTFE, 47 mm, 0.45 µm, Non polar, 100/pkg

Part Number: WAT200534

This PTFE membrane is a good choice for use with aggresive organic solvents

WAT200534 - Solvent Filter, PTFE, 47 mm, 0.45 µm, Non polar, 100/pkg
Part Number: WAT200534
Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 47 mm
Format Solvent Filter
Pore Size 0.45 µm
Separation Mode Non polar
Solvent/Sample Compatible PTFE
Units in Package 100/pkg

info

WAT034100 - Shodex KF-803 Column, 6 µm, 8 x 300 mm

Part Number: WAT034100

Ultrahigh efficiency GPC columns

WAT034100 - Shodex KF-803 Column, 6 µm, 8 x 300 mm
Part Number: WAT034100
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

700003055 - Sample Cone 0.5 Diam.

Part Number: 700003055

This spare part is a Waters Quality part

700003055 - Sample Cone 0.5 Diam.
Part Number: 700003055
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products 3100 Mass Detector
Single Quad Detector
Tandem Quadrupole Detector
Replacement Schedule As Needed

info

700003736 - Sample Cone Extraction Tool

Part Number: 700003736

This spare part is a Waters Quality part

700003736 - Sample Cone Extraction Tool
Part Number: 700003736
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category Mass Spectrometry
Products Single Quad Detector
Replacement Schedule As Needed

info

PSS845305 - Spherisorb SAX Column, 80Å, 5 µm, 4 mm X 250 mm, 1/pkg

Part Number: PSS845305

Spherisorb SAX columns contain a silica-based quaternary ammonium bonded sorbent. The column is listed as USP L14 and is used for anion-exchange separations.

PSS845305 - Spherisorb SAX Column, 80Å, 5 µm, 4 mm X 250 mm, 1/pkg
Part Number: PSS845305
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SAX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4 mm
Length (mm) 250 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L14
Units in Package 1/pkg
pH Range 2 - 8

info

WAS207069 - Assembly, Plunger

Part Number: WAS207069

Made from the highest quality sapphire, this plunger preserves the life span of the plunger seal. Precise roundness and smoothness tolerances minimize the wear of the plunger seal, while alignment of the plunger within its stainless steel holder ensures that the sapphire rides directly into the center of the plunger seal, reducing wear of both parts while safeguarding pump flow rates and system retention times.

WAS207069 - Assembly, Plunger
Part Number: WAS207069
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Plungers
Product Category Pumps
Products 1515 HPLC Pump
1525 HPLC Pump
515 HPLC Pump
Replacement Schedule Annually

info

700002143 - Column Clamp, Small

Part Number: 700002143

This spare part is a Waters Quality part

700002143 - Column Clamp, Small
Part Number: 700002143
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

WAT054245 - Symmetry C8 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT054245

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information.

WAT054245 - Symmetry C8 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT054245
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT025604 - Compression Screws and Ferrules, 5/Pkg

Part Number: WAT025604

Precisely manufactured inside and outside diameters ensure leak-free connections. Waters’® highest cleanliness standards and practices in the handling and packaging eliminate debris, which could damage valves and block columns.

WAT025604 - Compression Screws and Ferrules, 5/Pkg
Part Number: WAT025604
Products > Chromatography Consumables & Columns > Accessories > Fittings
Hardware Type Fitting
Material of Construction Stainless Steel
Outside Diameter 1/16 in. (1.6 mm)

info

6071220 - Ring Clamp, NW32/40

Part Number: 6071220

Ring Clamp for use with NW32 and NW40 fittings on vacuum lines and hoses, St. Stl.

6071220 - Ring Clamp, NW32/40
Part Number: 6071220
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
LCT Premier
LCT Premier XE
Q-Tof API US Mass Spectrometer
Q-Tof Premier Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
SYNAPT G2 HDMS System
SYNAPT G2 MS System
SPECVALUE134881948
Xevo G2 Q-Tof Mass Spec
Replacement Schedule As Needed

info

WAT033383 - 100µL Syringe, Rheodyne™

Part Number: WAT033383

The 100µL Rheodyne Syringe is a low pressure microsyringe, 2 inches long. 22 Gauge, and has a square end (90°) tip style.

WAT033383 - 100µL Syringe, Rheodyne™
Part Number: WAT033383
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Syringes
Product Category Injectors
Products Rheodyne Injector

info

176003701 - ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg with Glycoprotein Performance Test Standard

Part Number: 176003701

Waters Glycoprotein BEH Amide 300Å, 1.7 μm columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides.. Each batch of Glycoprotein BEH Amide 300Å 1.7 μm material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 186008010 that includes a mixture of ribonuclease A as well as ribonulease B glycoforms) to help ensure batch to batch consistency. This kit includes one Glycoprotein BEH Amide 300Å, 1.7 μm column and one vial of Waters Glycoprotein Performance Test Standard. The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.

176003701 - ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg with Glycoprotein Performance Test Standard
Part Number: 176003701
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
VanGuard Pre-column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Glycoprotein
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L68
Units in Package 1/pkg
pH Range 2 - 10

info

186004786 - XSelect HSS T3 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186004786

The HSS T3 column is a fully endcapped, low-coverage C18 bonded-phase column designed to retain extremely polar compounds by reversed-phase in high aqueous mobile phases.

186004786 - XSelect HSS T3 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186004786
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700011138 - Synthetic Vacuum Pump Oil

Part Number: 700011138

Synthetic Vacuum Pump Oil

700011138 - Synthetic Vacuum Pump Oil
Part Number: 700011138
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Vacuum fittings/components
Product Category Mass Spectrometry
Products SQ Detector 2
SYNAPT G2-Si
Single Quad Detector
Tandem Quadrupole Detector
Xevo G2-XS QTof
Xevo TQ-S MS
Xevo TQ-S micro
Xevo TQD
Replacement Schedule As Needed

info

186003353 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003353

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003353 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003353
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

WAT058951 - Oasis HLB 96-well Plate, 30 mg Sorbent per Well, 30 µm Particle Size, 1/pk

Part Number: WAT058951

The Oasis HLB 96-well plate contains the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. The unique balance of hydrophobicity and water-wettability of the Oasis HLB sorbent means you will never have to worry about poor results if individual wells of the 96-well plate dry out during the critical steps prior to sample loading. The Oasis HLB 96-well plate is designed to be used on many manifold configurations and most robotic liquid handling systems.

WAT058951 - Oasis HLB 96-well Plate, 30 mg Sorbent per Well, 30 µm Particle Size, 1/pk
Part Number: WAT058951
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry HLB
Format/Type 96-well Plate
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 30 mg
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

186000846C - LC GC Amber Glass 12 x 32mm Screw Neck Vial, with Cap and PTFE Septum, 2 mL Volume, 100/pkg

Part Number: 186000846C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000846C - LC GC Amber Glass 12 x 32mm Screw Neck Vial, with Cap and PTFE Septum, 2 mL Volume, 100/pkg
Part Number: 186000846C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2695
Waters 2795
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Amber Glass
Septa Type Cap and PTFE Septum
Units in Package 100/pkg
Volume Capacity 2 mL

info WAT097958 - 2.1x10mm Holder Kit for Cartridges and Guard Columns
Part Number: WAT097958
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

info

700004045 - Xevo TQ Standards Kit

Part Number: 700004045

Mass Spectrometry (XEVO TQ) standards kit for system assessment. 10 Components 1. 1X 25mL Tuning Solution X 10: Acetominophen (4-Acetamidophenol) 200pg/ul, Caffeine 200pg/ul, Sulfadimethoxine 100pg/ul, Verapamil, 50pg/ul, Chloramphenicol, 50pg/ul, 1 x 17-A-Hydroxyprogesterone, 5000pg/ul in 90% MeOH:10% Water Flame Sealed Ampule 2. 1 x 30mL Set up Solution QP: PPG1000 2.5 ng/ul, Triacetyl-B-cyclodextrin 5.0 ng/ul, Verapmil 100.0 pg/ul, Leucine Enkaphalin 1.0 ng/ul, Ammonium Acetate 0.31 mg/ml Acetonitrile/Water (1:1 V/V) Clear Nalgene Bottle 3. 1 x 30mL Calibration Solution: Sodium Iodide 2 ug/ul (+1%, -0%) Cesium Iodide 50 ng/ul (+1%, -0%) IPA/Water (1:1 V/V), Clear Nalgene Bottle 4. 1X 10mg Ion Sabre APCI Pos Sensitivity: 17-alphahydroxyprogesterone 10 mg solid in 4 ml Amber Screw Top Vial 5. 1X 50 mg ESI Negative Sensitivity: Chloramphenicol Solid 50mg 8 ml Amber Screw Top Vial 6. 1 X 5mg ESI Positive Sensitivity: Reserpine solid 5 mg in 4 ml Amber Screw Top Vial 7. 1 x 5mg Ion Sabre APCI Neg Sensitivity: Sulfadimethoxine Solid 5mg in 4 ml Amber Screw Top Vial 8. 1 x 0.1mg*Scanwave optimisation: [Glu1]-Fibrinopeptide B 0.1 mg ±0.01 mg in 4 mL Amber Screw top Vial 9. 1 x 3mL Mobile phase additiveAqueous Ammonia Specific Gravity - 0.88 to 0.89 (~30% w/w ammonia) Flame sealed ampule 10. 2 x 1mL Mobile phase additive: Formic Acid 98-100% Purity Flame sealed ampule 1 X 715001937 Solution Prep – Xevo TQ Document 1 Clear Nalgene Bottle 30ml Certificate of Analysis

700004045 - Xevo TQ Standards Kit
Part Number: 700004045
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

6061146-S - TIP SEAL KIT XDS35i / XDS100B

Part Number: 6061146-S

The Tip Seal Kit is part of the vacuum components on the Scroll Pump XDS35i.

6061146-S - TIP SEAL KIT XDS35i / XDS100B
Part Number: 6061146-S
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Vacuum fittings/components
Product Category Mass Spectrometry
Products LCT Premier XE
Q-Tof Premier Mass Spectrometer
Quattro Premier Mass Spectrometer
Synapt High Definition MS System™
Replacement Schedule As Needed

info

186005785 - Oasis WAX Online Prospekt-2/Symbiosis Cartridge, 30 µm Particle Size, 96/pk

Part Number: 186005785

The Oasis WAX cartridges for Symbiosis/Prospekt-2 systems are designed for rugged, reproducible, and ultra-fast on-line SPE in the Spark Holland Symbiosis and Prospekt-2 systems. Each cartridge contains 2.5 mg of Oasis WAX, a polymeric reversed-phase, weak anion exchange mixed-mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong acidic compounds. Each 800-series tray contains 96 cartridges and can be directly loaded into the Automatic Cartridge Exchange (ACE) or the ACE Feeder units of the Symbiosis/Prospekt-2 systems without the stainless steel tray holder/adaptor. For additional information on the Symbiosis and Prospekt-2 systems, go to http://www.spark.nl/

186005785 - Oasis WAX Online Prospekt-2/Symbiosis Cartridge, 30 µm Particle Size, 96/pk
Part Number: 186005785
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry WAX
Format/Type Online Prospekt-2/Symbiosis Cartridge
Ion Exch. Capacity 0.6 meq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Units In Package 96/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

186006363 - Reversed-Phase QC Reference Material

Part Number: 186006363

The Quality Control Reference Materials portfolio is a unique collection of standards and mixtures. These products allow the user to evaluate and benchmark their chromatography system before analysis of critical material. The products in the portfolio are all specially formulated based on the expertise of Waters scientist. The Reversed-Phase QC Reference Material is a significantly complex reference material mixture in that it contains compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. It can be used with a variety of column chemistries and dimensions, and system hardware. The Reversed-Phase QC Reference Material contains 7 compounds including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7. This standard mix should be used to confirm the benchmark performance of your analytical HPLC or UPLC system. This particular QC Reference Material is a specially formulated mix that includes a void marker, neutral, acidic and basic compounds. These compounds were vigorously tested and evaluated and chosen because they provide the following advantages: – Excellent benchmark – Good peak shape on UV – Acceptable for use on a variety of column

186006363 - Reversed-Phase QC Reference Material
Part Number: 186006363
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Column Chemistry C18 RP
Detector UV
Packaging 1/pkg
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT084198 - PIC B5 Low UV Reagent

Part Number: WAT084198

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B5 Low UV is a 5 vial/pkg of pentane sulfonic acid in a workable UV range in mobile phase 200+ nm.

WAT084198 - PIC B5 Low UV Reagent
Part Number: WAT084198
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV