Product Listing:  186003836 - AccQ-Tag Ultra Derivatization Kit   to   WAT062341 - Solvent Bottle Caps, 4L, 4/Pkg

Sorted by Best Sellers
  Product    
info

186003836 - AccQ-Tag Ultra Derivatization Kit

Part Number: 186003836

Amino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Derivitization Kit is a component of the UPLC® Amino Acid Analysis Application Solution. This kit is executed with UV detection and is enough for 250 anaylses.

186003836 - AccQ-Tag Ultra Derivatization Kit
Part Number: 186003836
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Modifiers
Shipping Formulation Liquid & Solid
Storage Room temp
System UPLC

info

205000730 - Active Preheater

Part Number: 205000730

ACQUITY Active Preheater (APH) SS 12.5 inches long

205000730 - Active Preheater
Part Number: 205000730
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY H-Class Column Heater-Active
Replacement Schedule As Needed

info

700002644 - Needle Assembly, PEEK

Part Number: 700002644

ACQUITY SM Needle Assembly, PEEK 30ul, standard

700002644 - Needle Assembly, PEEK
Part Number: 700002644
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: WAT066224

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: WAT066224
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT052874 - AccQ-Tag Method Manual

Part Number: WAT052874

Manual detailing Waters AccQ-Tag™ Precolumn derivatization method for amino acid analysis.

WAT052874 - AccQ-Tag Method Manual
Part Number: WAT052874
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Fittings (pp 29)

info

186000385C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg

Part Number: 186000385C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000385C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg
Part Number: 186000385C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1 mL

info

700005698 - 0.2µm Frit, 2.1mm, 12/pk

Part Number: 700005698

0.2µm Frit, 2.1mm, (12PK)

700005698 - 0.2µm Frit, 2.1mm, 12/pk
Part Number: 700005698
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Products ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
ACQUITY UPLC Sample Manager
ACQUITY UPLC Sample Organizer
Replacement Schedule As Needed

info

6416001-S1 - Tube, PTFE, 1/16-inch x 1m

Part Number: 6416001-S1

This PTFE Tube is part of the Gas Handling unit in the Q Tof Ultima Family of Mass Spectrometers.

6416001-S1 - Tube, PTFE, 1/16-inch x 1m
Part Number: 6416001-S1
Services & Support > Spare Parts > Spare Parts Catalog
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer

info

PSS830915 - Spherisorb Cyano (CN) Column, Normal Phase, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830915

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS830915 - Spherisorb Cyano (CN) Column, Normal Phase, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830915
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

WAS207006 - Assembly, Pump Head (w/check valves)

Part Number: WAS207006

An integral part of the Waters 1515 and 500 series pumps, the Pump Head Assembly is made from the highest quality stainless steel and comes complete with the inlet/outlet check valve and the Clear-100 Plunger Seal already installed. The Pump Head is rigorously tested for supperior performance.

WAS207006 - Assembly, Pump Head (w/check valves)
Part Number: WAS207006
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 1515 HPLC Pump
1525 HPLC Pump
515 HPLC Pump
Replacement Schedule As Needed

info 186008714 - PEEK One Piece Fingertight Fitting
Part Number: 186008714
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002033

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002033
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000442

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000442 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000442
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186002979

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186002979
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001147

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001147
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

WAT034207 - Pullulan Kit

Part Number: WAT034207

A unique collection of GFC standards for molecular weight determination. 8 Pullulan Standards for aqueous MW Testing at 200mg each of approximate molecular weight standards 5000, 10000, 20000, 50000, 100000, 200000, 400000, 800000

WAT034207 - Pullulan Kit
Part Number: WAT034207
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084038

The Carbohydrate Analysis Column features a covalently bonded amino packing that is ideally suited for the seperation of low molecular weight sugars such as mono,di-, and trisaccharides. This column typically uses a mobile phase consisting of 65-85% acetonitrile in water and a column temperature ranging from ambient to 35° C.

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084038
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Amino (NH2)
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

WAT094269 - Symmetry Shield RP 8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT094269

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP8 column significantly improves peak shape and resolution.

WAT094269 - Symmetry Shield RP 8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT094269
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

667003974 - Empower 3 Personal System Suitability

Part Number: 667003974

Calculates all System Suitability parameters described in the different Pharmacopoeia USP, EP and JP. Performs statistical calculations on results as repeatability and summarizes the information in graphical or tabular formats. Allows you to specify the control limits or warning limits to flag out of specifications (OOS) values. Develop custom reports with trend plots and statistics, summary graphics to highloght OOS values.

667003974 - Empower 3 Personal System Suitability
Part Number: 667003974
Products > Chromatography Consumables & Columns > Accessories
Product Compatibility Empower 3 all versions
Quantity 1

info

700002596 - UPLC Primary Check Valve Assy., 2/pkg

Part Number: 700002596

The UPLC Primary Check Valve fits into the ACQUITY UPLC ACQUITY I-Class and the nanoACQUITY UPLC. The original part number was 700002704 and it was changed to p/n 700002596. This is a spring-loaded check valve.

700002596 - UPLC Primary Check Valve Assy., 2/pkg
Part Number: 700002596
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category ACQUITY
nanoACQUITY
Products ACQUITY I-Class BSM
ACQUITY UPLC Binary Solvent Manager
High Pressure nanoACQUITY UPLC Binary Solvent Manager/Auxillary Solvent Manager
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
Replacement Schedule As Needed

info

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006938

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006938
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

PSS830615 - Spherisorb ODS1 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830615

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of ?6.2%.

PSS830615 - Spherisorb ODS1 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830615
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS1
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT082887 - RCM 8X10 CARTRIDGE HOLDER

Part Number: WAT082887
WAT082887 - RCM 8X10 CARTRIDGE HOLDER
Part Number: WAT082887
Products > Chromatography Consumables & Columns > Accessories > Radial Compression

info

WAT025531 - Solvent Reservoir Filter

Part Number: WAT025531

This 10-micron filter protects the system from particulate matter in the solvent bottle. All solvent filters are thoroughly cleaned at Waters® using a nitric acid wash to remove oils and other possible contaminants that can compromise results.

WAT025531 - Solvent Reservoir Filter
Part Number: WAT025531
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Filters
Product Category ACQUITY
Injectors
Pumps
Separations Module
Systems
Products 1515 HPLC Pump
1525 EF HPLC Pump
1525 HPLC Pump
1525 Micro HPLC Pump
2535 Quaternary Gradient Module
2545 Quaternary Gradient Pump
2555 Quaternary Gradient Module
2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2700 Sample Manager
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
ACQUITY UPLC Binary Solvent Manager
Alliance GPC/V 2000 Systems
LC Module 1
Replacement Schedule As Needed

info

PSS831815 - Spherisorb C8 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS831815

Spherisorb C8 columns are general purpose, silica-based reversed-phase columns that contain an Octyl ligand. These USP L7 columns are used when you require a less retentive sorbent compared to the Spheriorb ODS columns.

PSS831815 - Spherisorb C8 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS831815
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 5.8
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity Medium
Surface Area 220
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046910 - Holder kit for Cartridge and Guard Columns

Part Number: WAT046910

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

WAT046910 - Holder kit for Cartridge and Guard Columns
Part Number: WAT046910
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

info

WAS081140 - Analytical Flow Cell

Part Number: WAS081140

The Waters®TaperSlit™ Flow Cell design used in the 2487/2489 detectors renders the detector baseline insensitive to change in mobile phase refractive index. Refractive index changes occur during gradient separations or result from temperature or pump-induced pressure fluctuations.The TaperSlit™ flow cell has a taper to the internal bore of the flow cell. In the Waters® Analytical TaperSlit™ FlowCell, the combination of the lens and TaperSlit bore geometry prevents light from hitting the cell walls. The analytical cell has a 10mm path length and a cell volume of 10µL.

WAS081140 - Analytical Flow Cell
Part Number: WAS081140
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector
2489 UV/Visible Detector

info

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002350

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002350
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT270927 - 2690 GPV Assembly

Part Number: WAT270927

This spare part is a Waters Quality part

WAT270927 - 2690 GPV Assembly
Part Number: WAT270927
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Replacement Schedule As Needed

info

WAT062341 - Solvent Bottle Caps, 4L, 4/Pkg

Part Number: WAT062341

The four liter Solvent Bottle Cap is a polyethylene cap that prevents free exchange of atmospheric gasses with helium, but will not sustain an internal pressure build-up.The three-holed cap can accomodate a helium inlet line, helium exhaust line, and a solvent inlet line.

WAT062341 - Solvent Bottle Caps, 4L, 4/Pkg
Part Number: WAT062341
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Pumps
Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
626 LC System