Product Listing:  186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg   to   WAT094171DV - Deactivated 150uL glass insert with polyspring, 100pk

Sorted by Best Sellers
  Product    
info

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186002979

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186002979 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186002979
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084038

The Carbohydrate Analysis Column features a covalently bonded amino packing that is ideally suited for the seperation of low molecular weight sugars such as mono,di-, and trisaccharides. This column typically uses a mobile phase consisting of 65-85% acetonitrile in water and a column temperature ranging from ambient to 35° C.

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084038
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Amino (NH2)
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT

Part Number: WAT052586

The Waters® Performance Maintenance Kit for the 996/2996/ACQUITY 2996 PDA Detector contains all of the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts:a PerformancePLUS™ Long Life Lamp which is warranted for a lifetime of 2000 hours or 1 year, whichever comes first, and an air filter.

WAT052586 - PDA DETECTOR PERFORMANCE MAINTENANCE KIT
Part Number: WAT052586
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Capillary LC
Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector
ACQUITY UPLC 2996 PDA Detector
CapLC 2996
Replacement Schedule Annually

info

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001346

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001346
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT046980 - Symmetry C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046980

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046980 - Symmetry C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046980
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT052885 - AccQ-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT052885

Amino acid analysis is afundamental process in any protein research. Waters developed a new reagent specific for amino acid derivitization that provides enhanced quantitative accuracy and subpicomole detection for hydrolysate amino acids. We offer a system package consisting of an optimized instrument, prepackaged reagents and extensive documentation.

WAT052885 - AccQ-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT052885
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Amino Acid
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
Units in Package 1/pkg

info

PSS830915 - Spherisorb Cyano (CN) Column, Normal Phase, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830915

The Spherisorb CN chemistry is general purpose normal phase propyl cyano bonded ligand to a silica substrate. This column is conditioned and shipped with normal phase solvent.

PSS830915 - Spherisorb Cyano (CN) Column, Normal Phase, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830915
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 1/pkg
pH Range 2 - 8

info

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002350

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002350
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003953

Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003953
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186006938

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications.

186006938 - ACQUITY UPLC Peptide CSH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186006938
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

700000341 - ESI Stainless Steel Capillary Tube

Part Number: 700000341

This spare part is a Waters Quality part.

700000341 - ESI Stainless Steel Capillary Tube
Part Number: 700000341
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products 3100 Mass Detector
EMD 1000 Mass Spectrometer
LCT Mass Spectrometer
Q-Tof II Mass Spectrometer
Q-Tof 1 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Q-Tof micro Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Quattro micro Mass Spectrometer
Single Quad Detector
Tandem Quadrupole Detector
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed

info

WAT094171 - Low volume insert, 150 µL, w/plastic spring 100/pkg

Part Number: WAT094171

Vial inserts are a solution in applications where there is limited sample volume. Choose the appropriate volume insert for your sample volume and vial size.

WAT094171 - Low volume insert, 150 µL, w/plastic spring 100/pkg
Part Number: WAT094171
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Dimensions 12 x 32mm
Format Low Volume Inserts and Springs
GlassType Type 1 Class A
Units in Package 100/pkg

info

700002596 - UPLC Primary Check Valve Assy., 2/pkg

Part Number: 700002596

The UPLC Primary Check Valve fits into the ACQUITY UPLC ACQUITY I-Class and the nanoACQUITY UPLC. The original part number was 700002704 and it was changed to p/n 700002596. This is a spring-loaded check valve.

700002596 - UPLC Primary Check Valve Assy., 2/pkg
Part Number: 700002596
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category ACQUITY
nanoACQUITY
Products ACQUITY I-Class BSM
ACQUITY UPLC Binary Solvent Manager
High Pressure nanoACQUITY UPLC Binary Solvent Manager/Auxillary Solvent Manager
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
Replacement Schedule As Needed

info

PSS830615 - Spherisorb ODS1 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS830615

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of ?6.2%.

PSS830615 - Spherisorb ODS1 Column, 80Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS830615
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS1
Chemistry C18
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT084283 - PIC B8 Low UV Reagent

Part Number: WAT084283

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B8 low UV is a 5 vial/pkg of octane sulfonic acid in a workable UV range in mobile phase 200+ nm.

WAT084283 - PIC B8 Low UV Reagent
Part Number: WAT084283
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT062341 - Solvent Bottle Caps, 4L, 4/Pkg

Part Number: WAT062341

The four liter Solvent Bottle Cap is a polyethylene cap that prevents free exchange of atmospheric gasses with helium, but will not sustain an internal pressure build-up.The three-holed cap can accomodate a helium inlet line, helium exhaust line, and a solvent inlet line.

WAT062341 - Solvent Bottle Caps, 4L, 4/Pkg
Part Number: WAT062341
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Pumps
Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
626 LC System

info

700002644 - Needle Assembly, PEEK

Part Number: 700002644

ACQUITY SM Needle Assembly, PEEK 30ul, standard

700002644 - Needle Assembly, PEEK
Part Number: 700002644
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule As Needed

info

WAT023635 - Sep-Pak C18 Plus Long Cartridge, 820 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT023635

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns.

WAT023635 - Sep-Pak C18 Plus Long Cartridge, 820 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT023635
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry C18
Endcap End Capped
Format/Type Plus Long Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 820 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT052874 - AccQ-Tag Method Manual

Part Number: WAT052874

Manual detailing Waters AccQ-Tag™ Precolumn derivatization method for amino acid analysis.

WAT052874 - AccQ-Tag Method Manual
Part Number: WAT052874
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Fittings (pp 29)

info

WAT271019 - Seal Pack Rebuild Kit w/Needle

Part Number: WAT271019

The Seal Pack Rebuild Kit includes all of the parts necessary to replace seals in the seal body, including the high pressure seals. Replacement of these seals requires use of HPMV Tool Kit (WAT045427). The Rebuild Kit includes: one Teflon washer, one needlewash filter, one upper spacer, one lower spacer, one alignment tube, one wash tube seal, one needle, two high pressure seals, one compression screw, and one ferrule.

WAT271019 - Seal Pack Rebuild Kit w/Needle
Part Number: WAT271019
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module

info

700005698 - 0.2µm Frit, 2.1mm, 12/pk

Part Number: 700005698

0.2µm Frit, 2.1mm, (12PK)

700005698 - 0.2µm Frit, 2.1mm, 12/pk
Part Number: 700005698
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Products ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
ACQUITY UPLC Sample Manager
ACQUITY UPLC Sample Organizer
Replacement Schedule As Needed

info

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045995

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045995
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT270927 - 2690 GPV Assembly

Part Number: WAT270927

This spare part is a Waters Quality part.

WAT270927 - 2690 GPV Assembly
Part Number: WAT270927
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Replacement Schedule As Needed

info

201000107 - 2790/2795 PERFORMANCE MAINTENANCE KIT

Part Number: 201000107

The Waters® Performance Maintenance Kit for the 2790/2795 contains all the Waters Quality Parts® necessary to keep your 2790/2795 operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: one injection port seat, one injection port washer seal, one needle, one 500µL syringe, one filter insert assembly, two check valve cartidges, two plungers, two seals, four face seals, four seal wash tubes, seven solvent filters, one lithium battery, two seal wash face seals, two plunger wash seals, and one 2790 injector valve PM Kit.

201000107 - 2790/2795 PERFORMANCE MAINTENANCE KIT
Part Number: 201000107
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule Annually

info

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001265

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001265
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

186000385C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg

Part Number: 186000385C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

186000385C - LCGC Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg
Part Number: 186000385C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCGC Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1 mL

info

PSS831913 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS831913

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS831913 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS831913
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT022999 - Peek Tubing and Fitting Kit

Part Number: WAT022999

The PEEK Tubing and Fitting Kit includes the following: 12 PEEK ferrules, 6 compression screws 10-32 long, 6 compression screws 10-32 short, one PEEK tubing .005in. x 1/16in. x 60in., one PEEK tubing .010in. x 1/16in. x 60in., and 12 compression screw knobs

WAT022999 - Peek Tubing and Fitting Kit
Part Number: WAT022999
Products > Chromatography Consumables & Columns > Accessories > Tubing
Category PEEK Tubing
Hardware Type Tubing
Length 5 ft (1.5 m)
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

WAT054955 - Sep-Pak C18 1 cc Vac Cartridge, 50 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk

Part Number: WAT054955

Sep-Pak C18 Vac cartridges contain a hydrophobic, reverse-phase, silica-based bonded phase that is used to adsorb analytes of even weak hydrophobicity from aqueous solutions. The Sep-Pak C18 sorbent is made using the most reproducible bonding technology available, utilizing monofunctional silane chemistry. This sorbent offers a unique selectivity and excellent recovery of anlytes, and is recommended as a general purpose SPE phase for both polar and non-polar analytes. Typical applications include extraction of drugs and their metabolites in serum, plasma or urine, desalting of peptides, isolation of trace organics in environmental water samples and organic acids in beverages. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT054955 - Sep-Pak C18 1 cc Vac Cartridge, 50 mg Sorbent per Cartridge, 55-105 µm Particle Size, 100/pk
Part Number: WAT054955
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry C18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 50 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT094171DV - Deactivated 150uL glass insert with polyspring, 100pk

Part Number: WAT094171DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

WAT094171DV - Deactivated 150uL glass insert with polyspring, 100pk
Part Number: WAT094171DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Format Low Volume Inserts and Springs
GlassType Deactivated
Units in Package 100/pkg
Volume Capacity 150 µL