Product Listing:  WAT084040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg   to   700003169 - Reusable Gold HPFT Compression Screw

Sorted by Best Sellers
  Product    
info

WAT084040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084040

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

WAT084040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084040
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

430002242 - Tubing, Capillary w/ Frit 25µ x 18in.

Part Number: 430002242

This Capillary Tubing connects the BSM to the inject valve of the nanoACQUITY UPLC in the Direct Injection Configuration and the Single Pump Trapping Configuration. It also connects the Trap Valve with the MM union on the nanoACQUITY UPLC in the Dual Pump Trapping Configuration and the 2D Configuration. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page. This part number was originally p/n 430001564and then was changed to the new part number, p/n 430002242.

430002242 - Tubing, Capillary w/ Frit 25µ x 18in.
Part Number: 430002242
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
nanoACQUITY UPLC with 2D Technology
Replacement Schedule As Needed

info

700001229 - V3, Solenoid Valve Assembly

Part Number: 700001229

The Waste Valve, V3 is a two-way solenoid valve, similar, but not identical to the V3 solenoid valve used in the 717 Autosampler. The major difference in the 2690 waste valve is a change in the direction of flow through the valve to improve valve performance.

700001229 - V3, Solenoid Valve Assembly
Part Number: 700001229
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module

info

WAT073571 - Rheodyne, Prep Injector Valve

Part Number: WAT073571

This spare part is part of the Preparative Chromatography Rack for the 25X5 series of pumps.

WAT073571 - Rheodyne, Prep Injector Valve
Part Number: WAT073571
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category Injectors
Pumps
Products 2545 Quaternary Gradient Pump
FlexInject Manual Dual Injector Module
Rheodyne Injector
Replacement Schedule As Needed

info

186008056 - Oasis PRiME HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 100/pk

Part Number: 186008056

Oasis PRiME HLB sets the new performance standard for solid phase extraction cleanup in routine analysis. This sorbent will provide reversed-phase cleanup of acidic, basic and neutral compounds form complex sample matrices. Oasis PRiME HLB has been designed to simplify SPE with easy to follow protocols. It also produces cleaner samples by removing greater than 95% of common matrix interferences such as salts, proteins and phospholipids. Additionally, viscous samples can be processed with faster flows through the device and and less plugging. Based on the Oasis HLB sorbent technology, this water-wettable sorbent does not require conditioning and equilibration to provide excellent recoveries.

186008056 - Oasis PRiME HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 100/pk
Part Number: 186008056
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry PRiME HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Sorbent Weight 60 mg
Units In Package 100/pkg
Water Wettable Water Wettable

info

201000197 - ACQUITY I2V BSM PERFORMANCE MAINTENANCE KIT

Part Number: 201000197

The Waters® Performance Maintenance Kit for the ACQUITY I2V BSM contains all the Waters Quality Parts® necessary to keep your ACQUITY I2V BSM operating at peak performance. The kit also contains a detailed maintenance protocol, including calibration and diagnostic tools to ensure proper installation and function. The Waters® Performance Maintenance Kit for the ACQUITY I2V BSM includes the following parts: tubing (transducer to check vlv), air filter, plungers, flanged seals, wash seals, teflon o-ring, mixer assembly, check valves, solvent bottle filters, I2V cartridge, filter cartridge, and tubing (SSV to I2V). BSMs fitted with the new intelligent intake valve (I2V) began on June 14, 2007 and the cut over serial number is F07UPB573M.

201000197 - ACQUITY I2V BSM PERFORMANCE MAINTENANCE KIT
Part Number: 201000197
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY UPLC I2V Binary Solvent Manager
Replacement Schedule As Needed

info

186006846 - MS Cleaning Solution

Part Number: 186006846

For use in cleaning MS parts, 500mL MS cleaning solution

186006846 - MS Cleaning Solution
Part Number: 186006846
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm

Part Number: WAT030697

Ultrahigh efficiency GPC columns

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm
Part Number: WAT030697
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT010290 - Ion Exclusion Column, 7 µm, 7.8 x 300 mm

Part Number: WAT010290

IC-Pak Ion Exclusion columns are used for the analysis of weak acid anions such as fluoride and short chain organic acids from formate to butyrate.

WAT010290 - Ion Exclusion Column, 7 µm, 7.8 x 300 mm
Part Number: WAT010290
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Ion Exclusion
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode Ion-Exclusion
Particle Size (dp) 7 µm
Units in Package 1/pkg

info

PSL613321 - PEEK STARTER KIT (NUTS/FER/FIT)

Part Number: PSL613321

By Replacing stainless steel parts such as tubings, fittings, ferrules, mobile phase filters, in-line filters, etc. you are creating a biocompatible and metallic-free environment for your samples and mobile phase. The PEEK Starter Kit is a collection of items we believe is a good start for everybody working in the field of biochromatography. Each Kit is supplied in a sturdy plastic case. The Kit contains the following items: PEEK Fingertight One-Piece (6), PEEK Handtight Nut (4), PEEK Hex-Head Nut (4), PEEK Double Ferrules (20), PEEK Tubing 1/16 x 0.25mm (1 x 3m), PEEK Tubing 1/16 x 0.50mm (1 x 3m), PEEK Union (1), Elbow 90 Degrees (2), Elbow 180 Degrees (2), Guillotine Cutter (1), PAT™ Mobile Phase Filter - Last Drop (1)

PSL613321 - PEEK STARTER KIT (NUTS/FER/FIT)
Part Number: PSL613321
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category PEEK
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

WAT036975 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT036975

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT036975 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT036975
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Cartridge
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

PSS839548 - Spherisorb ODS2 Cartridge, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS839548

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS839548 - Spherisorb ODS2 Cartridge, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS839548
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT021902 - AP-1 Glass Column, 10x200 mm, 1/pkg

Part Number: WAT021902

Waters Advanced Purification (AP) glass columns are constructed of biocompatible glass and polymeric materials for use with silica, polymer, or soft gel packings.

WAT021902 - AP-1 Glass Column, 10x200 mm, 1/pkg
Part Number: WAT021902
Brand: Advanced Purification

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Protein
Endfitting Type Waters
Format AP Glass Column
ID 10 mm
Length (mm) 200 mm
Units in Package 1/pkg

info

WAT021817 - Ferrule, 1/16in. OD, PEEK

Part Number: WAT021817

Waters® tubing and fittings are carefully designed to provide leak-free connections, with low dead volume, and minimal band spreading. For best performance, these components must be clean, and designed to work together. The geometry of the ferrule and the conical port that it is used with must match, as well as the diameter of the tube and the fittings. A variety of materials, lengths and diameters are available to provide the flexibility you need when you set up and maintain your system.

WAT021817 - Ferrule, 1/16in. OD, PEEK
Part Number: WAT021817
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Detectors
Injectors
Pumps
Separations Module
Systems
Products 2690D Dissolution Separations Module
2790 Separations Module
626 LC System
996 Photodiode Array Detector
LC Module 1
Rheodyne Injector
Replacement Schedule As Needed

info

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates

Part Number: 186001831

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

186001831 - Extraction Plate Manifold for Oasis 96-Well Plates
Part Number: 186001831
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

The Waters manifold for 96-well plates is ideally suited for vacuum extraction of all Waters 96-well plate products including Oasis, Sep-Pak and µElution plates. The manifold kit comes with the Spacer which is required for use with the µElution plates. Collection plates, resovoir trays and sealing caps should be purchased seperately

info

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red

Part Number: 6436005-S10

This spare part is a Waters Quality part.

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red
Part Number: 6436005-S10
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products LCT Premier
Q-Tof micro Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

WAT027477 - µPorasil Silica Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT027477

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

WAT027477 - µPorasil Silica Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT027477
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

700005095 - GC Headspace Qualification Standards Kit

Part Number: 700005095

Gas Chromatograph standards kit for system assessment. 9 Ampules (20mL each of standard solutions containing): Solution 1 Qty 3 Blank (Acetone) Solution 2 Qty 6 0.1% o-Xylene, 0.02% 1,2,4-Tichlorobenzene All standards are in Acetone prepared v/v. Certificate of Analysis

700005095 - GC Headspace Qualification Standards Kit
Part Number: 700005095
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System GC

info

700001550 - Inline Filter Assembly

Part Number: 700001550

The In-Line Filter prevents particles from entering the system.

700001550 - Inline Filter Assembly
Part Number: 700001550
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Product Category Pumps
Products 2525 Binary Gradient Module
2545 Binary Gradient Module
Replacement Schedule As Needed

info

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg

Part Number: 186004498

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg
Part Number: 186004498
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

700006069 - Injection Valve Cartridge, Full Loop (18 KPSI)

Part Number: 700006069

ACQUITY I-Class FL Injection Valve Cartridge, 18 KPSI

700006069 - Injection Valve Cartridge, Full Loop (18 KPSI)
Part Number: 700006069
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Valves
Product Category ACQUITY
Products ACQUITY I-Class SM-FL
Replacement Schedule As Needed

info

700000435 - 6 Column Select Valve

Part Number: 700000435

The 6-Column Selection Valve is a 6-position, 14-port valve. You can select one of 6 columns at a time, and you can dedicate one of the 6 column positions to bypass or waste. The 6-column selection valve requires two additional column clips to be installed. Slots are provided in the front of the column heater to hold tubing in place.

700000435 - 6 Column Select Valve
Part Number: 700000435
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule No

info

186003034 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003034

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003034 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003034
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT026613 - GFP Plunger Seal (Black)

Part Number: WAT026613

Made from high-performance, glass-filled polymer, the GFP Plunger Seal is manufactured with an internal spring that is designed to provide the correct pressure on the plunger, increasing the life of both the sapphire plunger and the seal itself. Waters® has determined that the Clear-100™ Seal is best suited to most applications and is the seal most commonly used in Waters solvent delivery systems and Performance Maintenance Kits. However, the GFP seal may be a better choice in certain applications.

WAT026613 - GFP Plunger Seal (Black)
Part Number: WAT026613
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Pumps
Systems
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
LC Module 1

info

WAT085250 - Protein-Pak SEC Column, 60Å, 10 µm, 7.8 mm X 300 mm, 500 - 20K, 1/pkg

Part Number: WAT085250

10 µm diol-bonded gel filtration materials.

WAT085250 - Protein-Pak SEC Column, 60Å, 10 µm, 7.8 mm X 300 mm, 500 - 20K, 1/pkg
Part Number: WAT085250
Brand: Protein-Pak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Protein-Pak Columns
Application Peptide
Protein
Chemistry SEC
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 20K
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 60Å
USP Classification L20
Units in Package 1/pkg
pH Range 2 - 8

info

WAT271017 - Seal Wash Face Seal Kit,1/Pkg

Part Number: WAT271017

Integral to the 2690 and 2790 Separations Modules, these seals are part of the seal wash system and help ensure that plunger seal life is maximized.

WAT271017 - Seal Wash Face Seal Kit,1/Pkg
Part Number: WAT271017
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems

info

WAT034298 - Shodex KC-811 Column, 7 µm, 8 x 300 mm

Part Number: WAT034298

The Shodex KC-811 Column, which provides ion-exchange and reversed-phase chromatography modes, is packed with a sulfonated styrene-divinylbenzene copolymer. With high efficiency, this packing separates low-molecular-weight organic acids and water-soluble organics such as alcohols, aldehydes, and nitriles.

WAT034298 - Shodex KC-811 Column, 7 µm, 8 x 300 mm
Part Number: WAT034298
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Polymer
Units in Package 1/pkg
pH Range 2 - 12

info

WAT036805 - Sep-Pak tC18 Plus Light Cartridge, 145 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT036805

Silica-based bonded phase with strong hydrophobicity; trifunctional bonding chemistry gives it an increased hydrolytic stabilty; applications similar to C18.

WAT036805 - Sep-Pak tC18 Plus Light Cartridge, 145 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT036805
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry TC18
Endcap End Capped
Format/Type Plus Light Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 145 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186001293 - Atlantis dc18 Column, 100Å, 5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186001293

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001293 - Atlantis dc18 Column, 100Å, 5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186001293
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

700003169 - Reusable Gold HPFT Compression Screw

Part Number: 700003169

The Reusable Gold HPFT Compression Screws come as a package of 10 screws.

700003169 - Reusable Gold HPFT Compression Screw
Part Number: 700003169
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category ACQUITY
Products ACQUITY UPLC High Temperature Column Heater
ACQUITY UPLC Column Heater/Cooler
ACQUITY UPLC Column Manager
Replacement Schedule As Needed