Product Listing:  WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg   to   WAS290423 - Fuse, lamp power supply (2 Amp, micro (F1 and F2 on CPU)

Sorted by Best Sellers
  Product    
info

WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg

Part Number: WAT200500

This PTFE membrane is a good choice for use with aggresive organic solvents

WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg
Part Number: WAT200500
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 25 mm
Format Syringe Filter
Hold-up Volume < 100 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 100 mL
Separation Mode Non polar
Solvent/Sample Compatible PTFE
Units in Package 50/pkg

info

186003353 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003353

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003353 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003353
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

PSS831916 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 125 mm, 1/pkg

Part Number: PSS831916

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS831916 - Spherisorb ODS2 Column, 80Å, 5 µm, 4.6 mm X 125 mm, 1/pkg
Part Number: PSS831916
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 125 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT026805 - Tubing, 1/16 in. (1.6mm) O.D. X 0.040 in. (1.02 mm) I.D. X 10 ft (3.0 m) Length , Stainless Steel

Part Number: WAT026805

Waters® tubing and fittings are carefully designed to provide leak-free connections, with low dead volume, and minimal band spreading. For best performance, these components must be clean, and designed to work together. The geometry of the ferrule and the conical port that it is used with must match, as well as the diameter of the tube and the fittings. A variety of materials, lengths and diameters are available to provide the flexibility you need when you set up and maintain your system.

WAT026805 - Tubing, 1/16 in. (1.6mm) O.D. X 0.040 in. (1.02 mm) I.D. X 10 ft (3.0 m) Length , Stainless Steel
Part Number: WAT026805
Products > Chromatography Consumables & Columns > Accessories > Tubing
Hardware Type Tubing
Inside Diameter 0.040 in. (1.02 mm)
Length 10 ft (3.0 m)
Material of Construction Stainless Steel
Outside Diameter 1/16 in. (1.6 mm)

info

205000458 - High Flow Nebulizer

Part Number: 205000458

This part number 205000458 replaces the original part number 700002388.

205000458 - High Flow Nebulizer
Part Number: 205000458
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Detectors
Products 2420 Light Scattering Detector
2424 Evaporative Light Scattering Detector
Replacement Schedule As Needed

info

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003462

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003462
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186000438 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000438

XTerra RP18 columns are general purpose, hybrid-based, reversed-phase C18 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stabil?ity compared to a silica-based column.

186000438 - XTerra Shield RP18 Column, 125Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000438
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 12

info

6430203-S1 - Polypenco Tube, 1.01 x 0.15, 1m

Part Number: 6430203-S1

This is the insulation used on the nichrome wires

6430203-S1 - Polypenco Tube, 1.01 x 0.15, 1m
Part Number: 6430203-S1
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Mass Spectrometry
Products AutoSpec Premier Mass Spectrometer
Replacement Schedule As Needed

info WAT201549 - Insulin HMWP SEC Column, 125Å, 10 µm, 7.8 mm X 300 mm, 5K - 150K, 1/pkg
Part Number: WAT201549
Brand: Insulin HMWP

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations
Chemistry SEC
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode Gel Filtration (aqueous)
Molecular Weight Range 5K - 150K
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L20
Units in Package 1/pkg
pH Range 2 - 8

info

186005837 - 96-well Sample Collection Plate, 700uL Round well 25/pkg

Part Number: 186005837

Polypropylene 96-well plate with a well designed to have the lowest residual sample volume for ACQUITY UPLC Sample Managers. Meets all ANSI/SBS standards for robotic compatability.

186005837 - 96-well Sample Collection Plate, 700uL Round well 25/pkg
Part Number: 186005837
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Waters Acquity
Certified Not Certified
Format 96 Well Plates
Units in Package 25/pkg
Volume Capacity 700 µL

info

WAT020550 - Sep-Pak Accell Plus CM Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT020550

Sep-Pak Accell Plus CM Plus Short cartridges contain a silica-based, hydrophilic weak cation-exchanger with large pore size (300Å). The cartridges are designed for extraction of cationic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of molecules such as cationic proteins. Other applications include extraction of steriods, pesticides, and herbicides. These cartridges are provided in the short-body configurations for easily attachment to pumps and syringes. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.

WAT020550 - Sep-Pak Accell Plus CM Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT020550
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus CM
Format/Type Plus Short Cartridge
Ion Exch. Capacity 370 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT051518 - Gradient Mixer, Single Stage

Part Number: WAT051518

The Single Stage Gradient Mixer insures complete mixing of solvents in a gradient system. It is a flow-through device that responds rapidly to solvent composition changes due to its low volume.

WAT051518 - Gradient Mixer, Single Stage
Part Number: WAT051518
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Products 510 HPLC Pump
PrepLC 2000
PrepLC 4000
Replacement Schedule No

info

WAT042887 - UV Detector PQ Standard

Part Number: WAT042887

Kit contains standards appropriate for assessment of HPLC UV systems. 1 Ampule (10 mL standard solution contains): - 10.00 mg/L Acetophenone (+/- 5%) Purity > 99% - 10.00 mg/L Propiophenone (+/- 5%) Purity > 99% - 10.00 mg/L Butyrophenone (+/- 5%) Purity > 99% - 3.2 g/L Acetone (+/- 5%) Purity > 99.74% Solution in 60% HPLC Grade Methanol / 40% HPLC Grade Water, volume/volume.

WAT042887 - UV Detector PQ Standard
Part Number: WAT042887
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

186006518 - BEH200 SEC Protein Standard Mix

Part Number: 186006518

The BEH200 SEC Protein Standard Mix is a 5 component protein mixture (Thyroglobulin, IgG, BSA, Myoglobin, Uracil) used to benchmark ACQUITY UPLC BEH200 SEC, 1.7 µm Columns. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006518 - BEH200 SEC Protein Standard Mix
Part Number: 186006518
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

WAT045438 - High Pressure Motorized Valve Assembly

Part Number: WAT045438

The High Pressure Motorized Valve (HPMV) is a three-way valve that has two common ports and one controllable port. The HPMV is used in two of the three valve positions in the Fluids Pak: V1 (High Pressure Inject Valve) and V2 (High Pressure Syringe Valve). The basic valve is driven by a stepper motor.

WAT045438 - High Pressure Motorized Valve Assembly
Part Number: WAT045438
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Injectors
Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
LC Module 1
Replacement Schedule As Needed

info

186002448 - Sirocco Protein Precipitation Plate, 5/pkg

Part Number: 186002448

Waters, in collaboration with Pall Life Sciences, is pleased to introduce our new Protein Precipitation Plate — Sirocco™. The most technologically advanced protein precipitation plate on the market. The Sirocco™ Plate enables high-throughput “in-well” protein precipitation of biological samples without the fear of cloudy filtrates or clogged devices. This plate contains a unique filter system, a sealing cap mat and a patented valve technology designed specifically to allow “in-well” processing which prevents clogged wells, cross-talk or leaking during use. The Sirocco™ Protein Precipitation Plate provides optimum performance in faster processing time by reducing steps in ‘in-well’ sample processing and complete recovery of clean filtrate from smaller plasma sample volumes.

186002448 - Sirocco Protein Precipitation Plate, 5/pkg
Part Number: 186002448
Brand: Sirocco Protein Precipitation Plate

Products > Chromatography Consumables & Columns > Sample Preparation Products
Format/Type 96-well Plate
Mass Spec Compatibility Mass Spec Compatible
Mode All Precipitation Plates

info

405007627 - Plunger Removal Tool

Part Number: 405007627

ACQUITY BSM Plunger Removal Tool

405007627 - Plunger Removal Tool
Part Number: 405007627
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
ACQUITY I-Class BSM
Replacement Schedule As Needed

info

186004032 - MassPREP Micro Desalting Column

Part Number: 186004032

"The MassPREP on-line desalting column can effectively desalt proteins prior to LC-MS analyses. Because non-volatile salts (e.g., NaCl) cansuppress ionization of intact proteins leading to poor detection sensitivity, it is important to remove or significantly minimize the introduction ofthese compounds into the mass analyzer. The reversed-phase phenyl material contained in MassPREP on-line column successfully “traps” proteins,allowing the salts to be washed to waste prior to protein elution into the mass spectrometer. With an optimized LC-MS method, cycle times as lowas 4 minutes (for intact antibody) and 10 minutes (for reduced antibody) are achievable."

186004032 - MassPREP Micro Desalting Column
Part Number: 186004032
Brand: MassPrep

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Chemistry Phenyl
Endfitting Type Direct-Connect
Format Direct Connect Column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 1M
Particle Shape Spherical
Particle Size (dp) 20 µm
Particle Substrate Polymethacrylate
Pore Size 1000Å
Units in Package 1/pkg
pH Range 2 - 12

info

WAT094171DV - Deactivated 150uL glass insert with polyspring, 100pk

Part Number: WAT094171DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

WAT094171DV - Deactivated 150uL glass insert with polyspring, 100pk
Part Number: WAT094171DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Format Low Volume Inserts and Springs
GlassType Deactivated
Units in Package 100/pkg
Volume Capacity 150 µL

info

186000847DV - Deactivated Amber Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 186000847DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

186000847DV - Deactivated Amber Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 186000847DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified Not Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Deactivated Amber Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

186000116 - Oasis HLB 12 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 60 µm Particle Size, 20/pk

Part Number: 186000116

The 12 cc Oasis HLB cartridges contain the Oasis HLB sorbent, which is a universal polymeric reversed-phase sorbent that was developed for the extraction of a wide range of acidic, basic, and neutral compounds from various matrices using a simple, generic protocol. Since the Oasis HLB sorbent is water wettable, it maintains its capability for higher retention and excellent recoveries even if the sorbent runs dry, which means there is no need to take extraordinary steps to keep the sorbent beds from drying out during the critical steps prior to sample loading. The 60 µm particle size is recommended when working with viscous samples. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

186000116 - Oasis HLB 12 cc Vac Cartridge, 500 mg Sorbent per Cartridge, 60 µm Particle Size, 20/pk
Part Number: 186000116
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 12 cc
Chemistry HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 60 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 500 mg
Units In Package 20/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186007265

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186007265
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006156 - XSelect HSS T3 XP Column, 100Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006156

The trifunctional alkyl C18 bonded phase used for the HSS T3 sorbents is compatible with 100% aqueous mobile phase and provides ultra-low MS bleed, while promoting superior polar compound retention. HSS T3 HPLC columns are fully scalable and transferable to UPLC separations.

186006156 - XSelect HSS T3 XP Column, 100Å, 2.5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006156
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700003521 - Seal Extraction Tool, .0787 Dia, BSM

Part Number: 700003521

ACQUITY Seal Extraction Tool, .0787 Dia, for I-Class BSM

700003521 - Seal Extraction Tool, .0787 Dia, BSM
Part Number: 700003521
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule As Needed

info

700005472 - XEVO TQ-S Qualification Standards KIT

Part Number: 700005472

Mass Spectrometry (Xevo TQ-S) standards kit for system assessment. 11 Components: 1. 1 x 25mL Xevo TQ-S Tuning Solution X100: Acetominophen (4-Acetamidophenol) 2 ng/ul Caffeine, 2 ng/ul, Sulfadimethoxine, 1 ng/ul, Verapamil, 500 pg/ul, Chloramphenicol, 500 pg/ul, 17-A-Hydroxyprogesterone, 50 ng/ul, 90% MeOH:10% Water Flame Sealed Ampule 2. 1 x 30mL Set-up solution Xevo TQ-S: PPG1000 250 pg/ul, Triacetyl-B-cyclodextrin 500 pg/ul, Verapmil 10 pg/ul, Leucine Enkaphalin 100 pg/ul, Ammonium Acetate 0.31 mg/ml, Acetonitrile/Water (1:1 V/V) Clear Nalgene Bottle 3. 1 x 30mL Intellistart Resolution Solution X20: Sodium Iodide 2 µg/ul Cesium Iodide 50 ng/ul, Methyl Sulfate Sodium Salt 20 ng/µl, in IPA/Water (1:1 V/V) Clear Nalgene Bottle 4. 1 x 30mLCalibration Solution: Ortho-Phosphoric Acid 0.1% Acetonitrile/Water (1:1 V/V) Clear Nalgene Bottle 5. 1 x 10 mg Ion Sabre APCI Pos Sensitivity: 17-alphahydroxyprogesterone 10 mg Solid 4 ml Amber Screw Top Vial 6. 1 x 50 mg ESI Negative Sensitivity: Chloramphenicol Solid 50 mg 8 ml Amber Screw Top Vial 7. 1 x 5mg ESI Positive Sensitivity: Reserpine solid 5 mg 4 ml Amber Screw Top Vial 8. 1 x 5mg CarryOver Test QWB: Sulfadimethoxine Solid 5mg 4 ml Amber Screw Top Vial 9. 1 x 0.1mg* [Glu1]-Fibrinopeptide B ScanWave Optimization: 0.1 mg ±0.01 mg 4 mL Amber Screw top Vial 10. 1 x 3mL Mobile phase additive: Aqueous Ammonia Specific Gravity - 0.88 to 0.89 (~30% w/w ammonia) Flame sealed ampule 11. 2 x 1mLMobile phase Additive: Formic Acid 98-100% Purity Flame sealed ampule 1 X 715002796 Solution Prep – Xevo TQ-s Document Certificate of Analysis

700005472 - XEVO TQ-S Qualification Standards KIT
Part Number: 700005472
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

186003546 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 100 µm X 100 mm, 1/pkg

Part Number: 186003546

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186003546 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 100 µm X 100 mm, 1/pkg
Part Number: 186003546
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format nanoACQUITY Column 10K psi
ID 100 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186005401 - XSelect CSH Phenyl-Hexyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186005401

XSelect CSH Phenyl-Hexyl columns provide you with alternative analyte selectivity compared to traditional reversed-phase columns and are a valuable tool for method development. The trifunctionally bonded C6 phenyl-ligand is a robust, low bleed sorbent that selectively retains polyaromatic compounds through pi-pi interactions.

186005401 - XSelect CSH Phenyl-Hexyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186005401
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 11

info

186006348 - 20 Pesticide Mix Standard

Part Number: 186006348

10ug/mL of each: atrazin, atrazin-desethyl, cyanazin, sebuthylazin, simazin, terbuthylazin, hexazinone, chlortoluron, diuron, linuron, metobromuron, metoxuron, monolinuron, metolachlor, Methamidophos, Acephate, Methomyl, Dicrotophos, Buprofenzin, Fenpropimorph in Acetonitrile

186006348 - 20 Pesticide Mix Standard
Part Number: 186006348
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Environment
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System LC/MS

info

201000178 - MALDI TOF PERFORMANCE MAINTENANCE

Part Number: 201000178

The Waters® Performance Maintenance Kit for the MALDI micro MX ,MALDI LR, MALDI L, and MALDI R Mass Spectrometers contains all the Waters Quality Parts® necessary to keep yourinstrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kitincludes the following parts: Source component and vacuum pump components.

201000178 - MALDI TOF PERFORMANCE MAINTENANCE
Part Number: 201000178
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products MALDI LR Mass Spectometer
MALDI micro MX Mass Spectrometer
Replacement Schedule Annually

info

WAS290423 - Fuse, lamp power supply (2 Amp, micro (F1 and F2 on CPU)

Part Number: WAS290423

This spare part is a Waters Quality part

WAS290423 - Fuse, lamp power supply (2 Amp, micro (F1 and F2 on CPU)
Part Number: WAS290423
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Detectors
Products 2487 Dual Wavelength Absorbance Detector