Product Listing:  700005095 - GC Headspace Qualification Standards Kit   to   WAT034106 - Shodex KF-G Guard Column, 5 µm, 4.6 x 10 mm (THF)

Sorted by Best Sellers
  Product    
info

700005095 - GC Headspace Qualification Standards Kit

Part Number: 700005095

Gas Chromatograph standards kit for system assessment. 9 Ampules (20mL each of standard solutions containing): Solution 1 Qty 3 Blank (Acetone) Solution 2 Qty 6 0.1% o-Xylene, 0.02% 1,2,4-Tichlorobenzene All standards are in Acetone prepared v/v. Certificate of Analysis

700005095 - GC Headspace Qualification Standards Kit
Part Number: 700005095
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System GC

info

700005279 - Needle Assembly, 30 µL, FTN

Part Number: 700005279

ACQUITY FTN Needle Assembly, 30 uL, optional

700005279 - Needle Assembly, 30 µL, FTN
Part Number: 700005279
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Needles
Product Category ACQUITY
Products ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
Replacement Schedule As Needed

info

700001236 - Cone Gas Nozzle

Part Number: 700001236

This spare part is a Waters Quality part

700001236 - Cone Gas Nozzle
Part Number: 700001236
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
LCT Premier
LCT Premier XE
Quattro micro Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed
sparepartsystemscategory LCMS

info

186005270 - XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186005270

XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.

186005270 - XSelect CSH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186005270
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

700007286 - Fitting, 1/4-28 U PEEK Bulkhead Union

Part Number: 700007286

This spare part is a Waters Quality part

700007286 - Fitting, 1/4-28 U PEEK Bulkhead Union
Part Number: 700007286
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category SFC
Products Fluid Delivery Module (FDM-10)
Fluid Delivery Module (FDM-30)
Replacement Schedule As Needed

info

WAT025746 - Reference Valve Rebuild Kit

Part Number: WAT025746

This Reference Valve Rebuild Kit is a simple, cost-effective means for maintaining the reference valve that may have been added as an accessory to your Waters® pump. The kit provides all necessary parts and instructions to rebuild the reference valve and contains a diaphragm, actuator, and comprehensive instructions. The valve should be replaced or rebuilt every 12 months.

WAT025746 - Reference Valve Rebuild Kit
Part Number: WAT025746
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products 1515 HPLC Pump
1525 HPLC Pump
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
Replacement Schedule Annually

info WAT200685 - Long Needle Valve for Sep-Pak Device Vacuum Manifold, 20/pkg
Part Number: WAT200685
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

info

WAT085103 - PIC Reagent B7

Part Number: WAT085103

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B7 is a 5 vials/pkg workable solution in UV range in mobile phase of 240+ nm.

WAT085103 - PIC Reagent B7
Part Number: WAT085103
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

PSS833915 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS833915

Spherisorb SAX columns contain a silica-based quaternary ammonium bonded sorbent. The column is listed as USP L14 and is used for anion-exchange separations.

PSS833915 - Spherisorb SAX Column, 80Å, 10 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS833915
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry SAX
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Ion-Exchange
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L14
Units in Package 1/pkg
pH Range 2 - 8

info

186006107 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186006107

XSelect CSH C18 columns are general purpose C18 columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology enables superior peak shape and increased loading capacity for basic compounds. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006107 - XSelect CSH C18 XP Column, 130Å, 2.5 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186006107
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

WAT034236 - Shodex SH-1011 Column, 7 µm, 8 x 300 mm

Part Number: WAT034236

Shodex® high performance polymeric columns for sugar analysis

WAT034236 - Shodex SH-1011 Column, 7 µm, 8 x 300 mm
Part Number: WAT034236
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Particle Shape Spherical
Particle Size (dp) 7 µm
Particle Substrate Polymer
Solvent Water
Units in Package 1/pkg
pH Range 2 - 12

info

700003105 - SQD Set Up Solution

Part Number: 700003105

Mass Spectrometry (SQD) standards kit for system assessment. 1 x 10ml Set-up Solution QP: PPG 1000 2.5 ng/ul, Triacetyl-B-cyclodextrin 5.0 ng/ul, verapamil 100.0 pg/ul, ammonium acetate 0.31 mg/ml, Leucine Enkaphalin 1 ng/ul all in Acetonitrile/Water(1:1v/v)in brown Nalgene bottle Certificate of Analysis

700003105 - SQD Set Up Solution
Part Number: 700003105
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

WAT025604 - Compression Screws and Ferrules, 5/Pkg

Part Number: WAT025604

Precisely manufactured inside and outside diameters ensure leak-free connections. Waters’® highest cleanliness standards and practices in the handling and packaging eliminate debris, which could damage valves and block columns.

WAT025604 - Compression Screws and Ferrules, 5/Pkg
Part Number: WAT025604
Products > Chromatography Consumables & Columns > Accessories > Fittings
Hardware Type Fitting
Material of Construction Stainless Steel
Outside Diameter 1/16 in. (1.6 mm)

info

WAT200609 - Extraction Manifold, 20pos, 16x100mm tubes

Part Number: WAT200609

The manifold allows the user to process up to 20 samples concurrently using SPE devices. The manifold comes complete with glass chamber, 20-position cover equipped with vacuum gauge, control and release valve for monitoring and adjustment of vacuum level to control flow rate. Also included is the test tube rack, needle tips for directing flow into tube positions and luer plugs to close off positions when using less than 20 devices. Additional accessories are also available.

WAT200609 - Extraction Manifold, 20pos, 16x100mm tubes
Part Number: WAT200609
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

The manifold allows the user to process up to 20 samples concurrently using SPE devices. The manifold comes complete with glass chamber, 20-position cover equipped with vacuum gauge, control and release valve for monitoring and adjustment of vacuum level to control flow rate. Also included is the test tube rack, needle tips for directing flow into tube positions and luer plugs to close off positions when using less than 20 devices. Additional accessories are also available.

info

186007365 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186007365

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007365 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186007365
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT085501 - Ultrastyragel Column, 500Å, 5 µm, 7.8 mm X 300 mm, 100 - 10K, Toluene , 1/pkg

Part Number: WAT085501

High resolution GPC columns for low molecular weight applications.

WAT085501 - Ultrastyragel Column, 500Å, 5 µm, 7.8 mm X 300 mm, 100 - 10K, Toluene , 1/pkg
Part Number: WAT085501
Brand: Ultrastyragel
Ultrastyragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 100 - 10K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size 500Å
Solvent Toluene
Units in Package 1/pkg
pH Range 2 - 12

info

186008470 - ACQUITY UPLC M-Class BEH C4 Trap Column, 300Å, 5 µm, 300 µm X 50 mm, 1/pkg

Part Number: 186008470

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 300A pore, C4, 1.7um particles and each batch is specifically QC tested with a carefully selected protein standard mix to help ensure consistent performance and increased analytical column life.

186008470 - ACQUITY UPLC M-Class BEH C4 Trap Column, 300Å, 5 µm, 300 µm X 50 mm, 1/pkg
Part Number: 186008470
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 8
Chemistry C4
Endcapped No
Endfitting Type Parker-style
Format Trap Column
ID 300 µm
Length (mm) 50 mm
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
Silanol Activity Low
Surface Area 90
System Nano/Micro
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 10

info

JJAN11545 - Ultrahydrogel Column, Linear, 10 µm, 7.8 mm X 300 mm, 500 - 10M, Water , 1/pkg

Part Number: JJAN11545

Ideal for the analysis of aqueous-soluble samples, such as; oligomers; oligosaccharides; polysaccharides; and cationic, anionic and amphoteric polymers.

JJAN11545 - Ultrahydrogel Column, Linear, 10 µm, 7.8 mm X 300 mm, 500 - 10M, Water , 1/pkg
Part Number: JJAN11545
Brand: Ultrahydrogel
Ultrahydrogel®

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Endfitting Type Parker-style
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 10M
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Polymer
Pore Size Linear
Solvent Water
USP Classification L25
Units in Package 1/pkg
pH Range 2 - 12

info

WAT271018 - Seal Wash, Plunger Seal, Replacement Kit 2/Pkg

Part Number: WAT271018

Integral to the 2690 and 2790 Separations Modules, these seals are part of the seal wash system and help ensure that plunger seal life is maximized.

WAT271018 - Seal Wash, Plunger Seal, Replacement Kit 2/Pkg
Part Number: WAT271018
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems

info

WAT042881 - UV Detector Linearity Standards Kit

Part Number: WAT042881

Kit contains standards appropriate for assessment of UV. 7 Ampules (10 ml standard solutions contains): Ampule 1 100% Methanol Ampule 2 5.0 mg/L Propyl Paraben (+/-1%) Ampule 3 10.0 mg/L Propyl Paraben (+/-1%) Ampule 4 15.0 mg/L Propyl Paraben (+/-1%) Ampule 5 20.0 mg/L Propyl Paraben (+/-1%) Ampule 6 25.0 mg/L Propyl Paraben (+/-1%) Ampule 7 30.0 mg/L Propyl Paraben (+/-1%) Propyl Paraben Purity (? 99%). All standards are in 100% HPLC Grade Methanol. Certificate of Analysis

WAT042881 - UV Detector Linearity Standards Kit
Part Number: WAT042881
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT045424 - High Pressure Motorized Valve Rebuild Kit

Part Number: WAT045424

The high pressure valve rebuild kit contains all of the Waters Quality Parts® required to fully rebuild the valves of the Waters® 717/717 Plus Autosampler, 2690/2695 Separations Modules, 2690D/2695D Separations Modules and LC Module 1 system. The spool is crafted to precise hardness, smoothness, and alignment specifications. The high-pressure valve seals are made of proprietary materials and then packed in anti-static bags to further minimize the chance of particulate contamination. The rebuild kit contains a PTFE O-ring, seal, spool, high pressure seals, and comprehensive instructions.

WAT045424 - High Pressure Motorized Valve Rebuild Kit
Part Number: WAT045424
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
717/717 Plus Autosampler
LC Module 1
Replacement Schedule As Needed

info

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm

Part Number: WAT026770

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm
Part Number: WAT026770
Brand: IC-Pak HC

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT052840

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT052840
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT044380 - Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT044380

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT044380 - Nova-Pak C18 Guard Column, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT044380
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Guard Column
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186002632 - 384-well Sample Collection Plate, Square well, Polypropylene 250µL 50/pkg

Part Number: 186002632

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

186002632 - 384-well Sample Collection Plate, Square well, Polypropylene 250µL 50/pkg
Part Number: 186002632
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Waters Acquity
Certified Not Certified
Format 384 Well Plates
Units in Package 50/pkg
Volume Capacity 250 µL

info

205015017 - ACQUITY UPLC ID Cell PDA, Analytical

Part Number: 205015017

The ACQUITY UPLC Analytical Flowcell with Intelligent Chip Technology can be used in older detectors but the chip technology feature will not work with those older modules. Newer ACQUITY PDA models with serial number E10UPD761N or E10UPD761A or newer ACQUITY eLambda PDA Models with serial number F10UPD571N or F10UPD571A will have the chip technology feature working in the detectors. THis is the analytical flow cell for the ACQUITY PDA detector.

205015017 - ACQUITY UPLC ID Cell PDA, Analytical
Part Number: 205015017
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category ACQUITY
Products ACQUITY UPLC PDA Detector
ACQUITY UPLC eLAmbda PDA Detector
Replacement Schedule As Needed

info

186000113 - Symmetry Shield RP18 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000113

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000113 - Symmetry Shield RP18 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000113
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186004742

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004742 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186004742
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007377 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186007377

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007377 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186007377
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT034106 - Shodex KF-G Guard Column, 5 µm, 4.6 x 10 mm (THF)

Part Number: WAT034106

Ultrahigh efficiency GPC columns

WAT034106 - Shodex KF-G Guard Column, 5 µm, 4.6 x 10 mm (THF)
Part Number: WAT034106
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Guard Column
ID 4.6 mm
Length (mm) 10 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12