Product Listing:  700000344 - Graphite Ferrule, APcI, GVF-004   to   186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Sorted by Best Sellers
  Product    
info

700000344 - Graphite Ferrule, APcI, GVF-004

Part Number: 700000344

This spare part is a Waters Quality part.

700000344 - Graphite Ferrule, APcI, GVF-004
Part Number: 700000344
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Fittings
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
GCT Mass Spectrometer
GCT Premier Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Quattro micro GC Mass Spectrometer
Quattro micro Mass Spectrometer
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed

info

WAT036810 - Sep-Pak tC18 Plus Short Cartridge, 400 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT036810

Silica-based bonded phase with strong hydrophobicity; trifunctional bonding chemistry gives it an increased hydrolytic stabilty; applications similar to C18.

WAT036810 - Sep-Pak tC18 Plus Short Cartridge, 400 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT036810
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry TC18
Endcap End Capped
Format/Type Plus Short Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 37-55 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 400 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186002570 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186002570

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002570 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186002570
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003839 - AccQ-Tag Ultra Eluent B

Part Number: 186003839

mino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Eluent B is a component of the UPLC® Amino Acid Analysis Application Solution. Eluent B is a concentrate of 950 ml.

186003839 - AccQ-Tag Ultra Eluent B
Part Number: 186003839
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Eluent
Shipping Formulation Liquid
Storage Room temp
System UPLC

info 186008714 - PEEK One Piece Fingertight Fitting
Part Number: 186008714
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

WAT020525 - Sep-Pak Florisil Plus Long Cartridge, 910 mg Sorbent per Cartridge, 50-200 µm Particle Size, 50/pk

Part Number: WAT020525

Polar, highly active, weakly basic sorbent for adsorption of low to moderate polarity species from nonaqueous solutions.

WAT020525 - Sep-Pak Florisil Plus Long Cartridge, 910 mg Sorbent per Cartridge, 50-200 µm Particle Size, 50/pk
Part Number: WAT020525
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Florisil
Format/Type Plus Long Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Normal-phase
Particle Size 50-200 µm
Pore Size 60Å
Sorbent Substrate Florisil
Sorbent Weight 910 mg
Units In Package 50/pkg
Water Wettable Water Wettable

info

JJAN27324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN27324

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

JJAN27324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN27324
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.8
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700004749 - MS Reference Standard/ Horse Heart Myoglobin

Part Number: 700004749

Mass Spectrometry standard for system assessment. 2 X Horse Heart Myoglobin 2.5 mg ±0.125 mg 15 mL Clear Nalgene Bottle 1 X 715002043 Sample Preparation Document Certificate of Analysis

700004749 - MS Reference Standard/ Horse Heart Myoglobin
Part Number: 700004749
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

700003170 - Collet and Comp. Screw Multi-Tool

Part Number: 700003170

ACQUITY Collet and Comppression Screw Multi-Tool, HFPT for a Column Manager

700003170 - Collet and Comp. Screw Multi-Tool
Part Number: 700003170
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY UPLC Column Heater/Cooler
ACQUITY UPLC Column Manager
Replacement Schedule As Needed

info

186008471 - ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186008471

Based upon the highly successful BEH particle technology, the new patent pending ACQUITY UPLC BEH200 SEC column represents the first commer­cially available sub 2 ìm SEC chemistry. Fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 10,000 to 450,000 Daltons, the total system solution will routinely deliver fast, accurate aggregate determinations up to 10 times quicker that traditional HPLC-based SEC methods.

186008471 - ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186008471
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Protein
Chemistry SEC
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 200Å
QC Tested Protein
Silanol Activity Low
Surface Area 220
System UPLC/UHPLC
Technology BEH
USP Classification L33
Units in Package 1/pkg
pH Range 1 - 8

info

186002684 - SunFire C18 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186002684

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002684 - SunFire C18 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186002684
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

176003915 - CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176003915

CORTECS Shield RP18 columns provides complimentary selectivity to C8 and C18 stationary phases. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. The solid core particle morphology offers high efficiency and lower backpressures when compared to fully porouse particles of similar particle size.

176003915 - CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176003915
Brand: CORTECS

Products > Chromatography Consumables & Columns
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

WAT054200 - Symmetry C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: WAT054200

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054200 - Symmetry C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: WAT054200
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008056 - Oasis PRiME HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 100/pk

Part Number: 186008056

Oasis PRiME HLB sets the new performance standard for solid phase extraction cleanup in routine analysis. This sorbent will provide reversed-phase cleanup of acidic, basic and neutral compounds form complex sample matrices. Oasis PRiME HLB has been designed to simplify SPE with easy to follow protocols. It also produces cleaner samples by removing greater than 95% of common matrix interferences such as salts, proteins and phospholipids. Additionally, viscous samples can be processed with faster flows through the device and and less plugging. Based on the Oasis HLB sorbent technology, this water-wettable sorbent does not require conditioning and equilibration to provide excellent recoveries.

186008056 - Oasis PRiME HLB 3 cc Vac Cartridge, 60 mg Sorbent per Cartridge, 100/pk
Part Number: 186008056
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 3 cc
Chemistry PRiME HLB
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Sorbent Weight 60 mg
Units In Package 100/pkg
Water Wettable Water Wettable

info

WAT007355 - IC-Pak Anion Column, 10 µm, 4.6 x 50 mm

Part Number: WAT007355

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT007355 - IC-Pak Anion Column, 10 µm, 4.6 x 50 mm
Part Number: WAT007355
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

201000197 - ACQUITY I2V BSM PERFORMANCE MAINTENANCE KIT

Part Number: 201000197

The Waters® Performance Maintenance Kit for the ACQUITY I2V BSM contains all the Waters Quality Parts® necessary to keep your ACQUITY I2V BSM operating at peak performance. The kit also contains a detailed maintenance protocol, including calibration and diagnostic tools to ensure proper installation and function. The Waters® Performance Maintenance Kit for the ACQUITY I2V BSM includes the following parts: tubing (transducer to check vlv), air filter, plungers, flanged seals, wash seals, teflon o-ring, mixer assembly, check valves, solvent bottle filters, I2V cartridge, filter cartridge, and tubing (SSV to I2V). BSMs fitted with the new intelligent intake valve (I2V) began on June 14, 2007 and the cut over serial number is F07UPB573M.

201000197 - ACQUITY I2V BSM PERFORMANCE MAINTENANCE KIT
Part Number: 201000197
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY UPLC I2V Binary Solvent Manager
Replacement Schedule As Needed

info

186008660 - RapiFluor-MS Sialylated Glycan Performance Test Standard

Part Number: 186008660

The RapiFluor-MS Sialylated Glycan Performance Test Standard is intended for use as a proficiency or system suitability test standard, especially for for non-mAb customers to fill the chromatographic gap for highly sialyated glycans that 186007983 does not cover because it is based on an IgG. This standard contains approximately 30 μg of Fetuin from fetal bovine serum or approximately 400 pmoles of RapiFluor-MS labeled, released N-glycans.

186008660 - RapiFluor-MS Sialylated Glycan Performance Test Standard
Part Number: 186008660
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
System LC/MS

info

205000329 - Alliance Bottle Tray Kit

Part Number: 205000329

A larger capacity solvent tray is now used on all the Separations Modules as an option. This new tray relocates the detector directly above the column heater or column heater/cooler thus minimizing ambient temperature effects upon column to detector flow cell tubing. It also creates more space for larger solvent bottles. This change also enhances the routing of solvent and wash line tubings from the top of the system down into the module.

205000329 - Alliance Bottle Tray Kit
Part Number: 205000329
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
2795 Separations Module
2796 Bioseparations Module
Replacement Schedule As Needed

info

700004588 - LockSpray Ref Probe Assy

Part Number: 700004588

This spare part is a Waters Quality part.

700004588 - LockSpray Ref Probe Assy
Part Number: 700004588
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Replacement Schedule As Needed

info

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm

Part Number: WAT030697

Ultrahigh efficiency GPC columns

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm
Part Number: WAT030697
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

205000436 - Flow Splitter, 2.0-8.0mL, 100:1

Part Number: 205000436

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000436 - Flow Splitter, 2.0-8.0mL, 100:1
Part Number: 205000436
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

PSS839548 - Spherisorb ODS2 Cartridge, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: PSS839548

Spherisorb ODS2 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS2 packing features intermediate ligand density with a specified carbon load of 11.5%.

PSS839548 - Spherisorb ODS2 Cartridge, 80Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: PSS839548
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.5
Bonding Technology ODS2
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004741 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186004741

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives.

186004741 - ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186004741
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

430001630 - 2695 Sample Loop, 200µL

Part Number: 430001630

This spare part is a Waters Quality part.

430001630 - 2695 Sample Loop, 200µL
Part Number: 430001630
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Sample Loop
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

WAT022934 - Clear-100™ Plunger Seal

Part Number: WAT022934

Made from a proprietary material, the Clear-100™ Plunger Seals feature an internal spring that provides the correct pressure on the plunger, increasing the life of the sapphire and the seal itself. The Clear-100™ Seal features an exclusive ringed or ribbed design on the inside of the seal, which helps to maintain a snug fit and increases the seal’s durability. The Clear-100™ Seal is best suited to most applications for Waters® Solvent Delivery Systems. It is included in Performance Maintenance Kits.

WAT022934 - Clear-100™ Plunger Seal
Part Number: WAT022934
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Pumps
Systems
Products 1515 HPLC Pump
1525 HPLC Pump
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1
Replacement Schedule As Needed

info

WAT021817 - Ferrule, 1/16in. OD, PEEK

Part Number: WAT021817

Waters® tubing and fittings are carefully designed to provide leak-free connections, with low dead volume, and minimal band spreading. For best performance, these components must be clean, and designed to work together. The geometry of the ferrule and the conical port that it is used with must match, as well as the diameter of the tube and the fittings. A variety of materials, lengths and diameters are available to provide the flexibility you need when you set up and maintain your system.

WAT021817 - Ferrule, 1/16in. OD, PEEK
Part Number: WAT021817
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Detectors
Injectors
Pumps
Separations Module
Systems
Products 2690D Dissolution Separations Module
2790 Separations Module
626 LC System
996 Photodiode Array Detector
LC Module 1
Rheodyne Injector
Replacement Schedule As Needed

info

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red

Part Number: 6436005-S10

This spare part is a Waters Quality part.

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red
Part Number: 6436005-S10
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products LCT Premier
Q-Tof micro Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

WAT027477 - µPorasil Silica Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT027477

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

WAT027477 - µPorasil Silica Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT027477
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT023620 - Sep-Pak Accell Plus QMA 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 100/pk

Part Number: WAT023620

Sep-Pak Accell Plus QMA Vac cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These syringe-barrel-type cartridges are designed for use with vacuum manifolds and automated SPE instruments.

WAT023620 - Sep-Pak Accell Plus QMA 1 cc Vac Cartridge, 100 mg Sorbent per Cartridge, 37-55 µm Particle Size, 100/pk
Part Number: WAT023620
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 1 cc
Chemistry Accell Plus QMA
Format/Type Vac Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 100 mg
Units In Package 100/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000490

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000490 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000490
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12