Product Listing:  186006349 - 2-AB Glycan Performance Test Standard   to   WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm

Sorted by Price
  Product    
info

186006349 - 2-AB Glycan Performance Test Standard

Part Number: 186006349

The 2-AB Glycan Performance Test Standard is 2-AB labeled Human IgG and is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC BEH Glycan, 1.7 µm Columns. It comes in a Waters TruView vial as a lyophilized powder. There is 228 pmol total/vial. It is recommended that this standard be used on a regular basis for benchmarking column and system performance, similar to the QCRM product line.

186006349 - 2-AB Glycan Performance Test Standard
Part Number: 186006349
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Column Performances
Shipping Formulation Solid
Storage Frozen -20 C
System UPLC

info

600000668CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 600000668CV

All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.

600000668CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 600000668CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Beckman
Dynatech
Finnigan
Gilson
Hitachi
L.E.A.P.
LDC
Perkin-Elmer
Spark
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

600000669CV - LCMS Certified Amber Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg

Part Number: 600000669CV

All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.

600000669CV - LCMS Certified Amber Glass 12 x 32mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septa, 2 mL Volume, 100/pkg
Part Number: 600000669CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Agilent
Beckman
Dynatech
Finnigan
Fisons
Gilson
Hitachi
LDC
Perkin-Elmer
Spectra-Physics
Varian
Waters 2695
Waters 2795
Waters Acquity
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Vial
GlassType Amber Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 2 mL

info

600000671CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg

Part Number: 600000671CV

All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.

600000671CV - LCMS Certified Clear Glass 12 x 32mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septa, 1 mL Volume, 100/pkg
Part Number: 600000671CV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified LCMS Certified
Closure Type Screw Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Septa Type Cap and Preslit PTFE/Silicone Septa
Units in Package 100/pkg
Volume Capacity 1 mL

info

700003776 - ASSY, Frit, 0.2UM, 2.1MM, Pkg 3

Part Number: 700003776

Three 0.2 µm Inlet/Outlet Frits for 2.1 mm ID UPLC Columns

700003776 - ASSY, Frit, 0.2UM, 2.1MM, Pkg 3
Part Number: 700003776
Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Units in Package 3/pkg

info

WAT045905 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045905

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045905 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045905
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT045995

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT045995 - Symmetry C8 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT045995
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046970

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046970
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046980 - Symmetry C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046980

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046980 - Symmetry C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046980
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT054225

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054225 - Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT054225
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

WAT054275 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT054275

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

WAT054275 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT054275
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: WAT066224

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: WAT066224
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT200625 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: WAT200625

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT200625 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: WAT200625
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT200632 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT200632

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT200632 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT200632
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT200670 - Symmetry Shield RP 8 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT200670

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP8 column significantly improves peak shape and resolution.

WAT200670 - Symmetry Shield RP 8 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT200670
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186002551 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186002551

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002551 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186002551
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002553 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002553

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002553 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002553
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002554 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002554

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002554 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002554
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002559

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002559
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002560 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002560

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002560 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002560
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002684 - SunFire C18 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186002684

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002684 - SunFire C18 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186002684
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186002732 - SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002732

SunFire C8 columns are used for general purpose method development at low pH. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retentive compared to SunFire C18.

186002732 - SunFire C8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002732
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

WAT015209 - Sugar-Pak I Guard-Pak Insert, 10 µm, 10/pkg

Part Number: WAT015209

The Sugar-Pak I Guard-Pak Insert is used to extend and prolong the lifetime for the Sugar Pak I Column by removing chemical and particulate contaminants from the mobile phase stream.

WAT015209 - Sugar-Pak I Guard-Pak Insert, 10 µm, 10/pkg
Part Number: WAT015209
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Guard-Pak Insert
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 10/pkg

info

WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg

Part Number: WAT085188

The Sugar Pak I column separates monosaccharides and sugar alcohols via a strong cation-exchange mechanism. The resin is based on a sulfonated styrene-divinylbenzene polymer that provides pH stability by means of a calcium counterion.

WAT085188 - Sugar-Pak I Column, 10 µm, 6.5 mm X 300 mm, 1/pkg
Part Number: WAT085188
Brand: Sugar-Pak I

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column
Length (mm) 300 mm
Particle Size (dp) 10 µm
USP Classification L19
Units in Package 1/pkg

info

WAT044231 - Styragel Column, HR 0.5, 5 µm, 7.8 mm X 300 mm, 0 - 1K, THF , 1/pkg

Part Number: WAT044231

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044231 - Styragel Column, HR 0.5, 5 µm, 7.8 mm X 300 mm, 0 - 1K, THF , 1/pkg
Part Number: WAT044231
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 0 - 1K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 0.5
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044234 - Styragel Column, HR 1, 5 µm, 7.8 mm X 300 mm, 100 - 5K, THF , 1/pkg

Part Number: WAT044234

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044234 - Styragel Column, HR 1, 5 µm, 7.8 mm X 300 mm, 100 - 5K, THF , 1/pkg
Part Number: WAT044234
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 100 - 5K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 1
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT044237 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, THF , 1/pkg

Part Number: WAT044237

Styragel HR columns are high-resolution GPC columns packed with 5 µm particles and are ideal for characterizing samples in the low to mid molecular range where high resolution is critical.

WAT044237 - Styragel Column, HR 2, 5 µm, 7.8 mm X 300 mm, 500 - 20K, THF , 1/pkg
Part Number: WAT044237
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode SEC/GPC
Molecular Weight Range 500 - 20K
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Polymer
Pore Size HR 2
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

WAT054405 - Styragel Guard Column, 20 µm, 4.6 mm X 30 mm, THF , 1/pkg

Part Number: WAT054405

These Styragel Guard columns protect and increase the column lifetime of your Styragel 7.8 mm or 4.6 mm ID columns.

WAT054405 - Styragel Guard Column, 20 µm, 4.6 mm X 30 mm, THF , 1/pkg
Part Number: WAT054405
Brand: Styragel
Styragel® GPC

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Waters
Format Guard Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 20 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12

info

186002448 - Sirocco Protein Precipitation Plate, 5/pkg

Part Number: 186002448

Waters, in collaboration with Pall Life Sciences, is pleased to introduce our new Protein Precipitation Plate — Sirocco™. The most technologically advanced protein precipitation plate on the market. The Sirocco™ Plate enables high-throughput “in-well” protein precipitation of biological samples without the fear of cloudy filtrates or clogged devices. This plate contains a unique filter system, a sealing cap mat and a patented valve technology designed specifically to allow “in-well” processing which prevents clogged wells, cross-talk or leaking during use. The Sirocco™ Protein Precipitation Plate provides optimum performance in faster processing time by reducing steps in ‘in-well’ sample processing and complete recovery of clean filtrate from smaller plasma sample volumes.

186002448 - Sirocco Protein Precipitation Plate, 5/pkg
Part Number: 186002448
Brand: Sirocco Protein Precipitation Plate

Products > Chromatography Consumables & Columns > Sample Preparation Products
Format/Type 96-well Plate
Mass Spec Compatibility Mass Spec Compatible
Mode All Precipitation Plates

info

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm

Part Number: WAT030697

Ultrahigh efficiency GPC columns

WAT030697 - Shodex KF-801 Column, 6 µm, 8 x 300 mm
Part Number: WAT030697
Brand: Shodex
Shodex

Products > Chromatography Consumables & Columns > GPC & SEC Columns > GPC & SEC Columns
Endfitting Type Shodex
Format Column
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Polymer
Solvent THF
Units in Package 1/pkg
pH Range 2 - 12