Product Listing:  186003031 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg   to   WAT082887 - RCM 8X10 CARTRIDGE HOLDER

Sorted by Price
  Product    
info

186003031 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003031

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003031 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003031
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003033 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186003033

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003033 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186003033
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003034 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003034

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003034 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003034
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003042 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003042

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003042 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003042
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003045 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003045

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003045 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003045
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003055 - XBridge BEH C8 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003055

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed.

186003055 - XBridge BEH C8 Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003055
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186003064 - XBridge BEH C18 Sentry Guard Cartridge, 130Å, 5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186003064

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003064 - XBridge BEH C18 Sentry Guard Cartridge, 130Å, 5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186003064
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 12

info

186003116 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003116

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003116 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003116
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003117 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003117

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003117 - XBridge BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003117
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003335 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003335

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003335 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003335
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186003353 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003353

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003353 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003353
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186003607 - XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003607

The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003607 - XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186003607
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003613 - XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003613

The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003613 - XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003613
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003943 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003943

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003943 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003943
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003952 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003952

Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186003952 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186003952
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003953

Waters Oligonucleotide Separation Technology (OST) columns are based on the second generation of hybrid-silica BEH™ Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC® technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186003953 - XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003953
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg

Part Number: 186004021

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186004021 - XBridge BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 250 mm, 1/pkg
Part Number: 186004021
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format OBD Prep Column
ID 19 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT025054C - LCGC Certified Clear Glass 8 x 40 mm Snap Neck Vial, 1 mL Volume, 250/pkg

Part Number: WAT025054C

Waters Certified vials are tested for cleanliness by HPLC and held to tightest dimensional tolerances in the industry.

WAT025054C - LCGC Certified Clear Glass 8 x 40 mm Snap Neck Vial, 1 mL Volume, 250/pkg
Part Number: WAT025054C
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Hitachi
Waters 700 Series
Certified LCGC Certified
Closure Type Snap Neck
Dimensions 8 x 40 mm
Format Vial
GlassType Clear Glass
Units in Package 250/pkg
Volume Capacity 1 mL

info

WAT034207 - Pullulan Kit

Part Number: WAT034207

A unique collection of GFC standards for molecular weight determination. 8 Pullulan Standards for aqueous MW Testing at 200mg each of approximate molecular weight standards 5000, 10000, 20000, 50000, 100000, 200000, 400000, 800000

WAT034207 - Pullulan Kit
Part Number: WAT034207
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

WAT036889 - Soft Drink Analysis 4 Component Standard

Part Number: WAT036889

Soft Drink Analysis Standards ( 4 components) including Caffeine, Benzoate, Sobate, and Aspartame for use with NovaPak Column

WAT036889 - Soft Drink Analysis 4 Component Standard
Part Number: WAT036889
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Food
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT037525 - End Connector Kit

Part Number: WAT037525
WAT037525 - End Connector Kit
Part Number: WAT037525
Products > Chromatography Consumables & Columns > Accessories > Fittings

info

WAT042881 - UV Detector Linearity Standards Kit

Part Number: WAT042881

Kit contains standards appropriate for assessment of UV. 7 Ampules (10 ml standard solutions contains): Ampule 1 100% Methanol Ampule 2 5.0 mg/L Propyl Paraben (+/-1%) Ampule 3 10.0 mg/L Propyl Paraben (+/-1%) Ampule 4 15.0 mg/L Propyl Paraben (+/-1%) Ampule 5 20.0 mg/L Propyl Paraben (+/-1%) Ampule 6 25.0 mg/L Propyl Paraben (+/-1%) Ampule 7 30.0 mg/L Propyl Paraben (+/-1%) Propyl Paraben Purity (? 99%). All standards are in 100% HPLC Grade Methanol. Certificate of Analysis

WAT042881 - UV Detector Linearity Standards Kit
Part Number: WAT042881
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT042885 - UV Wavelength Accuracy (erbium perchlorate)

Part Number: WAT042885

Kit contains standards appropriate for assessment of UV Detector. 1X10mL standard solution contains: 10.0 gm/L Erbuim Perchlorate +/-5%) (Purity >=99.9%) in 100% HPLC Grade Water

WAT042885 - UV Wavelength Accuracy (erbium perchlorate)
Part Number: WAT042885
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT042887 - UV Detector PQ Standard

Part Number: WAT042887

Kit contains standards appropriate for assessment of HPLC UV systems. 1 Ampule (10 mL standard solution contains): - 10.00 mg/L Acetophenone (+/- 5%) Purity > 99% - 10.00 mg/L Propiophenone (+/- 5%) Purity > 99% - 10.00 mg/L Butyrophenone (+/- 5%) Purity > 99% - 3.2 g/L Acetone (+/- 5%) Purity > 99.74% Solution in 60% HPLC Grade Methanol / 40% HPLC Grade Water, volume/volume.

WAT042887 - UV Detector PQ Standard
Part Number: WAT042887
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector UV
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

WAT046910 - Holder kit for Cartridge and Guard Columns

Part Number: WAT046910

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

WAT046910 - Holder kit for Cartridge and Guard Columns
Part Number: WAT046910
Products > Chromatography Consumables & Columns > Accessories > Guard Hardware

The Sentry guard column holder is required for use with Sentry guard columns that have an I.D. of 3.0, 3.9, and 4.6 mm and a length of 20 mm. This kit also contains a column joining tube assembly which allows your holder to connect with the analytical column. The Sentry guard column holders can be used with any HPLC column regardless of the manufacturer. Replacement o-rings (WAT023401, 2/pk) can be purchased to ensure a leak-free connection.

info WAT054260 - Sep-Pak® Reservoir adaptor 12/box
Part Number: WAT054260
Products > Chromatography Consumables & Columns > Sample Preparation Products > SPE Accessories

info

WAT058957 - 96-well Sample collection plate 1mL 50/pkg

Part Number: WAT058957

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

WAT058957 - 96-well Sample collection plate 1mL 50/pkg
Part Number: WAT058957
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format 96 Well Plates
Units in Package 50/pkg
Volume Capacity 1 mL

info

WAT058958 - 96-well Sample collection plate 2mL 50/pkg

Part Number: WAT058958

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

WAT058958 - 96-well Sample collection plate 2mL 50/pkg
Part Number: WAT058958
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format 96 Well Plates
Units in Package 50/pkg
Volume Capacity 2 mL

info

WAT058959 - Sample collection plate sealing cap

Part Number: WAT058959

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

WAT058959 - Sample collection plate sealing cap
Part Number: WAT058959
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format Cap Mat
Septa Type PTFE
Units in Package 50/pkg

info

WAT082887 - RCM 8X10 CARTRIDGE HOLDER

Part Number: WAT082887
WAT082887 - RCM 8X10 CARTRIDGE HOLDER
Part Number: WAT082887
Products > Chromatography Consumables & Columns > Accessories > Radial Compression