Product Listing:  186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg   to   PSL613609 - Solvent Inlet Filter 10µm 1/8in OD

Sorted by Price
  Product    
info

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003964

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003964
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003965 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003965

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003965 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003965
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186004454 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004454

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004454 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004454
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg

Part Number: 186004498

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg
Part Number: 186004498
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004500

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004500
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004504

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004504
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186005465 - XBridge Protein BEH C4 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186005465

The reproducibility of a chromatographic column has a critical impact on the long-term reliability and robustness of an analytical method, and its reproducibility lies completely outside the user's control. With exceptional batch-to-batch and column-to-column reproducibility, Waters well-established particle and column manufacturing process control provides confidence in the long-term reliability of your analytical method. XBridge BEH300 C4, 3.5um Method Validation Kit includes three batches of chromatographic media [derived from different base particles] to judge the quality, reliability, and consistency of your chromatographic method. Each batch of selected XBridge BEH300 C18, 3.5um chemistry is specifically QC tested with a mixture of carefully selected protein standards to help ensure consistent performance.

186005465 - XBridge Protein BEH C4 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186005465
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 3/pkg
pH Range 1 - 10

info

186006029 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006029

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006029 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006029
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186006041 - XBridge BEH C8 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006041

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006041 - XBridge BEH C8 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006041
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186006091 - XBridge BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006091

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006091 - XBridge BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006091
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007264 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186007264

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007264 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186007264
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186007265

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186007265
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007270

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007270
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007273 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186007273

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007273 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186007273
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007313 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186007313

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007313 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186007313
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

186008212 - XBridge Oligonucleotide BEH C18 OBD Prep Column, 130Å, 2.5 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008212

Waters Oligonucleotide Separation Technology columns are based on the second generation of hybrid-silica BEH Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186008212 - XBridge Oligonucleotide BEH C18 OBD Prep Column, 130Å, 2.5 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008212
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186001260 - Waters PAH C18 Column, 120Å, 3 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186001260

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001260 - Waters PAH C18 Column, 120Å, 3 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186001260
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001265

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001265
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info JJAN21018 - Puresil C18, 4.6x250mm column
Part Number: JJAN21018
Products > Chromatography Consumables & Columns > Accessories

info JJAN40007 - PTFE Septa for Wide Mouth Vial, 2mL, 1000/pk
Part Number: JJAN40007
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers

info

PSL404219 - Aluminum, Crimp Cap and PTFE/silicone Septum, 100/pkg

Part Number: PSL404219

For more information on the complete line of Waters vials, please download Waters latest brochure on vials and accessories.

PSL404219 - Aluminum, Crimp Cap and PTFE/silicone Septum, 100/pkg
Part Number: PSL404219
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified Not Certified
Closure Type Crimp
Color Aluminum
Format Cap and PTFE/silicone Septum
Units in Package 100/pkg

info

PSL404231 - Aluminum, Crimp Cap and PTFE/silicone/PTFE Septum, 100/pkg

Part Number: PSL404231

For more information on the complete line of Waters vials, please download Waters latest brochure on vials and accessories.

PSL404231 - Aluminum, Crimp Cap and PTFE/silicone/PTFE Septum, 100/pkg
Part Number: PSL404231
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Certified Not Certified
Closure Type Crimp
Color Aluminum
Format Cap and PTFE/silicone/PTFE Septum
Units in Package 100/pkg

info PSL613301 - Male Nut PEEK, Knurled Head
Part Number: PSL613301
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

PSL613302 - PEEK Double Tight Ferrule

Part Number: PSL613302
PSL613302 - PEEK Double Tight Ferrule
Part Number: PSL613302
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info PSL613312 - PEEK Union with 2 PEEK Fingertight Nuts and Double Ferrules 1/16in.
Part Number: PSL613312
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info PSL613316 - PEEK Two piece Fingertight Fittings, 1/16in, 10-32 Thread 0.125in/0.235in
Part Number: PSL613316
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

PSL613321 - PEEK STARTER KIT (NUTS/FER/FIT)

Part Number: PSL613321

By Replacing stainless steel parts such as tubings, fittings, ferrules, mobile phase filters, in-line filters, etc. you are creating a biocompatible and metallic-free environment for your samples and mobile phase. The PEEK Starter Kit is a collection of items we believe is a good start for everybody working in the field of biochromatography. Each Kit is supplied in a sturdy plastic case. The Kit contains the following items: PEEK Fingertight One-Piece (6), PEEK Handtight Nut (4), PEEK Hex-Head Nut (4), PEEK Double Ferrules (20), PEEK Tubing 1/16 x 0.25mm (1 x 3m), PEEK Tubing 1/16 x 0.50mm (1 x 3m), PEEK Union (1), Elbow 90 Degrees (2), Elbow 180 Degrees (2), Guillotine Cutter (1), PAT™ Mobile Phase Filter - Last Drop (1)

PSL613321 - PEEK STARTER KIT (NUTS/FER/FIT)
Part Number: PSL613321
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category PEEK
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info PSL613324 - PEEK Fittings with Double Ferrules, 1/16in, 10-32 Thread 1/4in/0.605
Part Number: PSL613324
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category Compression Screws and Ferrules
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

PSL613570 - Solvent Inlet Filter 10µm 1/16in OD

Part Number: PSL613570

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

PSL613570 - Solvent Inlet Filter 10µm 1/16in OD
Part Number: PSL613570
Products > Chromatography Consumables & Columns > Accessories > Mobile Phase Filters

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

info

PSL613609 - Solvent Inlet Filter 10µm 1/8in OD

Part Number: PSL613609

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.

PSL613609 - Solvent Inlet Filter 10µm 1/8in OD
Part Number: PSL613609
Products > Chromatography Consumables & Columns > Accessories > Mobile Phase Filters

It is good practice to always filter your solvents to prevent system damage. Filters should be changed periodically depending on usage and mobile phase.