Product Listing:  186005351 - ACQUITY UPLC CSH Fluoro Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg   to   186003708 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 19 mm X 150 mm, 1/pkg

Sorted by Brand
  Product    
info

186005351 - ACQUITY UPLC CSH Fluoro Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186005351

Designed to maximize selectivity differences, the ACQUITY CSH Fluoro-Phenyl column provides maximum method development freedom, especially when using low pH mobile phases. The non-encapped sorbent provides you with enhanced retention of acidic compounds.

186005351 - ACQUITY UPLC CSH Fluoro Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186005351
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 10
Bonding Technology Fluoro Phenyl
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L43
Units in Package 1/pkg
pH Range 1 - 8

info

186004850 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pkg

Part Number: 186004850

ACQUITY BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. Based on BEH technology the ACQUITY Amide columns offer a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 12 to enable the separation of polar analytes that span a wide range of polarity, structural moiety and pKa.

186004850 - ACQUITY UPLC BEH Amide Column, 130Å, 1.7 µm, 1 mm X 150 mm, 1/pkg
Part Number: 186004850
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Chemistry Amide
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004739

The ACQUITY UPLC BEH Glycan Separation Technology Column, also known as BEH Glycan, is optimized for use with ACQUITY UPLC systems with fluorescence detection (FLR), separating the released glycans of biopharmaceuticals as their 2-aminobenzamide (2-AB) derivatives. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186004739 - ACQUITY UPLC Glycan BEH Amide VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186004739
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
Units in Package 3/pkg
pH Range 2 - 11

info

186004681 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186004681

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations.

186004681 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186004681
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003980 - ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003980

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003980 - ACQUITY UPLC BEH HILIC VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003980
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity High
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 3/pkg
pH Range 1 - 9

info

186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003685

The ACQUITY BEH300 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003685 - ACQUITY UPLC Peptide BEH C18 Column, 300Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186003685
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003544 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pkg

Part Number: 186003544

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186003544 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pkg
Part Number: 186003544
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format nanoACQUITY Column 10K psi
ID 75 µm
Length (mm) 200 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186003535 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pkg

Part Number: 186003535

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations.

186003535 - ACQUITY UPLC HSS T3 Column, 100Å, 1.8 µm, 1 mm X 50 mm, 1/pkg
Part Number: 186003535
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

176003906 - ACQUITY UPLC Protein BEH SEC Column 125Å, 1.7 µm, 4.6 x 150 mm and BEH125 SEC Protein Standard Mix

Part Number: 176003906

Based upon the highly successful BEH particle technology, the new patent pending ACQUITY UPLC BEH125 SEC column represents the first commer­cially available sub 2 ìm SEC chemistry. Fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 1000 to 80,000 Daltons, the total system solution will routinely deliver fast, accurate aggregate determinations up to 10 times quicker that traditional HPLC-based SEC methods.

176003906 - ACQUITY UPLC Protein BEH SEC Column 125Å, 1.7 µm, 4.6 x 150 mm and BEH125 SEC Protein Standard Mix
Part Number: 176003906
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Protein
Chemistry SEC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Molecular Weight Range 1K - 80K
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 125Å
QC Tested Protein
Silanol Activity Low
Surface Area 220
System UPLC/UHPLC
Technology BEH
USP Classification L33
Units in Package 1/pkg
pH Range 1 - 8

info

176003905 - ACQUITY UPLC Protein BEH SEC Column 200Å, 1.7 µm, 4.6 x 300 mm and BEH200 SEC Protein Standard Mix

Part Number: 176003905

Based upon the highly successful BEH particle technology, the new patent pending ACQUITY UPLC BEH200 SEC column represents the first commer­cially available sub 2 ìm SEC chemistry. Fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 10,000 to 450,000 Daltons, the total system solution will routinely deliver fast, accurate aggregate determinations up to 10 times quicker that traditional HPLC-based SEC methods.

176003905 - ACQUITY UPLC Protein BEH SEC Column 200Å, 1.7 µm, 4.6 x 300 mm and BEH200 SEC Protein Standard Mix
Part Number: 176003905
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Protein
Chemistry SEC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 300 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 200Å
QC Tested Protein
Silanol Activity Low
Surface Area 200
System UPLC/UHPLC
Technology BEH
USP Classification L33
Units in Package 1/pkg
pH Range 1 - 8

info

176003904 - ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 4.6 x 150 mm and BEH200 SEC Protein Standard Mix

Part Number: 176003904

Based upon the highly successful BEH particle technology, the new patent pending ACQUITY UPLC BEH200 SEC column represents the first commer­cially available sub 2 ìm SEC chemistry. Fully optimized for the analysis of proteins and their aggregates with molecular weights ranging from 10,000 to 450,000 Daltons, the total system solution will routinely deliver fast, accurate aggregate determinations up to 10 times quicker that traditional HPLC-based SEC methods.

176003904 - ACQUITY UPLC Protein BEH SEC Column, 200Å, 1.7 µm, 4.6 x 150 mm and BEH200 SEC Protein Standard Mix
Part Number: 176003904
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Protein
Chemistry SEC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode SEC/GPC
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 200Å
QC Tested Protein
Silanol Activity Low
Surface Area 220
System UPLC/UHPLC
Technology BEH
USP Classification L33
Units in Package 1/pkg
pH Range 1 - 8

info

176003701 - ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg with Glycoprotein Performance Test Standard

Part Number: 176003701

Waters Glycoprotein BEH Amide 300Å, 1.7 μm columns were primarily designed for the analysis of intact glycoproteins, glycoprotein fragments, and glycopeptides.. Each batch of Glycoprotein BEH Amide 300Å 1.7 μm material is specifically quality control tested with the Waters Glycoprotein Performance Test Standard (P/N 186008010 that includes a mixture of ribonuclease A as well as ribonulease B glycoforms) to help ensure batch to batch consistency. This kit includes one Glycoprotein BEH Amide 300Å, 1.7 μm column and one vial of Waters Glycoprotein Performance Test Standard. The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.

176003701 - ACQUITY UPLC Glycoprotein BEH Amide Column, 300Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg with Glycoprotein Performance Test Standard
Part Number: 176003701
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
VanGuard Pre-column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Glycoprotein
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L68
Units in Package 1/pkg
pH Range 2 - 10

info

176003066 - ACQUITY UPLC Peptide CSH C18 Column Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 176003066

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes one ACQUITY UPLC CSH130 C18 column and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.

176003066 - ACQUITY UPLC Peptide CSH C18 Column Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 176003066
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 11

info

176001744 - PFC Analysis Kit

Part Number: 176001744

Waters ACQUITY UPLC total solution for the analysis of Perfluorinated Compounds (PFCs). The kit contains ACQUITY BEH C18 column, PFC isolator column, and other PFCs-free components optimized for use with the ACQUITY system. Sample preparation consumables such as Oasis HLB cartridges, PFC calibration standards, PFC unknown QC standards, and sample vials are also included.

176001744 - PFC Analysis Kit
Part Number: 176001744
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column Kit

info

186008470 - ACQUITY UPLC M-Class BEH C4 Trap Column, 300Å, 5 µm, 300 µm X 50 mm, 1/pkg

Part Number: 186008470

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 300A pore, C4, 1.7um particles and each batch is specifically QC tested with a carefully selected protein standard mix to help ensure consistent performance and increased analytical column life.

186008470 - ACQUITY UPLC M-Class BEH C4 Trap Column, 300Å, 5 µm, 300 µm X 50 mm, 1/pkg
Part Number: 186008470
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 8
Chemistry C4
Endcapped No
Endfitting Type Parker-style
Format Trap Column
ID 300 µm
Length (mm) 50 mm
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
Silanol Activity Low
Surface Area 90
System Nano/Micro
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 10

info

186007497 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg

Part Number: 186007497

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007497 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg
Part Number: 186007497
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Trap Column
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System Nano/Micro
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007496 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg

Part Number: 186007496

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007496 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg
Part Number: 186007496
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Trap Column
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System Nano/Micro
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007484 - ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pkg

Part Number: 186007484

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007484 - ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pkg
Part Number: 186007484
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186007474 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 75 µm X 250 mm, 1/pkg

Part Number: 186007474

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007474 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 75 µm X 250 mm, 1/pkg
Part Number: 186007474
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007473 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 75 µm X 150 mm, 1/pkg

Part Number: 186007473

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007473 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 75 µm X 150 mm, 1/pkg
Part Number: 186007473
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007472 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pkg

Part Number: 186007472

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007472 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pkg
Part Number: 186007472
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 300 µm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007471 - ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pkg

Part Number: 186007471

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007471 - ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pkg
Part Number: 186007471
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Trap Column
ID 300 µm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT200839 - Acrodisc, Syringe Filter, PVDF, 25 mm, 0.2 µm, Protein, 1000/case

Part Number: WAT200839

This PVDF membrane works well with both aqueous and organic solvents

WAT200839 - Acrodisc, Syringe Filter, PVDF, 25 mm, 0.2 µm, Protein, 1000/case
Part Number: WAT200839
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 25 mm
Format Syringe Filter
Hold-up Volume < 100 µL
Housing Polypropylene
Pore Size 0.2 µm
Sample Volume < 100 mL
Separation Mode Protein
Solvent/Sample Compatible PVDF
Units in Package 1000/case

info

WAT200516 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pkg

Part Number: WAT200516

GHP has the broadest chemical compatibility and exhibits minimal protein binding

WAT200516 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pkg
Part Number: WAT200516
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 10 mL
Separation Mode Aqueous
Solvent/Sample Compatible GHP
Units in Package 100/pkg

info

WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg

Part Number: WAT200500

This PTFE membrane is a good choice for use with aggresive organic solvents

WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg
Part Number: WAT200500
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 25 mm
Format Syringe Filter
Hold-up Volume < 100 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 100 mL
Separation Mode Non polar
Solvent/Sample Compatible PTFE
Units in Package 50/pkg

info

WAT097963 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.2 µm, Aqueous, 300/case

Part Number: WAT097963

GHP has the broadest chemical compatibility and exhibits minimal protein binding

WAT097963 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.2 µm, Aqueous, 300/case
Part Number: WAT097963
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Polypropylene
Pore Size 0.2 µm
Sample Volume < 10 mL
Separation Mode Aqueous
Solvent/Sample Compatible GHP
Units in Package 300/case

info

WAT021902 - AP-1 Glass Column, 10x200 mm, 1/pkg

Part Number: WAT021902

Waters Advanced Purification (AP) glass columns are constructed of biocompatible glass and polymeric materials for use with silica, polymer, or soft gel packings.

WAT021902 - AP-1 Glass Column, 10x200 mm, 1/pkg
Part Number: WAT021902
Brand: Advanced Purification

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Protein
Endfitting Type Waters
Format AP Glass Column
ID 10 mm
Length (mm) 200 mm
Units in Package 1/pkg

info

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003962

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003962
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186003761 - Atlantis T3 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186003761

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003761 - Atlantis T3 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186003761
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186003708 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186003708

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003708 - Atlantis T3 OBD Prep Column, 100Å, 10 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186003708
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8