Product Listing:  186004775 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg   to   WAT270986 - Standard Flow Inlet Tubing Assembly

Sorted by Brand
  Product    
info

186004775 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004775

The HSS C18 is a general-purpose C18 bonded phase column that provides superior peak shape for bases, increased retention (vs. XBridge C18 columns), and exceptional column lifetimes at low pH. The selectivity and retention observed with HSS C18 columns will resemble that of most modern, fully endcapped, high-coverage silica-based C18 columns.

186004775 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004775
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

176003080 - XSelect Peptide CSH C18 Column Kit, Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176003080

Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes three XSelect CSH130 C18 columns packed with three different batches of sorbent and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.

176003080 - XSelect Peptide CSH C18 Column Kit, Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176003080
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186002263 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg

Part Number: 186002263

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002263 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg
Part Number: 186002263
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186001470 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001470

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186001470 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001470
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001147

XTerra Phenyl columns are hybrid-based, reversed-phase columns that incorporate phenyl ligand functionality. These first generation columns provide superior pH stability compared to a silica-based column.

186001147 - XTerra Phenyl Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001147
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 170
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186000878 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186000878

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000878 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186000878
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000863 - XTerra Shield RP18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 250 mm, 3/pkg

Part Number: 186000863

This kit consists of three XTerra RP 18 columns packed with three different batches of sorbent.

186000863 - XTerra Shield RP18 Method Validation Kit, 125Å, 5 µm, 4.6 mm X 250 mm, 3/pkg
Part Number: 186000863
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 12

info

186000632 - XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pkg

Part Number: 186000632

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000632 - XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pkg
Part Number: 186000632
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 2.1 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 12

info

186000602 - XTerra MS C18 Column, 125Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000602

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000602 - XTerra MS C18 Column, 125Å, 2.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000602
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000495 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000495

XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000495 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000495
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186000491 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000491

XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000491 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000491
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186000486 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186000486

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000486 - XTerra MS C18 Column, 125Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186000486
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000478 - XTerra MS C18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000478

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000478 - XTerra MS C18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000478
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186000435 - XTerra RP 8 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000435

XTerra RP8 columns are general purpose, hybrid-based, reversed-phase C8 columns that incorporate Waters patented embedded polar group technology to improve peak shape performance for highly basic compounds. These first generation columns provide superior pH stability compared to a silica-based column.

186000435 - XTerra RP 8 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000435
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13.5
Bonding Technology RP 8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 12

info

186000432 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186000432

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000432 - XTerra MS C18 Column, 125Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186000432
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT088070 - µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pkg

Part Number: WAT088070

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

WAT088070 - µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pkg
Part Number: WAT088070
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Format Guard-Pak Insert
Mode Reversed-Phase
Particle Size (dp) 10 µm
Pore Size 125Å
Units in Package 10/pkg

info

WAT046850 - µBondapak Phenyl Sentry Guard Cartridge, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046850

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

WAT046850 - µBondapak Phenyl Sentry Guard Cartridge, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046850
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.3
Chemistry Phenyl
Endcapped Yes
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L11
Units in Package 2/pkg
pH Range 2 - 8

info

JJAN84040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN84040

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

JJAN84040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN84040
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

JJAN27324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN27324

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

JJAN27324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN27324
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.8
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

JJAN27198 - µBondapak Phenyl Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN27198

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

JJAN27198 - µBondapak Phenyl Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN27198
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.3
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046860 - µPorasil Silica Guard Column, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046860

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

WAT046860 - µPorasil Silica Guard Column, 125Å, 10 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046860
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Guard Column
ID 3.9 mm
Length (mm) 20 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 2/pkg
pH Range 2 - 8

info

JJAN27477 - µPorasil Silica Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN27477

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

JJAN27477 - µPorasil Silica Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN27477
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT290188 - Microfuse 7A

Part Number: WAT290188

This spare part is a Waters Quality part.

WAT290188 - Microfuse 7A
Part Number: WAT290188
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module

info

WAT271082 - Solvent Bottle Tray

Part Number: WAT271082

The Solvent Bottle Tray holds four 1-Liter bottles. The solvents should be placed above the gradient proportioning valve.

WAT271082 - Solvent Bottle Tray
Part Number: WAT271082
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module

info

WAT271067 - Plunger, Oriented (Optional)

Part Number: WAT271067

Made from the highest quality sapphire, this plunger preserves the life span of the plunger seal. The oriented crystalline structure of this sapphire plunger ensures a harder, smoother exterior surface than a standard plunger, making it even less susceptible to wear. Precise roundness and smoothness tolerances minimize the wear of the plunger seal, while alignment of the plunger within its stainless steel holder ensures that the sapphire rides directly into the center of the plunger seal, reducing wear of both parts while safeguarding pump flow rates and system retention times. Included with the plunger is a pre-mounted C-Clip, which saves remounting time.

WAT271067 - Plunger, Oriented (Optional)
Part Number: WAT271067
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Plungers
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module

info

WAT271066 - Plunger Seals Replacement Kit (Black) 2/Pkg

Part Number: WAT271066

These optional (black) plunger seals for Waters® Alliance Solvent Management Systems are good alternatives if the standard seal (P/N WAT270938) does not perform well for your specific application.

WAT271066 - Plunger Seals Replacement Kit (Black) 2/Pkg
Part Number: WAT271066
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Replacement Schedule Annually

info

WAT271019 - Seal Pack Rebuild Kit w/Needle

Part Number: WAT271019

The Seal Pack Rebuild Kit includes all of the parts necessary to replace seals in the seal body, including the high pressure seals. Replacement of these seals requires use of HPMV Tool Kit (WAT045427). The Rebuild Kit includes: one Teflon washer, one needlewash filter, one upper spacer, one lower spacer, one alignment tube, one wash tube seal, one needle, two high pressure seals, one compression screw, and one ferrule.

WAT271019 - Seal Pack Rebuild Kit w/Needle
Part Number: WAT271019
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module

info

WAT271018 - Seal Wash, Plunger Seal, Replacement Kit 2/Pkg

Part Number: WAT271018

Integral to the 2690 and 2790 Separations Modules, these seals are part of the seal wash system and help ensure that plunger seal life is maximized.

WAT271018 - Seal Wash, Plunger Seal, Replacement Kit 2/Pkg
Part Number: WAT271018
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems

info

WAT271017 - Seal Wash Face Seal Kit,1/Pkg

Part Number: WAT271017

Integral to the 2690 and 2790 Separations Modules, these seals are part of the seal wash system and help ensure that plunger seal life is maximized.

WAT271017 - Seal Wash Face Seal Kit,1/Pkg
Part Number: WAT271017
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems

info

WAT270986 - Standard Flow Inlet Tubing Assembly

Part Number: WAT270986

The Standard Flow Inlet Tubing Assembly is 0.030in ID stainless steel tubing and is surrounded by blackTeflon tubing.

WAT270986 - Standard Flow Inlet Tubing Assembly
Part Number: WAT270986
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module