Product Listing:  186000349DV - 96 well plate with deactivated 700uL glass inserts, 1pkg   to   186003041 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Sorted by Brand
  Product    
info

186000349DV - 96 well plate with deactivated 700uL glass inserts, 1pkg

Part Number: 186000349DV

Deactivated vials have a silanized surface to prevent adsorption of highly polar molecules.

186000349DV - 96 well plate with deactivated 700uL glass inserts, 1pkg
Part Number: 186000349DV
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Certified Not Certified
Format 96 Well Plates
GlassType Deactivated
Units in Package 1/pkg
Volume Capacity 700 µL

info

186000302 - Clear Glass 12 x 32mm Snap Neck Total Recovery Vial, 1 mL Volume, 100/pkg

Part Number: 186000302

Waters offers a selection of snap cap vials and snap caps/septa.

186000302 - Clear Glass 12 x 32mm Snap Neck Total Recovery Vial, 1 mL Volume, 100/pkg
Part Number: 186000302
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2695
Certified Not Certified
Closure Type Snap Neck
Dimensions 12 x 32mm
Format Total Recovery Vial
GlassType Clear Glass
Units in Package 100/pkg
Volume Capacity 1 mL

info

176003466 - Empower 3 Sample Set Generator

Part Number: 176003466

The Sample Set Generator provides automation capabilities in the creation of Instrument Methods, Method Sets and Sample Set Methods for method development and validtion worklows using Empower 3 Software.

176003466 - Empower 3 Sample Set Generator
Part Number: 176003466
Products > Chromatography Consumables & Columns > Accessories
Product Compatibility Empower 3 all versions
Quantity 1

info

064 - 125ml Silica

Part Number: 064

Silica, Ion Calibration Standard 1000mg/L. This 1000 mg/L standard can be used for primary calibration or to prepare second source calibration check standards. It is traceable to NIST Standard Reference Materials, where available, and is guaranteed stable for one year.

064 - 125ml Silica
Part Number: 064
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Environment
Product Type Standard
Shipping Formulation Liquid

info

044 - 125ml Ammonia NH3

Part Number: 044

Ammonia as NH3 Ion Calibration Standard 1000mg/L Martix H2O. This 1000 mg/L standard can be used for primary calibration or to prepare second source calibration check standards. It is traceable to NIST Standard Reference Materials, where available, and is guaranteed stable for one year.

044 - 125ml Ammonia NH3
Part Number: 044
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Environment
Product Type Standard
Shipping Formulation Liquid

info

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001265

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001265 - Waters PAH C18 Column, 120Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001265
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

186001260 - Waters PAH C18 Column, 120Å, 3 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186001260

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001260 - Waters PAH C18 Column, 120Å, 3 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186001260
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

186008212 - XBridge Oligonucleotide BEH C18 OBD Prep Column, 130Å, 2.5 µm, 10 mm X 50 mm, 1/pkg

Part Number: 186008212

Waters Oligonucleotide Separation Technology columns are based on the second generation of hybrid-silica BEH Technology particles functionalized with C18. The separation of detritylated synthetic oligonucleotide samples is based on the well-established method of ion-pair, reversed-phase chromatography. The availability of 1.7µm UPLC technology or 2.5µm HPLC particles in various column dimensions provides flexibility to meet various laboratory-scale isolation or analysis needs and delivers exceptional sample resolution and superior column life. In addition, Waters manufacturing and quality control testing procedures help ensure consistent batch-to-batch and column-to-column performance regardless of application demands.

186008212 - XBridge Oligonucleotide BEH C18 OBD Prep Column, 130Å, 2.5 µm, 10 mm X 50 mm, 1/pkg
Part Number: 186008212
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Oligonucleotides Separations > Oligonucleotides Separation Technology Columns
Application Oligonucleotide
Chemistry C18
Format OBD Prep Column
ID 10 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 2.5 µm
Pore Size 130Å
QC Tested Oligonucleotide
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg

info

186007313 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186007313

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007313 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186007313
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

186007273 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186007273

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007273 - XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186007273
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007270

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007270 - XBridge Glycan BEH Amide Column, 130Å, 2.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007270
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186007265

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007265 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186007265
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186007264 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186007264

Waters BEH-based Glycan chemistry offerings are available in three highly scalable particle sizes that address UPLC (i.e, 1.7 µm) and HPLC-based (2.5 µm XP and 3.5 µm) application needs. Each batch of BEH Glycan material is specifically quality control tested with the 2-AB labeled, Waters Glycan Performance standard to help ensure batch to batch consistency as well as highly similar separated glycan profiles. To help ensure highly similar results, chromatographers can now choose the most appropriate LC-based technology to address their specific released glycan analysis application needs and laboratory instrumentation.

186007264 - XBridge Glycan BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186007264
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 12
Application Glycan
Chemistry Amide
Endcapped No
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Glycan
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006091 - XBridge BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186006091

XBridge BEH Amide columns retain extremely polar compounds, including carbohydrates and sugars. XBridge Amide columns offer you a chemically stable, trifunctionally bonded amide phase that is stable from pH 2 to 11 to enable the separation of polar analytes spanning a wide range of polarity, structural moiety and pKa. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006091 - XBridge BEH Amide XP Column, 130Å, 2.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186006091
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Chemistry Amide
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
Units in Package 1/pkg
pH Range 2 - 11

info

186006041 - XBridge BEH C8 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006041

The XBridge BEH C8 sorbent is less retentive compared to the XBridge BEH C18 sorbent. Anyone developing methods may prefer the speed offered by a less retentive column, while improving peak shape and chromatographic performance. The trifunctionally bonded sorbent offers you the widest usable pH range (1-12), superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006041 - XBridge BEH C8 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006041
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 13
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186006029 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186006029

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed. Packed in ultra-low dispersion hardware, 2.5 µm eXtended Performance [XP] columns enable exceptional separation performance, robustness and throughput for HPLC assays while enabling a seamless transition path toward UPLC adoption.

186006029 - XBridge BEH C18 XP Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186006029
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format XP Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186005465 - XBridge Protein BEH C4 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186005465

The reproducibility of a chromatographic column has a critical impact on the long-term reliability and robustness of an analytical method, and its reproducibility lies completely outside the user's control. With exceptional batch-to-batch and column-to-column reproducibility, Waters well-established particle and column manufacturing process control provides confidence in the long-term reliability of your analytical method. XBridge BEH300 C4, 3.5um Method Validation Kit includes three batches of chromatographic media [derived from different base particles] to judge the quality, reliability, and consistency of your chromatographic method. Each batch of selected XBridge BEH300 C18, 3.5um chemistry is specifically QC tested with a mixture of carefully selected protein standards to help ensure consistent performance.

186005465 - XBridge Protein BEH C4 Method Validation Kit, 300Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186005465
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 3/pkg
pH Range 1 - 10

info

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004504

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004504 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004504
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg

Part Number: 186004500

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004500 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 150 mm, 10K - 500K, 1/pkg
Part Number: 186004500
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg

Part Number: 186004498

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg
Part Number: 186004498
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186004454 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004454

XBridge BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186004454 - XBridge BEH HILIC Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004454
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186003965 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003965

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003965 - XBridge BEH Phenyl Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003965
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003964

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003964 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003964
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186003770 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186003770

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003770 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186003770
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186003769 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg

Part Number: 186003769

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003769 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 100 mm, 3/pkg
Part Number: 186003769
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Method Validation Kit
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003581

The XBridge BEH130 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003581 - XBridge Peptide BEH C18 Column, 130Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003581
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186003352 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003352

XBridge BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This most chemically stable commercially available Phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003352 - XBridge BEH Phenyl Column, 130Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003352
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186003070 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186003070

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003070 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186003070
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 11

info

186003069 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 3 mm X 20 mm, 2/pkg

Part Number: 186003069

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003069 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 3 mm X 20 mm, 2/pkg
Part Number: 186003069
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 11

info

186003041 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186003041

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003041 - XBridge BEH Shield RP18 Column, 130Å, 3.5 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186003041
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11