Product Listing:  186003534 - ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pkg   to   WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm

Sorted by Brand
  Product    
info

186003534 - ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003534

ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.

186003534 - ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003534
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

186003533 - ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186003533

ACQUITY UPLC HSS C18 chemistry is an ultra-performance general purpose C18 bonded phase that provides superior peak shape for bases, increased retention (vs. ACQUITY UPLC BEH C18 columns), and extremely long column lifetimes at low pH. ACQUITY HSS C18 columns are fully scalable and transferable to HPLC separations.

186003533 - ACQUITY UPLC HSS C18 Column, 100Å, 1.8 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186003533
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003462

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186003462 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003462
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186003461 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186003461

ACQUITY BEH HILIC columns contain unbonded BEH substrate and are designed to retain and separate very polar compounds. These unique columns are optimized and tested to produce efficient, reproducible separations under HPLC HILIC conditions. More rugged than silica based HILIC phases, the BEH particle’s chemical stability results in long column lifetimes.

186003461 - ACQUITY UPLC BEH HILIC Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186003461
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Chemistry HILIC
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 9

info

186003378 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186003378

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186003378 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186003378
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186002885 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186002885

ACQUITY BEH Phenyl columns provide complementary selectivity to C18 stationary phases, especially for polyaromatic compounds. This sorbent, along with the XBridge BEH Phenyl, provide you with the most chemiscally stable phenyl sorbent on the market and provides you with ultra-low column bleed, long column lifetimes and excellent peak shape.

186002885 - ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186002885
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L11
Units in Package 1/pkg
pH Range 1 - 12

info

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186002854

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002854 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186002854
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186002853 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002853

ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186002853 - ACQUITY UPLC BEH Shield RP18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002853
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 11

info

186002352 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186002352

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

186002352 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186002352
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002350

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

186002350 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002350
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

176001048 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 176001048

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications.

176001048 - ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 176001048
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

WAT200827 - Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 1000/case

Part Number: WAT200827

This PVDF membrane works well with both aqueous and organic solvents

WAT200827 - Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 1000/case
Part Number: WAT200827
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Syringe Filter
Hold-up Volume < 30 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 10 mL
Separation Mode Protein
Solvent/Sample Compatible PVDF
Units in Package 1000/case

info

WAT200512 - Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 100/pkg

Part Number: WAT200512

This PVDF membrane works well with both aqueous and organic solvents

WAT200512 - Acrodisc, Syringe Filter, PVDF, 13 mm, 0.45 µm, Protein, 100/pkg
Part Number: WAT200512
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Syringe Filter
Hold-up Volume < 30 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 10 mL
Separation Mode Protein
Solvent/Sample Compatible PVDF
Units in Package 100/pkg

info

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003748

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003748
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003729 - Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003729

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003729 - Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003729
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002033

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002033
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186002011 - Atlantis Silica HILIC Column, 100Å, 3 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002011

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002011 - Atlantis Silica HILIC Column, 100Å, 3 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002011
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001346

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001346
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001344

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001344
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001342 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001342

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001342 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001342
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186001337

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186001337
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001299 - Atlantis dc18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186001299

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001299 - Atlantis dc18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186001299
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001293 - Atlantis dc18 Column, 100Å, 5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186001293

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001293 - Atlantis dc18 Column, 100Å, 5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186001293
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084038

The Carbohydrate Analysis Column features a covalently bonded amino packing that is ideally suited for the seperation of low molecular weight sugars such as mono,di-, and trisaccharides. This column typically uses a mobile phase consisting of 65-85% acetonitrile in water and a column temperature ranging from ambient to 35° C.

WAT084038 - Carbohydrate Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084038
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Amino (NH2)
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

WAT044355 - Carbohydrate Cartridge Column, 4.6 x 250 mm

Part Number: WAT044355

Waters High-Performance Carbohydrate Cartridge Column is packed with 4-μm spherical silica. This column was developed to separate five monosaccharides and disaccharides to give baseline resolution in fewer than 12 minutes. The pre-packed, disposable cartridge column requires reusable end-fittings, which are available separately.

WAT044355 - Carbohydrate Cartridge Column, 4.6 x 250 mm
Part Number: WAT044355
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
USP Classification L8
Units in Package 1/pkg

info

186007114 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186007114

CORTECS C18+ columns are general purpose, high efficiency C18 columns based on a solid-core particle that are designed to deliver excellent peak shape for basic analytes at low pH.

186007114 - CORTECS UPLC C18+ Column, 90Å, 1.6 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186007114
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002780 - GlycoWorks HILIC uElution Plate

Part Number: 186002780

This plate is ideal for removing contaminants like salts and detergents from hydrophilic analytes, such as carbohydrates, prior to mass spectrometry analysis. It enables elution volumes as low as 25 µL, thereby eliminating time-consuming evaporation steps. The eluted carbohydrates can be analyzed directly by MALDI MS without any prior derivatization. This plate can be used alone for the purpose of extracting carbohydrates, or it can be used as part of our glycan analysis kit (Waters MassPREP Glycoanalysis Kit) to clean up the glycans released from glycoproteins after deglycosylation.

186002780 - GlycoWorks HILIC uElution Plate
Part Number: 186002780
Brand: GlycoWorks

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Column Chemistry HILIC
Detector Fluorescence (FLR)
Packaging 1/pkg
Product Type Kit
Shipping Formulation Solid
Storage Room temp
System LC/MS

info

WAT010295 - Ion Exclusion Column, 7 µm, 7.8 x 150 mm

Part Number: WAT010295

IC-Pak Ion Exclusion columns are used for the analysis of weak acid anions such as fluoride and short chain organic acids from formate to butyrate.

WAT010295 - Ion Exclusion Column, 7 µm, 7.8 x 150 mm
Part Number: WAT010295
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Ion Exclusion
Format Column
ID 7.8 mm
Length (mm) 150 mm
Mode Ion-Exclusion
Particle Size (dp) 7 µm
Units in Package 1/pkg

info

WAT010290 - Ion Exclusion Column, 7 µm, 7.8 x 300 mm

Part Number: WAT010290

IC-Pak Ion Exclusion columns are used for the analysis of weak acid anions such as fluoride and short chain organic acids from formate to butyrate.

WAT010290 - Ion Exclusion Column, 7 µm, 7.8 x 300 mm
Part Number: WAT010290
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Ion Exclusion
Format Column
ID 7.8 mm
Length (mm) 300 mm
Mode Ion-Exclusion
Particle Size (dp) 7 µm
Units in Package 1/pkg

info

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm

Part Number: WAT026770

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT026770 - IC-Pak Anion HC Column, 4.6 x 150 mm
Part Number: WAT026770
Brand: IC-Pak HC

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Anion-exchange
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg