Product Listing:  WAT200839 - Acrodisc, Syringe Filter, PVDF, 25 mm, 0.2 µm, Protein, 1000/case   to   186007377 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Sorted by Brand
  Product    
info

WAT200839 - Acrodisc, Syringe Filter, PVDF, 25 mm, 0.2 µm, Protein, 1000/case

Part Number: WAT200839

This PVDF membrane works well with both aqueous and organic solvents

WAT200839 - Acrodisc, Syringe Filter, PVDF, 25 mm, 0.2 µm, Protein, 1000/case
Part Number: WAT200839
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 25 mm
Format Syringe Filter
Hold-up Volume < 100 µL
Housing Polypropylene
Pore Size 0.2 µm
Sample Volume < 100 mL
Separation Mode Protein
Solvent/Sample Compatible PVDF
Units in Package 1000/case

info

WAT200516 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pkg

Part Number: WAT200516

GHP has the broadest chemical compatibility and exhibits minimal protein binding

WAT200516 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.45 µm, Aqueous, 100/pkg
Part Number: WAT200516
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 10 mL
Separation Mode Aqueous
Solvent/Sample Compatible GHP
Units in Package 100/pkg

info

WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg

Part Number: WAT200500

This PTFE membrane is a good choice for use with aggresive organic solvents

WAT200500 - Acrodisc, Syringe Filter, PTFE, 25 mm, 0.45 µm, Non polar, 50/pkg
Part Number: WAT200500
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 25 mm
Format Syringe Filter
Hold-up Volume < 100 µL
Housing Polypropylene
Pore Size 0.45 µm
Sample Volume < 100 mL
Separation Mode Non polar
Solvent/Sample Compatible PTFE
Units in Package 50/pkg

info

WAT027502 - AP-2 Glass Column, 20x200 mm, 1/pkg

Part Number: WAT027502

Complete AP-2 Glass Column, 20x200 mm

WAT027502 - AP-2 Glass Column, 20x200 mm, 1/pkg
Part Number: WAT027502
Brand: Advanced Purification

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Protein
Endfitting Type Waters
Format AP Glass Column
ID 20 mm
Length (mm) 200 mm
Units in Package 1/pkg

info

WAT021902 - AP-1 Glass Column, 10x200 mm, 1/pkg

Part Number: WAT021902

Waters Advanced Purification (AP) glass columns are constructed of biocompatible glass and polymeric materials for use with silica, polymer, or soft gel packings.

WAT021902 - AP-1 Glass Column, 10x200 mm, 1/pkg
Part Number: WAT021902
Brand: Advanced Purification

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Protein
Endfitting Type Waters
Format AP Glass Column
ID 10 mm
Length (mm) 200 mm
Units in Package 1/pkg

info

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg

Part Number: 186003962

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186003962 - Atlantis Silica HILIC OBD Prep Column, 100Å, 5 µm, 30 mm X 150 mm, 1/pkg
Part Number: 186003962
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186003761 - Atlantis T3 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186003761

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003761 - Atlantis T3 Sentry Guard Cartridge, 100Å, 5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186003761
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 8

info

186003713 - Atlantis T3 Column, 100Å, 3 µm, 1 mm X 50 mm, 1/pkg

Part Number: 186003713

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003713 - Atlantis T3 Column, 100Å, 3 µm, 1 mm X 50 mm, 1/pkg
Part Number: 186003713
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003699 - Atlantis T3 Prep Guard Cartridge, 100Å, 5 µm, 19 mm X 10 mm, 1/pkg

Part Number: 186003699

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003699 - Atlantis T3 Prep Guard Cartridge, 100Å, 5 µm, 19 mm X 10 mm, 1/pkg
Part Number: 186003699
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Guard Cartridge
ID 19 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002030 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002030

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002030 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002030
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186002015 - Atlantis Silica HILIC Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186002015

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002015 - Atlantis Silica HILIC Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186002015
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186001319 - Atlantis dc18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186001319

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001319 - Atlantis dc18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186001319
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186002432 - BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002432

BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.

186002432 - BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002432
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002430 - BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002430

BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.

186002430 - BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002430
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002427 - BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186002427

BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.

186002427 - BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186002427
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Chemistry C18
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002425 - BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186002425

BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.

186002425 - BioSuite C18 Column, 100Å, 3 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186002425
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Chemistry C18
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002159 - BioSuite Phenyl Column, 1000Å, 10 µm, 7.5mm X 75 mm, 1/pkg

Part Number: 186002159

The separation of proteins and peptides based upon hydrophobic characteristics is a powerful chromatographic technique. However, some proteins denature at elevated organic solvent concentrations making reversed-phase chromatography (RPC) difficult. Waters BioSuite™ Phenyl HIC columns provide a viable separation alternative to RPC. HIC is characterized by the adsorption of compounds to a weakly hydrophobic surface at high salt concentrations, followed by elution with a decreasing salt gradient. HIC combines the non-denaturing characteristics of salt precipitation with the precision of HPLC to yield excellent separation of biologically active material. Waters BioSuite™ Phenyl, 1000, 10 µm HIC column media consists of a phenyl group bonded to a methacrylic ester-based polymeric resin. The large 1000 angstrom pore size accommodates proteins up to 5,000,000 Daltons. A 21.5 mm x 150 mm column is also available for "labscale" isolations.

186002159 - BioSuite Phenyl Column, 1000Å, 10 µm, 7.5mm X 75 mm, 1/pkg
Part Number: 186002159
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Chemistry Phenyl
Endfitting Type Parker-style
Format Column
ID 7.5mm
Length (mm) 75 mm
Mode Hydrophobic Interaction
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Polymer
Pore Size 1000Å
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 12

info

JJAN25875 - Bondapak C18 Column, 125Å, 15-20 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: JJAN25875

Bondapak C18 is available in two different particle sizes, 15-20µm and 37-55µm, providing easy method transfer from µBondapak through preparative scale up. If you are developing a new purification protocol, Bondapak provides the best balance between resolution, throughput and cost.

JJAN25875 - Bondapak C18 Column, 125Å, 15-20 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: JJAN25875
Brand: Bondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 10
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 15-20 µm
Particle Substrate Silica
Pore Size 125Å
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046895 - Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg

Part Number: WAT046895

The Carbohydrate Sentry Guard Cartridge is used to extend and prolong the lifetime for the Carbohydrate Cartridge Column by removing chemical and particulate contaminants from the mobile phase stream.

WAT046895 - Carbohydrate Sentry Guard Cartridge, 60Å, 4 µm, 3.9 mm X 20 mm, 2/pkg
Part Number: WAT046895
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Sentry Guard Cartridge
ID 3.9 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
USP Classification L20
Units in Package 2/pkg

info

186008662 - CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186008662

CORTECS Shield RP18 columns provides complimentary selectivity to C8 and C18 stationary phases. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns. The solid core particle morphology offers high efficiency and lower backpressures when compared to fully porouse particles of similar particle size.

186008662 - CORTECS Shield RP18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186008662
Brand: CORTECS

Products > Chromatography Consumables & Columns
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008499 - CORTECS UPLC T3 Column, 120Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186008499

CORTECS T3 columns are compatible with 100% aqueous mobile phases, and provide excellent retention for polar and non-polar analytes. The particle morphology offers high efficnecy and lower backpressure when compared to fully porouse particles of similar particle size. CORTECS T3 provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008499 - CORTECS UPLC T3 Column, 120Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186008499
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.7
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Silica
Pore Size 120Å
Silanol Activity Low
Surface Area 100
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008496 - CORTECS UPLC T3 Column, 120Å, 1.6 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186008496

CORTECS T3 columns are compatible with 100% aqueous mobile phases, and provide excellent retention for polar and non-polar analytes. The particle morphology offers high efficnecy and lower backpressure when compared to fully porouse particles of similar particle size. CORTECS T3 provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008496 - CORTECS UPLC T3 Column, 120Å, 1.6 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186008496
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.7
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Silica
Pore Size 120Å
Silanol Activity Low
Surface Area 100
Technology UPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008495 - CORTECS T3 Column, 120Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186008495

CORTECS T3 columns are compatible with 100% aqueous mobile phases, and provide excellent retention for polar and non-polar analytes. The particle morphology offers high efficnecy and lower backpressure when compared to fully porouse particles of similar particle size. CORTECS T3 provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008495 - CORTECS T3 Column, 120Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186008495
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.7
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 120Å
Silanol Activity Low
Surface Area 100
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008494 - CORTECS T3 Column, 120Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186008494

CORTECS T3 columns are compatible with 100% aqueous mobile phases, and provide excellent retention for polar and non-polar analytes. The particle morphology offers high efficnecy and lower backpressure when compared to fully porouse particles of similar particle size. CORTECS T3 provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008494 - CORTECS T3 Column, 120Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186008494
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.7
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 120Å
Silanol Activity Low
Surface Area 100
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186008401 - CORTECS C8 Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186008401

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008401 - CORTECS C8 Column, 90Å, 1.6 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186008401
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008371 - CORTECS C8 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186008371

CORTECS C8 columns are used for general purpose method development under low pH test conditions. The C8 ligand is preferred for some assays because it is less hydrophobic and therefore less retetntive compared to C18 phases.

186008371 - CORTECS C8 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186008371
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 4.5
Chemistry C8
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186008341 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186008341

CORTECS Phenyl columns provide complimentary selectivity to C18 stationary phases. The particle morphology offers high efficnecy and lower backpressures when compared to fully porouse particles of similar particle size. CORTECS Phenyl provides you with ultra-low column MS bleed, long lifetimes and excellent peak shape.

186008341 - CORTECS Phenyl Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186008341
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.9
Chemistry Phenyl
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Silica
Pore Size 90Å
Silanol Activity Low
Surface Area 100
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8

info

186007685 - CORTECS C18+ VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007685

CORTECS C18+ VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. CORTECS C18+ analytical columns containing 2.7 µm sorbent particles.

186007685 - CORTECS C18+ VanGuard Cartridge, 90Å, 2.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007685
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 5.7
Bonding Technology C18+
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format VanGuard Cartridge
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186007378 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186007378

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007378 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186007378
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007377 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186007377

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007377 - CORTECS C18 Column, 90Å, 2.7 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186007377
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8