Product Listing:  186002263 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg   to   WAT057919 - Analytical Cell Assembly, 10mm

Sorted by Popularity
  Product    
info

186002263 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg

Part Number: 186002263

XTerra Prep columns bring the benefits of Hybrid Particle Technology to isolation and purification applications in discovery and development laboratories. XTerra Prep MS columns possess our patented Hybrid Particle Technology, with particles engineered specifically for prep. It allows you to routinely operate at pH 1-12 so you can load up to 60X more onto the column. More capacity results in fewer injections for the same amount of pure material or more material with the same number of injections. In the discovery world, this greater capacity means you can use a shorter column, producing the same amount of material in half the time.

186002263 - XTerra MS C18 OBD Prep Column, 125Å, 10 µm, 19 mm X 300 mm, 1/pkg
Part Number: 186002263
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 10 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

205000436 - Flow Splitter, 2.0-8.0mL, 100:1

Part Number: 205000436

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000436 - Flow Splitter, 2.0-8.0mL, 100:1
Part Number: 205000436
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000437 - Flow Splitter, 8.0-30mL, 1000:1

Part Number: 205000437

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000437 - Flow Splitter, 8.0-30mL, 1000:1
Part Number: 205000437
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

205000439 - Flow Splitter, 30-100mL, 5000:1

Part Number: 205000439

Flow Splitters are necessary for fraction collection in purification They help to achieve optimum flow rates for detector efficiency, even when destructive detectors such as evaporative light scattering or mass spectrometers are used.

205000439 - Flow Splitter, 30-100mL, 5000:1
Part Number: 205000439
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products System Fluidics Organizer
Replacement Schedule As Needed

info

201000260 - ACQUITY I-Class BSM 18K Performance Maintenance Kit

Part Number: 201000260

The Waters® Performance Maintenance Kit for the ACQUITY I-Class Binary Solvent Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: plungers, check valves, seals and filters.

201000260 - ACQUITY I-Class BSM 18K Performance Maintenance Kit
Part Number: 201000260
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY I-Class BSM
Replacement Schedule Annually

info

205000399 - 2998 Analytical Flow Cell Kit

Part Number: 205000399

This spare part is a Waters Quality part.

205000399 - 2998 Analytical Flow Cell Kit
Part Number: 205000399
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2998 Photodiode Array Detector
Replacement Schedule As Needed

info

205000401 - 2998 Semi-Preparative Flow Cell Kit

Part Number: 205000401

This spare part is a Waters Quality part.

205000401 - 2998 Semi-Preparative Flow Cell Kit
Part Number: 205000401
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2998 Photodiode Array Detector
Replacement Schedule As Needed

info

205000402 - 2998 Autopurification. Flow Cell

Part Number: 205000402

This spare part is a Waters Quality part.

205000402 - 2998 Autopurification. Flow Cell
Part Number: 205000402
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2998 Photodiode Array Detector
Replacement Schedule As Needed

info

201000220 - QUATTRO ULTIMA/PT PERFORMANCE MAINTENANCE KIT

Part Number: 201000220

The Waters® Performance Maintenance Kit for the Quattro Ultima/Ultima Pt Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit for the Quattro Ultima/Ultima Pt Mass Spectrometer includes the following parts: Source components, ESI probe components and vacuum pump components. The original part number was 201000175. This particular part numberdoes not deliver a chemical kit which is required to complete the performance testing. The Performance Maintenance Kit with Chemical Kit is 176002055.

201000220 - QUATTRO ULTIMA/PT PERFORMANCE MAINTENANCE KIT
Part Number: 201000220
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Replacement Schedule Annually

info

700001219 - 2695 Degasser Tray

Part Number: 700001219

This spare part is a Waters Quality part.

700001219 - 2695 Degasser Tray
Part Number: 700001219
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
Replacement Schedule As Needed

info

201000215 - QUATTRO PREMIER/XE (SCROLL) PERFORMANCE MAINTENANCE KIT

Part Number: 201000215

The Waters® Performance Maintenance Kit for the Quattro Premier/XE (scroll) Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit for the Quattro Premier/XE (scroll) Mass Spectrometer includes the following parts: Source components, ESI probe components and vacuum pump components. The original part number was 201000180. This particular part number does not deliver a chemical kit which is required to complete the performance testing. The part number for a Waters® Performance Maintenance Kit and a chemical kit is 176002054.

201000215 - QUATTRO PREMIER/XE (SCROLL) PERFORMANCE MAINTENANCE KIT
Part Number: 201000215
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
Replacement Schedule Annually

info

700001198 - ZQ/ Quattro Micro Ion Block Assembly

Part Number: 700001198

Ion Block Assembly containing the sample cone, cone gas cone, extraction lens and o-ring.

700001198 - ZQ/ Quattro Micro Ion Block Assembly
Part Number: 700001198
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Quattro micro Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule No
sparepartsystemscategory LCMS

info

700000432 - 3 Column Select Valve

Part Number: 700000432

The 3-Column Selection Valve is an 8-port, 3-position valve that allows selection among 3 column positions. The tubing for the 3-column selection valve is installed at the factory. The 3-column selection valve can switch between columns, bypass to the detector using a small restrictor, or bypass to waste.

700000432 - 3 Column Select Valve
Part Number: 700000432
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Separations Module
Products 2790 Separations Module
2795 Separations Module
System Fluidics Organizer
Replacement Schedule No

info

201000224 - QTOF ULTIMA PERFORMANCE MAINTENANCE KIT

Part Number: 201000224

The Waters® Performance Maintenance Kit for the Q-Tof Ultima Mass Spectrometer contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Source component, ESI probe components and vacuum pump components. This particular part number does not deliver a chemical kit which is required to complete the performance testing. Performance Maintenance Kit with Chemical Kit part number is 176002076.

201000224 - QTOF ULTIMA PERFORMANCE MAINTENANCE KIT
Part Number: 201000224
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products Q-Tof Ultima API Mass Spectrometer
Replacement Schedule Annually

info

186002570 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pkg

Part Number: 186002570

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002570 - SunFire C18 OBD Prep Column, 100Å, 5 µm, 30 mm X 50 mm, 1/pkg
Part Number: 186002570
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format OBD Prep Column
ID 30 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700000380 - 2790/2795 Injector

Part Number: 700000380

The 2790/2795 Injector is a fixed-loop Rheodyne injector valve which is mounted horizontally under the sample compartment. The injector valve interfaces with the needle through an inject port that threads directly into the inject valve. The inject port contains an injector port seat and seal washer. A reverse-threaded nut connects the inject port to the bottom of the wash station block.

700000380 - 2790/2795 Injector
Part Number: 700000380
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Products 2790 Separations Module
2795 Separations Module
Replacement Schedule No

info

WAT082823 - Gradient Proportioning Valve

Part Number: WAT082823

The Gradient Proportioning Valve Assembly is a set of four 2-way valves, which features opening and closing rates and aperture sizes of an exceptionally tight tolerance. The four inlet valves are actuated by solenoids that have precise electrical characteristics to help reduce heat buildup and protect the system from outgassing. The gradient proportioning valve provides exact, reproducible mixing of up to four different solvents.

WAT082823 - Gradient Proportioning Valve
Part Number: WAT082823
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products PrepLC 4000
Replacement Schedule No

info

WAT045438 - High Pressure Motorized Valve Assembly

Part Number: WAT045438

The High Pressure Motorized Valve (HPMV) is a three-way valve that has two common ports and one controllable port. The HPMV is used in two of the three valve positions in the Fluids Pak: V1 (High Pressure Inject Valve) and V2 (High Pressure Syringe Valve). The basic valve is driven by a stepper motor.

WAT045438 - High Pressure Motorized Valve Assembly
Part Number: WAT045438
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Injectors
Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
LC Module 1
Replacement Schedule As Needed

info

201000174 - ACQUITY SAMPLE MANAGER PERFORMANCE MAINTENANCE KIT

Part Number: 201000174

The Waters® Performance Maintenance Kit for the ACQUITY Sample Manager contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: air chassis filter, injector outlet tubes, needle, system outlet tubes, inject valve pod, wash syringe, injector syringe, sample loop and o-ring.

201000174 - ACQUITY SAMPLE MANAGER PERFORMANCE MAINTENANCE KIT
Part Number: 201000174
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY UPLC Sample Manager
Replacement Schedule Annually

info

700001829 - Rheodyne RV703-104

Part Number: 700001829

The Rheodyne RV703-104 is a 7-port, 3-position injector valve (analytical)

700001829 - Rheodyne RV703-104
Part Number: 700001829
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Pumps
Products Column/Fluidics Organizer
Replacement Schedule No

info

WAT025822 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 19 mm X 300 mm, 1/pkg

Part Number: WAT025822

Nova-Pak HR C18 columns are silica-based, semi-preparative and preparative columns that are based on 6 µm particle technology. Compared to a 5 µm column, Nova-Pak HR columns offer higher resolution, more efficient separations, and faster chromatography.

WAT025822 - Nova-Pak C18 Prep Column, 60Å, 6 µm, 19 mm X 300 mm, 1/pkg
Part Number: WAT025822
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Prep Column
ID 19 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 6 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

201000259 - ACQUITY I-CLASS SMP MGR-FTN PERFORMANCE MAINTENANCE KIT

Part Number: 201000259

The Waters® Performance Maintenance Kit for the ACQUITY I-Class Sample Manager - Flow Through Needle contains all the Waters Quality Parts® necessary to keep your instrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: syringe, std needle, needle seat, injection cartridge and filters.

201000259 - ACQUITY I-CLASS SMP MGR-FTN PERFORMANCE MAINTENANCE KIT
Part Number: 201000259
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY I-Class SM-FTN
Replacement Schedule Annually

info

201000197 - ACQUITY I2V BSM PERFORMANCE MAINTENANCE KIT

Part Number: 201000197

The Waters® Performance Maintenance Kit for the ACQUITY I2V BSM contains all the Waters Quality Parts® necessary to keep your ACQUITY I2V BSM operating at peak performance. The kit also contains a detailed maintenance protocol, including calibration and diagnostic tools to ensure proper installation and function. The Waters® Performance Maintenance Kit for the ACQUITY I2V BSM includes the following parts: tubing (transducer to check vlv), air filter, plungers, flanged seals, wash seals, teflon o-ring, mixer assembly, check valves, solvent bottle filters, I2V cartridge, filter cartridge, and tubing (SSV to I2V). BSMs fitted with the new intelligent intake valve (I2V) began on June 14, 2007 and the cut over serial number is F07UPB573M.

201000197 - ACQUITY I2V BSM PERFORMANCE MAINTENANCE KIT
Part Number: 201000197
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category ACQUITY
Products ACQUITY UPLC I2V Binary Solvent Manager
Replacement Schedule As Needed

info

186003770 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg

Part Number: 186003770

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003770 - XBridge BEH C18 Method Validation Kit, 130Å, 3.5 µm, 4.6 mm X 150 mm, 3/pkg
Part Number: 186003770
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Method Validation Kit
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186007313 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pkg

Part Number: 186007313

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186007313 - XBridge Protein BEH C4 OBD Prep Column, 300Å, 5 µm, 19 mm X 150 mm, 1/pkg
Part Number: 186007313
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
% Carbon Load 8
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format OBD Prep Column
ID 19 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
Surface Area 90
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 1 - 10

info

186006516 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg

Part Number: 186006516

The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186006516 - ACQUITY UPLC Peptide BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 150 mm, 3/pkg
Part Number: 186006516
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Method Validation Kit
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

176003080 - XSelect Peptide CSH C18 Column Kit, Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pkg

Part Number: 176003080

Waters XSelect CSH130 C18 3.5 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. This kit includes three XSelect CSH130 C18 columns packed with three different batches of sorbent and one vial of Cytochrome C Digestion Standard (P/N 186006371). The standard is included to be able to immediately benchmark the column upon receipt and can be reordered as a separate part for continued monitoring. Each batch of digestion standard is prepared under strict quality control criteria confirmed on the included certificate of analysis.

176003080 - XSelect Peptide CSH C18 Column Kit, Method Validation Kit, 130Å, 3.5 µm, 2.1 mm X 100 mm, 3/pkg
Part Number: 176003080
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column Kit
Method Validation Kit
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

WAT050046 - VALVE,SWITCHING,LABPRO

Part Number: WAT050046
WAT050046 - VALVE,SWITCHING,LABPRO
Part Number: WAT050046
Products > Chromatography Consumables & Columns > Accessories

info

WAT080733 - Analytical Flow Cell, 10mm

Part Number: WAT080733

The Analytical Flow Cell Assembly for the 486 detector has a 10mm path length and a pressure limit of 1000psi.

WAT080733 - Analytical Flow Cell, 10mm
Part Number: WAT080733
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 486 Tunable UV/Visible Absorbance Detector

info

WAT057919 - Analytical Cell Assembly, 10mm

Part Number: WAT057919

The Analytical Cell Assembly has a Reverse Taper Beam flow cell design with a 10mm path length and a pressure rating of 1000psi.

WAT057919 - Analytical Cell Assembly, 10mm
Part Number: WAT057919
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Flow Cells
Product Category Detectors
Products 2996 Photodiode Array Detector
996 Photodiode Array Detector