Product Listing:  WAT027324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg   to   WAT010656 - Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Sorted by Popularity
  Product    
info

WAT027324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT027324

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

WAT027324 - µBondapak C18 Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT027324
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 9.8
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT046970

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT046970 - Symmetry C8 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT046970
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186002559

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002559 - SunFire C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186002559
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186001346

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001346 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186001346
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186000404

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000404 - XTerra MS C18 Column, 125Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186000404
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186002033

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002033 - Atlantis Silica HILIC Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186002033
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

WAT011695 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT011695

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT011695 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT011695
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001342 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001342

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001342 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001342
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003748

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003748 - Atlantis T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003748
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg

Part Number: WAT066224

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT066224 - Symmetry C18 Column, 100Å, 3.5 µm, 4.6 mm X 75 mm, 1/pkg
Part Number: WAT066224
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186002553 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002553

SunFire C18 columns are used for general purpose method development at low pH. The C18 ligand is highly retentive, especially for basic compounds and it is ideally suited for purification and impurity profile assays.

186002553 - SunFire C18 Column, 100Å, 3.5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002553
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 16
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 340
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003729 - Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186003729

Atlantis T3 columns are universal, silica-based, reversed-phase C18 columns that provide balanced retention of polar and hydrophobic molecules and should be your first choice when developing separations of polar and non-polar compounds.

186003729 - Atlantis T3 Column, 100Å, 3 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186003729
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 14
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003975

As the premier column for method development, the 1.7 um ACQUITY UPLC BEH C18 sorbent provides you with the most universal column choice for UPLC separations. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), superior low pH stability, and ultra-low column bleed for high sensitivity MS applications. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003975 - ACQUITY UPLC BEH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003975
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186003976

The universal, silica-based bonded phase used for the ACQUITY HSS T3 sorbents is compatible with 100% aqueous mobile phase and should be your first choice when developing separations for polar and non-polar compounds. The ACQUITY HSS T3 UPLC columns exhibit ultra-low MS bleed and are fully scalable and transferable to HPLC separations. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186003976 - ACQUITY UPLC HSS T3 VanGuard Pre-column, 100Å, 1.8 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186003976
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186001344

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001344 - Atlantis dc18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186001344
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001317 - Atlantis dc18 Column, 100Å, 3 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186001317

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001317 - Atlantis dc18 Column, 100Å, 3 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186001317
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

WAT044355 - Carbohydrate Cartridge Column, 4.6 x 250 mm

Part Number: WAT044355

Waters High-Performance Carbohydrate Cartridge Column is packed with 4-μm spherical silica. This column was developed to separate five monosaccharides and disaccharides to give baseline resolution in fewer than 12 minutes. The pre-packed, disposable cartridge column requires reusable end-fittings, which are available separately.

WAT044355 - Carbohydrate Cartridge Column, 4.6 x 250 mm
Part Number: WAT044355
Brand: Carbohydrate

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
USP Classification L8
Units in Package 1/pkg

info

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT052840

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT052840 - Nova-Pak C18 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT052840
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT084040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT084040

If your method calls for µBondapak packings, there is only one µBondapak packing material. Many companies claim to have columns with µBondapak-like selectivity but not one has ever passed Waters stringent QC batch test. Waters set the standard for reproducible, high-performance chromatographic columns. Waters µBondapak columns are still the most widely referenced and requested columns in the world.

WAT084040 - µBondapak Amino (NH2) Column, 125Å, 10 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT084040
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

186001299 - Atlantis dc18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186001299

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001299 - Atlantis dc18 Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186001299
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186001337

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001337 - Atlantis dc18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186001337
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186004786 - XSelect HSS T3 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186004786

The HSS T3 column is a fully endcapped, low-coverage C18 bonded-phase column designed to retain extremely polar compounds by reversed-phase in high aqueous mobile phases.

186004786 - XSelect HSS T3 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186004786
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186003031 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186003031

As a workhorse for HPLC method development, XBridge BEH C18 sorbent can be used over an entire range of mobile phase pH (1-12). The trifunctionally bonded C18 ligand provides you with a universal column for most HPLC separations and gives you the widest usable pH range, superior low pH stability, and ultra-low column bleed.

186003031 - XBridge BEH C18 Column, 130Å, 3.5 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186003031
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186004623

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186004623 - ACQUITY UPLC Protein BEH C4 VanGuard Pre-column, 300Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186004623
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
Application Protein
Chemistry C4
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System UPLC/UHPLC
Technology BEH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 12

info

186003546 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 100 µm X 100 mm, 1/pkg

Part Number: 186003546

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186003546 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 100 µm X 100 mm, 1/pkg
Part Number: 186003546
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format nanoACQUITY Column 10K psi
ID 100 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186003836 - AccQ-Tag Ultra Derivatization Kit

Part Number: 186003836

Amino Acid Analysis (AAA) is required for many applications. AccQ•Tag Ultra Derivitization Kit is a component of the UPLC® Amino Acid Analysis Application Solution. This kit is executed with UV detection and is enough for 250 anaylses.

186003836 - AccQ-Tag Ultra Derivatization Kit
Part Number: 186003836
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Modifiers
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System UPLC

info

WAT052880 - AccQ-Fluor Reagent Kit

Part Number: WAT052880

Amino Acid Analysis (AAA) is required for many applications. AccQ-Tag-Fluor Reagent Pkg Includes: AccQTagFluor Reagent 1, 5X 6mL Vials Reagent 2A 5 X 3 mg vials, AccQFluor Reagent 2B 5 X 4mL vials. The components of this kit are not available separately.

WAT052880 - AccQ-Fluor Reagent Kit
Part Number: WAT052880
Brand: AccQ-Tag

Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid & Solid
Storage Room temp
System HPLC -UV

info

186003607 - XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186003607

The XBridge BEH300 C18 Peptide Separation Technology (PST) columns are optimized and QC tested for peptide separations. The wide-pore (300Å) trifunctionally bonded BEH particle offers you the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

186003607 - XBridge Peptide BEH C18 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186003607
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Peptide Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

WAT086344 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT086344

Nova-Pak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT086344 - Nova-Pak C18 Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT086344
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 7.3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT010656 - Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT010656

Nova-Pak HP Phenyl columns are based on 4 µm silica-based particle technology. The phenyl ligand is used to achieve unique compound selectivity with reversed-phase applications.

WAT010656 - Nova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT010656
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4.6
Chemistry Phenyl
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L11
Units in Package 1/pkg
pH Range 2 - 8