Product Listing:  186005125 - Oasis HLB Plus Light Cartridge, 30 mg Sorbent per Cartridge, 30 µm Particle Size, 50/pk   to   WAT084199 - PIC B6 Low UV Reagent

Sorted by Popularity
  Product    
info

186005125 - Oasis HLB Plus Light Cartridge, 30 mg Sorbent per Cartridge, 30 µm Particle Size, 50/pk

Part Number: 186005125

Oasis HLB sample extraction products contain a polymeric water-wettable reversed-phase sorbent. When combined with a simple, generic methodology, HLB sorbent allows the extraction of a wide range of compounds in various matrices with high reproducible recoveries.

186005125 - Oasis HLB Plus Light Cartridge, 30 mg Sorbent per Cartridge, 30 µm Particle Size, 50/pk
Part Number: 186005125
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry HLB
Format/Type Plus Light Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Sorbent Weight 30 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

700004219 - Sample Cone

Part Number: 700004219

This spare part is a Waters Quality part.

700004219 - Sample Cone
Part Number: 700004219
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Xevo™ TQ MS
Replacement Schedule As Needed

info

WAT054515 - Sep-Pak Aminopropyl (NH2) 20 cc Vac RC Cartridge, 500 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk

Part Number: WAT054515

Sep-Pak Amino Propyl (NH2) Vac RC cartridges contain a moderately polar, silica-based bonded phase with weakly basic surface. The sorbent can be used as a polar sorbent with different selectivity for acidic/basic analytes or as a weak anion exchanges in aqueous medium below pH 8. Applications include extraction of phenols and phenolic pigments, petroleum fractionation, saccharides and drugs and metabolites. These cartridges feature an integral 20 cc funnel-shaped reservoir for convenient processing of larger volumes of samples. They can be used with robotic sample preparation equipment or with vacuum manifolds.

WAT054515 - Sep-Pak Aminopropyl (NH2) 20 cc Vac RC Cartridge, 500 mg Sorbent per Cartridge, 55-105 µm Particle Size, 50/pk
Part Number: WAT054515
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 20 cc
Chemistry Aminopropyl (NH2)
Endcap End Capped
Format/Type Vac RC Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 500 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT271082 - Solvent Bottle Tray

Part Number: WAT271082

The Solvent Bottle Tray holds four 1-Liter bottles. The solvents should be placed above the gradient proportioning valve.

WAT271082 - Solvent Bottle Tray
Part Number: WAT271082
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module

info

186004540 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 46 mg Sorbent per Cartridge, 40 µm Particle Size, 50/pk

Part Number: 186004540

Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride counter-ion in the standard Sep-Pak Accell Plus QMA cartridges interferes with the analysis. These Light-style cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.

186004540 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 46 mg Sorbent per Cartridge, 40 µm Particle Size, 50/pk
Part Number: 186004540
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA Carbonate
Format/Type Plus Light Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 40 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 46 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 2 - 8 pH

info

186003069 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 3 mm X 20 mm, 2/pkg

Part Number: 186003069

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003069 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 3 mm X 20 mm, 2/pkg
Part Number: 186003069
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 3 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 11

info

186003070 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pkg

Part Number: 186003070

XBridge BEH Shield RP18 columns complement the XBridge BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.

186003070 - XBridge BEH Shield RP18 Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pkg
Part Number: 186003070
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 4.6 mm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System HPLC
Technology BEH
USP Classification L1
Units in Package 2/pkg
pH Range 2 - 11

info

WAT027060 - Porapak Q 80-100 mesh, 26 grams

Part Number: WAT027060

Porapak GC column packing materials simplify the analysis of a wide variety of complex compounds from atmospheric gases to organics.

WAT027060 - Porapak Q 80-100 mesh, 26 grams
Part Number: WAT027060
Products > Chromatography Consumables & Columns > Accessories > Gas Chromatography Packings
Category All Gas Packings

info

186004051 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: 186004051

Sep-Pak Accell Plus QMA Carbonate Plus Light cartridges contain a silica-based, hydrophilic, strong anion-exchanger with a large pore size (300Å) and a carbonate counter-ion. These cartridges are used for extraction of anionic analytes in aqueous and non-aqueous solutions when the chloride counter-ion in the standard Sep-Pak Accell Plus QMA cartridges interferes with the analysis. These Light-style cartridges have a distinctive finned outer body and a reduced internal diameter, which results in an interstitial volume about one-third that of the corresponding Plus-style cartridge. This design allows you to elute fractions in a minimal volume to improve recoveries and reduce solvent consumption, a benefit especially for applications where samples are limited or where excessive dilution is a concern.

186004051 - Sep-Pak Accell Plus QMA Carbonate Plus Light Cartridge, 130 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: 186004051
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA Carbonate
Format/Type Plus Light Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 130 mg
Units In Package 50/pkg
Water Wettable Water Wettable
pH Range 2 - 8 pH

info

700004206 - Capillary Tube

Part Number: 700004206

This spare part is a Waters Quality part.

700004206 - Capillary Tube
Part Number: 700004206
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
Xevo Q-Tof Mass Spec
Xevo™ TQ MS
Replacement Schedule As Needed

info

WAT079731 - FEP/Tygon Tubing, 50ft.

Part Number: WAT079731

One end of the FEP-lined Tygon Tubing attaches to the vent fitting at the back of the in-line degasser. Place the other end of the tubing in a waste container in the venting outlet. The container catches any incidental leaks or condensates from the in-line degasser.

WAT079731 - FEP/Tygon Tubing, 50ft.
Part Number: WAT079731
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Electrical
Product Category Systems Components
Products In-Line Degasser

info

WAT010835 - Sep-Pak Accell Plus QMA Classic Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT010835

Sep-Pak Accell Plus QMA Classic cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These Classic-style cartridges are designed for use with positive displacement by a Luer-tip syringe and can also attach easily to vacuum-assisted flow devices using a male/male adaptor.

WAT010835 - Sep-Pak Accell Plus QMA Classic Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT010835
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA
Format/Type Classic Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT027059 - Porapak Q 50-80 mesh, 26 grams

Part Number: WAT027059

Porapak GC column packing materials simplify the analysis of a wide variety of complex compounds from atmospheric gases to organics.

WAT027059 - Porapak Q 50-80 mesh, 26 grams
Part Number: WAT027059
Products > Chromatography Consumables & Columns > Accessories > Gas Chromatography Packings
Category All Gas Packings

info

WAT027048 - Porapak N 80-100 mesh, 29 grams

Part Number: WAT027048

Porapak GC column packing materials simplify the analysis of a wide variety of complex compounds from atmospheric gases to organics.

WAT027048 - Porapak N 80-100 mesh, 29 grams
Part Number: WAT027048
Products > Chromatography Consumables & Columns > Accessories
Category All Gas Packings

info

700003055 - Sample Cone 0.5 Diam.

Part Number: 700003055

This spare part is a Waters Quality part.

700003055 - Sample Cone 0.5 Diam.
Part Number: 700003055
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products 3100 Mass Detector
Single Quad Detector
Tandem Quadrupole Detector
Replacement Schedule As Needed

info

WAT020545 - Sep-Pak Accell Plus QMA Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk

Part Number: WAT020545

Sep-Pak Accell Plus QMA Plus Short cartridges contain a silica-based, hydrophilic, strong anion-exchanger with large pore size (300Å). The cartridges are designed for extraction of anionic analytes in aqueous and non-aqueous solutions. The large pore size makes it ideal for isolation of larger molecules such as anionic proteins such as immunoglobulins and enzymes. Other applications include isolation of phenolic compounds and removal of acidic pigments in wine, fruit juices, and food extracts. These versatile cartridges can attach easily to pumps and syringes for reliable, positive-pressure flow to speed up the sample processing time. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.

WAT020545 - Sep-Pak Accell Plus QMA Plus Short Cartridge, 360 mg Sorbent per Cartridge, 37-55 µm Particle Size, 50/pk
Part Number: WAT020545
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Accell Plus QMA
Format/Type Plus Short Cartridge
Ion Exch. Capacity 230 µeq/gram
Mass Spec Compatibility Mass Spec Compatible
Mode Ion-exchange
Particle Size 37-55 µm
Pore Size 300Å
Sorbent Substrate Silica
Sorbent Weight 360 mg
Units In Package 50/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

WAT027078 - Porapak T 80-100 mesh, 31 grams

Part Number: WAT027078

Porapak GC column packing materials simplify the analysis of a wide variety of complex compounds from atmospheric gases to organics.

WAT027078 - Porapak T 80-100 mesh, 31 grams
Part Number: WAT027078
Products > Chromatography Consumables & Columns > Accessories > Gas Chromatography Packings
Category All Gas Packings

info

186000632 - XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pkg

Part Number: 186000632

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000632 - XTerra MS C18 Sentry Guard Cartridge, 125Å, 3.5 µm, 2.1 mm X 10 mm, 2/pkg
Part Number: 186000632
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Format Sentry Guard Cartridge
ID 2.1 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 2/pkg
pH Range 1 - 12

info

WAT043345 - Sep-Pak C18 35 cc Vac Cartridge, 10 g Sorbent per Cartridge, 55-105 µm Particle Size, 10/pk

Part Number: WAT043345

Silica-based bonded phase with strong hydrophobicity; used to adsorb analytes of even weak hydrophobicity from aqueous solutions; typical applications include drugs and their metabolites in serum, plasma or urine, desalting of peptides, trace organics in environmental water samples, organic acids in beverages; similar in behavior to reversed-phase HPLC columns.

WAT043345 - Sep-Pak C18 35 cc Vac Cartridge, 10 g Sorbent per Cartridge, 55-105 µm Particle Size, 10/pk
Part Number: WAT043345
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Barrel Size 35 cc
Chemistry C18
Endcap End Capped
Format/Type Vac Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Reversed-phase
Particle Size 55-105 µm
Pore Size 125Å
Sorbent Substrate Silica
Sorbent Weight 10 g
Units In Package 10/pkg
Water Wettable Not Water Wettable
pH Range 2 - 8 pH

info

186006841 - 2-AB Dextran Calibration Ladder

Part Number: 186006841

In order to take full advantage of the BEH glycan column, Waters created the 2-aminobenzamide labeled 2-AB Dextran Calibration Ladder Standard to assist glycan profiling. Glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the 2AB-labeled dextran ladder and assigned with glucose unit (GU) values. Waters 2-AB labeled Dextran Calibration Ladder is different than the existing commercial offerings. The average molecular weight of the glucose homopolymer is higher (~4,500 Dalton), therefore, the workable GU value range is twice as much as the other dextran ladder standards; the observed GU goes from 2 to 30. This feature improves the large glycan retention time assignment.

186006841 - 2-AB Dextran Calibration Ladder
Part Number: 186006841
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Packaging 1/pkg
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

PSS830077 - Spherisorb Cyano (CN) Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pkg

Part Number: PSS830077

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of 6.2%.

PSS830077 - Spherisorb Cyano (CN) Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pkg
Part Number: PSS830077
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 3.1
Chemistry Cyano (CN)
Endcapped No
Format Guard Cartridge
ID 4.6 mm
Length (mm) 10 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L10
Units in Package 3/pkg
pH Range 2 - 8

info

WAT084283 - PIC B8 Low UV Reagent

Part Number: WAT084283

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B8 low UV is a 5 vial/pkg of octane sulfonic acid in a workable UV range in mobile phase 200+ nm.

WAT084283 - PIC B8 Low UV Reagent
Part Number: WAT084283
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV

info

405011492 - Needle Seat

Part Number: 405011492

The needle seat is a spare part used on the ACQUITY H-Class Sample Manager-FTN and the ACQUITY I-Class Sm-FTN. The original part number was 405008397 and the new replacement part number is 405011492.

405011492 - Needle Seat
Part Number: 405011492
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Products ACQUITY H-Class Sample Manager-Flow Through Needle
ACQUITY I-Class SM-FTN
Replacement Schedule As Needed

info

WAT026014 - Outlet Check Valve Rebuild Kit (225µL)

Part Number: WAT026014

Assemble and replace valves yourself at significant cost savings with this easy-to-use kit. Although ball and seat outlet check valves are also available pre-assembled, the rebuild kit gives you the option of self-maintenance at significant cost savings. The Ball and Seat Outlet Check Valve Rebuild Kit contains the ball and seat cartridge, gaskets, and comprehensive instructions. The valve should be replaced every 12 months.

WAT026014 - Outlet Check Valve Rebuild Kit (225µL)
Part Number: WAT026014
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category Pumps
Systems
Products 510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump
LC Module 1

info

WAT270940 - Wash Tube Seal Replacement Kit, 4/Pkg

Part Number: WAT270940

These seals are integral to the solvent management system of your 2690 and 2790 Separations Modules. As part of the seal wash system, they help ensure that plunger seal life is maximized.

WAT270940 - Wash Tube Seal Replacement Kit, 4/Pkg
Part Number: WAT270940
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Seals
Product Category Separations Module
Systems
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module

info

186006348 - 20 Pesticide Mix Standard

Part Number: 186006348

10ug/mL of each: atrazin, atrazin-desethyl, cyanazin, sebuthylazin, simazin, terbuthylazin, hexazinone, chlortoluron, diuron, linuron, metobromuron, metoxuron, monolinuron, metolachlor, Methamidophos, Acephate, Methomyl, Dicrotophos, Buprofenzin, Fenpropimorph in Acetonitrile

186006348 - 20 Pesticide Mix Standard
Part Number: 186006348
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Environment
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Refrigerator 2 to 8 C
System LC/MS

info

PSS830073 - Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pkg

Part Number: PSS830073

Spherisorb ODS1 columns are general purpose, silica-based, reversed-phase C18 columns. The ODS1 packing features low ligand density with a specified carbon load of ?6.2%.

PSS830073 - Spherisorb ODS1 Guard Cartridge, 80Å, 5 µm, 4.6 mm X 10 mm, 3/pkg
Part Number: PSS830073
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 6.2
Bonding Technology ODS1
Chemistry C18
Endcapped No
Format Guard Cartridge
ID 4.6 mm
Length (mm) 10 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 80Å
Silanol Activity High
Surface Area 220
System HPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red

Part Number: 6436005-S10

This spare part is a Waters Quality part.

6436005-S10 - Tube PEEK 1/16in x .005in, 10m Red
Part Number: 6436005-S10
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category Mass Spectrometry
Products LCT Premier
Q-Tof micro Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Synapt High Definition MS System™
Replacement Schedule As Needed

info

WAT054265 - Sep-Pak Dry Sodium Sulfate, Plus Long Cartridge, 2.85 g Particle Size, 50/pkg

Part Number: WAT054265

Waters Sep-Pak Dry cartridges are packed with 2.85g of anhydrous sodium sulfate. These cartridges are designed to remove residual water from the SPE extract.

WAT054265 - Sep-Pak Dry Sodium Sulfate, Plus Long Cartridge, 2.85 g Particle Size, 50/pkg
Part Number: WAT054265
Brand: Sep-Pak

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Sodium Sulfate
Format/Type Plus Long Cartridge
Mass Spec Compatibility Mass Spec Compatible
Mode Application Specific
Sorbent Substrate Sodium Sulfate
Sorbent Weight 2.85 g
Units In Package 50/pkg
Water Wettable Not Water Wettable

info

WAT084199 - PIC B6 Low UV Reagent

Part Number: WAT084199

Paired -Ion Chromatography (PIC® Reagents) provide an easy solution for analyzing samples containing ionic species. These reagents allow ionic compounds to be separated by reverse-phase chromatography, saving time by allowing simultaneous assay of acids, bases, amphoteric and neutral compounds. PIC B6 Low UV is a 5 vial/pkg of hexane sulfonic acid in a workable UV range in mobile phase 200+ nm.

WAT084199 - PIC B6 Low UV Reagent
Part Number: WAT084199
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Life Science
Detector UV
Product Type Reagent
Shipping Formulation Liquid
Storage Room temp
System HPLC -UV