Product Listing:  186007496 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg   to   WAT088070 - µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pkg

Sorted by Popularity
  Product    
info

186007496 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg

Part Number: 186007496

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007496 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/M, 1/pkg
Part Number: 186007496
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Trap Column
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System Nano/Micro
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT007356 - IC-Pak Cation Guard Column, 10 µm, 4.6 x 50 mm

Part Number: WAT007356

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT007356 - IC-Pak Cation Guard Column, 10 µm, 4.6 x 50 mm
Part Number: WAT007356
Brand: IC-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Guard Column
ID 4.6 mm
Length (mm) 50 mm
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 1/pkg

info

186007497 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg

Part Number: 186007497

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007497 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg
Part Number: 186007497
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Trap Column
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System Nano/Micro
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info 186007238 - nanoACQUITY UPLC Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2D, V/M, 1/pkg
Part Number: 186007238
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
Chemistry C18
Format nanoACQUITY Trap 10K psi MV
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Pore Size 100Å
Silanol Activity Low
System Nano/Micro
Units in Package 1/pkg
pH Range 1 - 10

info

186007500 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/V, 1/pkg

Part Number: 186007500

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007500 - ACQUITY UPLC M-Class Symmetry C18 Trap Column, 100Å, 5 µm, 180 µm x 20 mm, 2G, V/V, 1/pkg
Part Number: 186007500
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Chemistry C18
Endcapped Yes
Format Trap Column
ID 180 µm
Length (mm) 20 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System Nano/Micro
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

700008893 - ToF G2-S Standard Ki Kit - 3

Part Number: 700008893

Standards Kit for the verification of system performance for Tof G2-S Contains: Standard 1: 2 vials of 2.5 mg D(+)-Raffinose, Standard 2: 5 vials of 10 mg Matrix (? - Cyano-4-hydroxycinnamic acid), Standard 3 2 mL of formic Acid, Standard 4: 3 mL Aqueous Ammonia

700008893 - ToF G2-S Standard Ki Kit - 3
Part Number: 700008893
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Refrigerator 2 to 8 C
System LC/MS

info

176001676 - DisQuE Quechers, AOAC Method Sample Preparation Kit, Tubes

Part Number: 176001676

DisQuE Dispersive Sample Preparation used for QUECHERS Method AOAC Method 2007.01. The kit consists of 100 units each of extraction tubes and clean-up tubes. Each 50 mL DisQuE Extraction tube contains 6 grams of magnesium sulphate and 1.5 grams of sodium acetate. Each 2 mL DisQuE Clean-Up tube contains 150 mg of magnesium sulphate and 50 mg PSA (primary-secondary amine SPE sorbent). Detailed method instructions are included with the kit. QUECHERS (pronounced catchers) methods are used for multi-pesticide residue analyses in food.

176001676 - DisQuE Quechers, AOAC Method Sample Preparation Kit, Tubes
Part Number: 176001676
Brand: DisQuE

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Dispersive
Mass Spec Compatibility Mass Spec Compatible
Units In Package 100/pkg

info

WAT044250 - IC-Pak Cation M/D Guard Pak Inserts, 10/pk

Part Number: WAT044250

Waters offers an array of products for ion chromatography . IC-Pak resin based columns allow you to analyze a full range of ions from numerous sample matrices, both simple and complex. They offer an exceptional linear loading range of less than 1.0 ppb to greater than 400 ppm without dilution and without pH limitation on eluent or sample. The flexibility exists for accurate and reproducible anion and cation analyses at all concentration levels.

WAT044250 - IC-Pak Cation M/D Guard Pak Inserts, 10/pk
Part Number: WAT044250
Brand: IC-Pak M/D

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Cation-exchange
Format Guard-Pak Insert
Mode Ion-Exchange
Particle Size (dp) 10 µm
Units in Package 10/pkg

info

405007627 - Plunger Removal Tool

Part Number: 405007627

ACQUITY BSM Plunger Removal Tool

405007627 - Plunger Removal Tool
Part Number: 405007627
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tools
Product Category ACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
ACQUITY I-Class BSM
Replacement Schedule As Needed

info

WAT025874 - Porasil Silica Column, 125Å, 15-20 µm, 3.9 mm X 300 mm, 1/pkg

Part Number: WAT025874

Waters Porasil 15 - 20µm silica packing material provides long column life and low backpressure. The packing also has a high surface area making it ideal for preparative work.

WAT025874 - Porasil Silica Column, 125Å, 15-20 µm, 3.9 mm X 300 mm, 1/pkg
Part Number: WAT025874
Brand: Porasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 300 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 15-20 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

WAT035877 - Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg

Part Number: WAT035877

Nova-Pak C8 columns are general purpose, silica-based, reversed-phase C8 columns that are based on 4 µm particle technology. Compared to a 5 µm column, Nova-Pak columns offer higher resolution, more efficient separations, and faster chromatography.

WAT035877 - Nova-Pak C8 Column, 60Å, 4 µm, 3.9 mm X 75 mm, 1/pkg
Part Number: WAT035877
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 75 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

700001594 - MS Set Up Solution, Atmospheric Pressure Ionization

Part Number: 700001594

Standard used for Mass Spec Set up. 2ng/ul Reserpine, 25ng/ul PPG 1000 50ng/ul Triacetyl-B-Cyclodextrin in 50/50 Acetonitrile/Water with 4mM Ammonium Acetate 15mL Nalgene Bottle

700001594 - MS Set Up Solution, Atmospheric Pressure Ionization
Part Number: 700001594
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

700003563 - Assy., Cartridge, Intelligent Vlv, 2/pkg

Part Number: 700003563

This cartridge assembly is part of the Intelligent Intake Vale found on the ACQUITY Binary Solvent Manager.

700003563 - Assy., Cartridge, Intelligent Vlv, 2/pkg
Part Number: 700003563
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category ACQUITY
Products ACQUITY I-Class BSM
ACQUITY UPLC I2V Binary Solvent Manager
Replacement Schedule As Needed

info

WAT270926 - Seal Wash Pump Solenoid

Part Number: WAT270926

This spare part is a Waters Quality part.

WAT270926 - Seal Wash Pump Solenoid
Part Number: WAT270926
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
ACQUITY H-Class Quaternary Solvent Manager
Replacement Schedule As Needed

info

186002643 - 96-well Sample Collection Plate, Round well, Polypropylene 350µL 100/pkg

Part Number: 186002643

Waters offers a selection of 96-and 384-well sample/collection plates along with cap mats and heat seals.

186002643 - 96-well Sample Collection Plate, Round well, Polypropylene 350µL 100/pkg
Part Number: 186002643
Products > Chromatography Consumables & Columns > Vials, Plates, and Certified Containers
Auto Sampler Waters 2795
Waters Acquity
Certified Not Certified
Format 96 Well Plates
Units in Package 100/pkg
Volume Capacity 350 µL

info

700004216 - Cone Gas Nozzle

Part Number: 700004216

This spare part is a Waters Quality part.

700004216 - Cone Gas Nozzle
Part Number: 700004216
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2 HDMS System
SYNAPT G2 MS System
SPECVALUE134881948
Xevo Q-Tof Mass Spec
Replacement Schedule As Needed

info

700003105 - SQD Set Up Solution

Part Number: 700003105

Mass Spectrometry (SQD) standards kit for system assessment. 1 x 10ml Set-up Solution QP: PPG 1000 2.5 ng/ul, Triacetyl-B-cyclodextrin 5.0 ng/ul, verapamil 100.0 pg/ul, ammonium acetate 0.31 mg/ml, Leucine Enkaphalin 1 ng/ul all in Acetonitrile/Water(1:1v/v)in brown Nalgene bottle Certificate of Analysis

700003105 - SQD Set Up Solution
Part Number: 700003105
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Room temp
System LC/MS

info

700005350 - Sample Cone - 0.8mm

Part Number: 700005350

This spare part is a genuine Waters Quality Part

700005350 - Sample Cone - 0.8mm
Part Number: 700005350
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SYNAPT G2 MS System
Xevo TQ-S MS
Replacement Schedule As Needed

info

430002242 - Tubing, Capillary w/ Frit 25µ x 18in.

Part Number: 430002242

This Capillary Tubing connects the BSM to the inject valve of the nanoACQUITY UPLC in the Direct Injection Configuration and the Single Pump Trapping Configuration. It also connects the Trap Valve with the MM union on the nanoACQUITY UPLC in the Dual Pump Trapping Configuration and the 2D Configuration. To see the Fluidic Configurations for the nanoACQUITY UPLC, go to the Url Link below, under Systems select nanoACQUITY, click on the Waters Graphical Part Locator, and then choose Fluidic Configurations on the right side of the page. There will be the six different configurations of the nanoACQUITY that you can click on individually to see a larger image. There will also be a parts list for that specific configuration on the right side of the page. This part number was originally p/n 430001564and then was changed to the new part number, p/n 430002242.

430002242 - Tubing, Capillary w/ Frit 25µ x 18in.
Part Number: 430002242
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Tube Assembly (specified)
Product Category nanoACQUITY
Products High Pressure nanoACQUITY UPLC Sample Manager
nanoACQUITY UPLC with 2D Technology
Replacement Schedule As Needed

info

700001237 - ZQ/ Quattro Micro Sample Cone

Part Number: 700001237

This spare part is a Waters Quality part.

700001237 - ZQ/ Quattro Micro Sample Cone
Part Number: 700001237
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products EMD 1000 Mass Spectrometer
Quattro micro Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule No
sparepartsystemscategory LCMS

info

186002051 - Oasis MCX 2.1 X 20 mm Online Cartridge Column, 30 µm Particle Size, 1/pk

Part Number: 186002051

The Oasis MCX on-line cartridge column is designed for rugged, reproducible, and ultra-fast on-line SPE. This cartridge column contains the Oasis MCX sorbent, which is a novel, mixed-mode polymeric sorbent that has been optimized to achieve higher selectivity and sensitivity for extracting basic compounds with cation-exchange groups. This on-line cartridge column is designed to be used with the appropriate Waters narrow-bore analytical column, such as XSelect, XBridge, SunFire, Atlantis, XTerra, or Symmetry column. The Oasis MCX on-line cartridge column fits into a Sentry holder that features a finger-tight fitting for fast, convenient replacement.

186002051 - Oasis MCX 2.1 X 20 mm Online Cartridge Column, 30 µm Particle Size, 1/pk
Part Number: 186002051
Brand: Oasis

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry MCX
Format/Type Online Cartridge Column
Ion Exch. Capacity 1 meq/gram
Length 20 mm
Mass Spec Compatibility Mass Spec Compatible
Mode Mixed mode
Particle Size 30 µm
Pore Size 80Å
Sorbent Substrate Copolymer
Units In Package 1/pkg
Water Wettable Water Wettable
pH Range 0 - 14 pH

info

700009087 - Sample Cone, Xevo G2 (-S/XS)

Part Number: 700009087

Sample Cone, aperture diameter 0.67mm, St. Stl.

700009087 - Sample Cone, Xevo G2 (-S/XS)
Part Number: 700009087
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products SPECVALUE134881948
Xevo G2-S
Replacement Schedule As Needed

info

WAT010740 - AccellPlus CM 100 G

Part Number: WAT010740

Accell Plus ion exchange packings are 40µm, 300 angstrom polymer-coated silica-based materials and are available in strong anion and weak cation exchangers. These packings, for all preparative isolations based on ionic interactions, particularly proteins, enzymes and immunoglobulins and be packed into our Advanced Purification (AP) glass columns.

WAT010740 - AccellPlus CM 100 G
Part Number: WAT010740
Brand: AccellPlus

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > AccellPlus Ion Exchange Packings
Application Protein
Chemistry Cation-exchange
Format Bulk 100gm
Mode Ion-Exchange
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 40 µm
Particle Substrate Silica
Pore Size 300Å
Units in Package 1/pkg
pH Range 2 - 9

info

WAT022384 - 1/16in. OD S.S. Tubing Cutter w/3 Blades

Part Number: WAT022384

The tubing cutter scores the outer diameter of 1/16 inch OD stainless steel tubing, making it easier to break apart the tubing. A straight, clean cut is of utmost importance when cutting stainless steel tubing. If the tubing is jagged or bent, it makes it difficult to fit the ferrule onto the tubing and will result in either bandspreading or dead volume.

WAT022384 - 1/16in. OD S.S. Tubing Cutter w/3 Blades
Part Number: WAT022384
Products > Chromatography Consumables & Columns > Accessories > Tubing

The tubing cutter scores the outer diameter of 1/16 inch OD stainless steel tubing, making it easier to break apart the tubing. A straight, clean cut is of utmost importance when cutting stainless steel tubing. If the tubing is jagged or bent, it makes it difficult to fit the ferrule onto the tubing and will result in either bandspreading or dead volume.

info

WAT271019 - Seal Pack Rebuild Kit w/Needle

Part Number: WAT271019

The Seal Pack Rebuild Kit includes all of the parts necessary to replace seals in the seal body, including the high pressure seals. Replacement of these seals requires use of HPMV Tool Kit (WAT045427). The Rebuild Kit includes: one Teflon washer, one needlewash filter, one upper spacer, one lower spacer, one alignment tube, one wash tube seal, one needle, two high pressure seals, one compression screw, and one ferrule.

WAT271019 - Seal Pack Rebuild Kit w/Needle
Part Number: WAT271019
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Separations Module
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module

info

700000337 - ESI Probe Tip Assy

Part Number: 700000337

This spare part is a Waters Quality part.

700000337 - ESI Probe Tip Assy
Part Number: 700000337
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Mass Spectrometry
Products 3100 Mass Detector
EMD 1000 Mass Spectrometer
LCT Mass Spectrometer
LCT Premier
LCT Premier XE
Q-Tof II Mass Spectrometer
Q-Tof 1 Mass Spectrometer
Q-Tof API US Mass Spectrometer
Q-Tof Premier Mass Spectrometer
Q-Tof Ultima API Mass Spectrometer
Q-Tof Ultima Global Mass Spectrometer
Q-Tof Ultima MALDI Mass Spectrometer
Q-Tof micro Mass Spectrometer
Quattro LC Mass Spectrometer
Quattro Premier Mass Spectrometer
Quattro Premier XE Mass Spectrometer
Quattro Ultima Mass Spectrometer
Quattro Ultima PT Mass Spectrometer
Quattro micro Mass Spectrometer
SYNAPT™ MS
Single Quad Detector
Synapt High Definition MS System™
Tandem Quadrupole Detector
ZMD Mass Spectrometer
ZQ Mass Spectrometer
Replacement Schedule As Needed

info

700002596 - UPLC Primary Check Valve Assy., 2/pkg

Part Number: 700002596

The UPLC Primary Check Valve fits into the ACQUITY UPLC ACQUITY I-Class and the nanoACQUITY UPLC. The original part number was 700002704 and it was changed to p/n 700002596. This is a spring-loaded check valve.

700002596 - UPLC Primary Check Valve Assy., 2/pkg
Part Number: 700002596
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Check Valves
Product Category ACQUITY
nanoACQUITY
Products ACQUITY I-Class BSM
ACQUITY UPLC Binary Solvent Manager
High Pressure nanoACQUITY UPLC Binary Solvent Manager/Auxillary Solvent Manager
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
Replacement Schedule As Needed

info

186004835 - Graphitized Carbon Black, 25g Bottle

Part Number: 186004835

Graphitized carbon black effectively removes pigments and can be added to the clean-up tube with PSA and MgSO4 during the d-SPE cleanup step.

186004835 - Graphitized Carbon Black, 25g Bottle
Part Number: 186004835
Brand: DisQuE

Products > Chromatography Consumables & Columns > Sample Preparation Products
Chemistry Dispersive
Mass Spec Compatibility Mass Spec Compatible
Units In Package 1/pkg

info

700008842 - TOF G2-S Sample Kit -1

Part Number: 700008842

Standards Kit for the verification of system performance for Tof G2-S Contains: Standard 1: 2 vials of 3 mg Leucine Enkephalin, Standard 2: 2 vials of 0.1 mg [Glu1]-Fibrinopeptide B, Standard 3: 1 vial of 1 nmole MassPREP™ Digestion Standard, Alcohol Dehydrogenase, Standard 4: 1 vial of 1 nmole MassPREP™ Digestion Standard, Enolase

700008842 - TOF G2-S Sample Kit -1
Part Number: 700008842
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid & Solid
Storage Frozen -20 C
System LC/MS

info

WAT088070 - µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pkg

Part Number: WAT088070

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

WAT088070 - µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pkg
Part Number: WAT088070
Brand: µBondapak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Format Guard-Pak Insert
Mode Reversed-Phase
Particle Size (dp) 10 µm
Pore Size 125Å
Units in Package 10/pkg