Product Listing:  700001218 - PerformancePLUS Vacuum Chamber   to   700003276 - Q-Tof Qualification Standards Kit

Sorted by Popularity
  Product    
info

700001218 - PerformancePLUS Vacuum Chamber

Part Number: 700001218

The PerformancePLUS Vacuum Chamber is a low volume (500µL internal volume) chamber used on the 2790/2795, 2690/2695 Separations Modules, and the stand-alone Vacuum Degasser. It uses a Teflon AF Membrane which allows for a lower internal volume and equivalent degassing efficiency, resulting in easier system priming and faster solvent changeover.

700001218 - PerformancePLUS Vacuum Chamber
Part Number: 700001218
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Separations Module
Systems Components
Products 2690 Separations Module
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
2796 Bioseparations Module
In-Line Degasser

info

186004775 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004775

The HSS C18 is a general-purpose C18 bonded phase column that provides superior peak shape for bases, increased retention (vs. XBridge C18 columns), and exceptional column lifetimes at low pH. The selectivity and retention observed with HSS C18 columns will resemble that of most modern, fully endcapped, high-coverage silica-based C18 columns.

186004775 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004775
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

186002430 - BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002430

BioSuite™ Peptide Analysis columns consist of two premier reversed-phase column chemistries specifically optimized for peptide mapping from simple to complicated digests. BioSuite PA Columns are available in various configurations for LC or LC/MS applications, including 250 mm lengths for ultra high resolution. These BioSuite™ PA-A and PA-B columns provide excellent batch-to-batch reproducibility for consistent results and are uniquely QC tested specifically for peptide mapping. BioSuite™ C18 3µm PA-A is a100Å, difunctional bonded, low ligand density, silica-based reverse-phase column and BioSuite™ C18 3.5µm PA-B is a 300Å, high ligand density, monofunctional, silica-based reverse-phase column.

186002430 - BioSuite C18 Column, 100Å, 3 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002430
Brand: BioSuite

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > BioSuite Columns
Application Peptide
Chemistry C18
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT058931 - Polystyrene ReadyCal Standards 2 mL Kit

Part Number: WAT058931

Thirty autosample vials which contain 4 polystyrene standards per vial. There are three separate molecular weight ranfes in each kit, 10 units of each of the three molecular weight standards. Just add solvent to the vial, let it stand 2 hours, shake gently and load into you autosampler for analysis. Each kit comes with detailed instructions for proper usage. Mw Part [Da]* / PDI 560* / < 1.50 : 1200 / < 1.50 : 3200 / < 1.15 : 8000 / < 1.15 : 18000 / < 1.15 : 33000 / < 1.15 : 62000 / < 1.15 : 120000 / < 1.15 : 280000 / < 1.15 : 560000 / < 1.15 : 1200000 / < 1.50 : 2500000 / < 1.50

WAT058931 - Polystyrene ReadyCal Standards 2 mL Kit
Part Number: WAT058931
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Chemical
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

700001483 - Rotor Seal, Vent Valve

Part Number: 700001483

This spare part is a Waters Quality part

700001483 - Rotor Seal, Vent Valve
Part Number: 700001483
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Rotors/stators
Product Category Pumps
Products 2545 Binary Gradient Module
2555 Quaternary Gradient Module
Replacement Schedule As Needed

info

186004793 - XSelect HSS T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004793

The HSS T3 column is a fully endcapped, low-coverage C18 bonded-phase column designed to retain extremely polar compounds by reversed-phase in high aqueous mobile phases.

186004793 - XSelect HSS T3 Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004793
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT037836 - µPorasil Silica Radial-Pak Guard, 125Å, 10 µm, 40 mm X 10 mm, 2/pkg

Part Number: WAT037836

Waters µPorasil 10µm silica packing material provides high-efficiency and low backpressure.

WAT037836 - µPorasil Silica Radial-Pak Guard, 125Å, 10 µm, 40 mm X 10 mm, 2/pkg
Part Number: WAT037836
Brand: µPorasil

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Format Radial-Pak Guard
ID 40 mm
Length (mm) 10 mm
Mode Normal-Phase
Particle Shape Irregular
Particle Size (dp) 10 µm
Particle Substrate Silica
Pore Size 125Å
Silanol Activity High
Surface Area 330
USP Classification L3
Units in Package 2/pkg
pH Range 2 - 8

info

201000102 - REAGENT MANAGER PERFORMANCE MAINTENACE KIT

Part Number: 201000102

The Waters® Performance Maintenance Kit for the Reagent Manager contains all the Waters Quality Parts® necessary to keep your Reagent Manager operating at peak performance on an annual basis. The Waters® Performance Maintenance Kit includes the following parts: Piston Seal Kit, Seal Flush Diaphragm, two filters, two Filter elements, four Check Valve Capsules and two 2µm Inline Filters.

201000102 - REAGENT MANAGER PERFORMANCE MAINTENACE KIT
Part Number: 201000102
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Pumps
Products Reagent Manager
Replacement Schedule Annually

info

WAT097963 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.2 µm, Aqueous, 300/case

Part Number: WAT097963

GHP has the broadest chemical compatibility and exhibits minimal protein binding

WAT097963 - Acrodisc, Minispike Syringe Filter, GHP, 13 mm, 0.2 µm, Aqueous, 300/case
Part Number: WAT097963
Brand: Acrodisc

Products > Chromatography Consumables & Columns > Laboratory Filters
Diameter 13 mm
Format Minispike Syringe Filter
Hold-up Volume < 14 µL
Housing Polypropylene
Pore Size 0.2 µm
Sample Volume < 10 mL
Separation Mode Aqueous
Solvent/Sample Compatible GHP
Units in Package 300/case

info

WAT052850 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: WAT052850

The 4 µm small particle size of Nova-Pak bonded phases offers high resolution, more efficient and faster chromatography by using shorter columns, reducing solvent consumption or by using longer columns to resolve even the most complex mixture. Semi-preparative columns with 6µm particle size packings give you an unparalleled range of separation possibilities. Stringent QC procedures in our cGMP manufacturing facility ensure batch-to-batch reproducibility.

WAT052850 - Nova-Pak C8 Cartridge, 60Å, 4 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: WAT052850
Brand: Nova-Pak

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 4
Chemistry C8
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 4 µm
Particle Substrate Silica
Pore Size 60Å
Silanol Activity Medium
Surface Area 120
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186005779 - ACQUITY UPLC HSS T3 nanoACQUITY Column 10K psi, 100Å, 1.8 µm, 100 µm X 100 mm, 1/pkg

Part Number: 186005779

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186005779 - ACQUITY UPLC HSS T3 nanoACQUITY Column 10K psi, 100Å, 1.8 µm, 100 µm X 100 mm, 1/pkg
Part Number: 186005779
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format nanoACQUITY Column 10K psi
ID 100 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186001260 - Waters PAH C18 Column, 120Å, 3 µm, 4.6 mm X 50 mm, 1/pkg

Part Number: 186001260

Polyaromatic hydrocarbons (PAHs) are among the most frequently monitored environmental contaminants. Standard and official methods for the analysis of PAHs are found in compendia for air, drinking water, wastewater, solid waste, and food analysis. Many of these methods specify HPLC, usually with UV and fluorescence detection, as the recommended analytical procedure. Introducing, from Waters Corporation, world leaders in HPLC and LCMS, the best column for HPLC analysis of PAHs, Waters PAH Column.

186001260 - Waters PAH C18 Column, 120Å, 3 µm, 4.6 mm X 50 mm, 1/pkg
Part Number: 186001260
Brand: Waters PAH

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry C18
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 120Å
Units in Package 1/pkg
pH Range 2 - 8

info

PSL613321 - PEEK STARTER KIT (NUTS/FER/FIT)

Part Number: PSL613321

By Replacing stainless steel parts such as tubings, fittings, ferrules, mobile phase filters, in-line filters, etc. you are creating a biocompatible and metallic-free environment for your samples and mobile phase. The PEEK Starter Kit is a collection of items we believe is a good start for everybody working in the field of biochromatography. Each Kit is supplied in a sturdy plastic case. The Kit contains the following items: PEEK Fingertight One-Piece (6), PEEK Handtight Nut (4), PEEK Hex-Head Nut (4), PEEK Double Ferrules (20), PEEK Tubing 1/16 x 0.25mm (1 x 3m), PEEK Tubing 1/16 x 0.50mm (1 x 3m), PEEK Union (1), Elbow 90 Degrees (2), Elbow 180 Degrees (2), Guillotine Cutter (1), PAT™ Mobile Phase Filter - Last Drop (1)

PSL613321 - PEEK STARTER KIT (NUTS/FER/FIT)
Part Number: PSL613321
Products > Chromatography Consumables & Columns > Accessories > Fittings
Category PEEK
Hardware Type Fitting
Material of Construction PEEK
Outside Diameter 1/16 in. (1.6 mm)

info

725000145 - Collection Rack, Eppendorf Tubes (120)

Part Number: 725000145

The optional Eppendorf tube rack replaces the standard tube rack. It allows collection of samples into 1.5mL Eppendorf tubes. The rack can hold 120 tubes.

725000145 - Collection Rack, Eppendorf Tubes (120)
Part Number: 725000145
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Systems Components
Products Waters Fraction Collector II
Waters Fraction Collector III
Replacement Schedule No

info

186001307 - Atlantis dc18 Column, 100Å, 3 µm, 3 mm X 150 mm, 1/pkg

Part Number: 186001307

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001307 - Atlantis dc18 Column, 100Å, 3 µm, 3 mm X 150 mm, 1/pkg
Part Number: 186001307
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186001319 - Atlantis dc18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186001319

Atlantis dC18 columns are universal, silica-based, reversed-phase C18 columns that are used for polar compound retention. The Atlantis dC18 columns feature di-functionally bonded C18 ligands that have been optimized for use with highly aqueous mobile phases, including 100% water.

186001319 - Atlantis dc18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186001319
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology dc18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 330
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 3 - 7

info

186002015 - Atlantis Silica HILIC Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: 186002015

Atlantis HILIC Silica columns are used in combination with high organic mobile phases (>80% acetonitrile) to provide retention of analytes that are simply too polar to be retained by reverse-phase chromatography. HILIC separation mechanisms provide orthogonal analyte selectivity compared to traditional chromatographic reversed-phase approaches.

186002015 - Atlantis Silica HILIC Column, 100Å, 3 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: 186002015
Brand: Atlantis

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry HILIC
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Hydrophilic Interaction (HILIC)
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 330
System HPLC
Technology Silica
USP Classification L3
Units in Package 1/pkg
pH Range 1 - 5

info

186002616 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pkg

Part Number: 186002616

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

186002616 - Symmetry C18 Column, 100Å, 5 µm, 4.6 mm X 100 mm, 1/pkg
Part Number: 186002616
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007123 - CORTECS UPLC C18 VanGuard Pre-column, 90Å, 1.6 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186007123

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007123 - CORTECS UPLC C18 VanGuard Pre-column, 90Å, 1.6 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186007123
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped No
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.6 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System UPLC/UHPLC
Technology UPLC
USP Classification L1
Units in Package 3/pkg
pH Range 2 - 8

info

186005413 - ACQUITY UPLC CSH Phenyl-Hexyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186005413

ACQUITY CSH Phenyl-Hexyl columns are used to provide alternative analyte selectivity and are a valuable tool for method development. The trifunct?ionally bonded C6 phenyl ligand is a robust, low bleed sorbents that selectively retains polyaromotic compounds through pi-pi interactions. The VanGuard pre-column connects directly to the inlet of the ACQUITY UPLC column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186005413 - ACQUITY UPLC CSH Phenyl-Hexyl VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186005413
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 14
Bonding Technology Phenyl-Hexyl
Chemistry Phenyl
Endcapped Yes
Endfitting Type Direct-Connect
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L11
Units in Package 3/pkg
pH Range 1 - 11

info

700008977 - Assy Needle 15µL w/guide and seat 18KPSI

Part Number: 700008977

ACQUITY I-Class FTN Needle Assembly, 15µL w/guide and seat 18KPSI

700008977 - Assy Needle 15µL w/guide and seat 18KPSI
Part Number: 700008977
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Needles
Product Category ACQUITY
Products ACQUITY I-Class SM-FTN
Replacement Schedule As Needed

info

WAT060328 - Bourdon Tube Transducer

Part Number: WAT060328

The transducer measures system pressure. Unlike many other parts vendors, Waters® uses only new Bourdon tube transducers and does not refurbish nor rebuild failed units. This ensures delivery of a transducer that is high in quality, reliability, and life span.

WAT060328 - Bourdon Tube Transducer
Part Number: WAT060328
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category Pumps
Products 510 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine™ Isocratic Pump

info

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg

Part Number: 186004498

Waters Protein Separation Technology (PrST) columns are QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare traditional to C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery and improve peak capacity.

186004498 - XBridge Protein BEH C4 Column, 300Å, 3.5 µm, 2.1 mm X 50 mm, 10K - 500K, 1/pkg
Part Number: 186004498
Brand: XBridge

Products > Chromatography Consumables & Columns > Columns > HPLC Columns > XBridge Columns
Application Protein
Chemistry C4
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Molecular Weight Range 10K - 500K
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Hybrid
Pore Size 300Å
QC Tested Protein
Silanol Activity Low
System HPLC
Technology BEH
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 12

info

186003542 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 75 µm X 100 mm, 1/pkg

Part Number: 186003542

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186003542 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 75 µm X 100 mm, 1/pkg
Part Number: 186003542
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format nanoACQUITY Column 10K psi
ID 75 µm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

700003530 - Solvent Filter, Titanium, 7/pkg

Part Number: 700003530

The Titanium Solvent Bottle Filters are optional for use where mobile phases contain acids.

700003530 - Solvent Filter, Titanium, 7/pkg
Part Number: 700003530
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Product Category ACQUITY
Products ACQUITY I-Class BSM
ACQUITY UPLC Binary Solvent Manager
Replacement Schedule As Needed

info

WAT011794 - DeltaPak C4 Column, 300Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: WAT011794

Delta-Pak packings, ideal for the separation of peptides, proteins, and natural products, are based on a highly stable, bonded, endcapped 5µm or 15µm spherical silica. Delta-Pak is available in two different pore sizes (100Å and 300Å) with either C4 or C18 bonded phase. Delta-Pak packings are available in different cartridge and column configurations, providing consistent and predictable scale-up capabilities for milligram-to-gram scale purification. Also, by having the same chemistry available on a high-efficiency 5µm particle, you can easily check the purity of your fractions.

WAT011794 - DeltaPak C4 Column, 300Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT011794
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 2.6
Application Protein
Chemistry C4
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 300Å
Surface Area 125
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 8

info WAT011795 - DeltaPak C18 Column, 100Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: WAT011795
Brand: DeltaPak

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Peptide Separations > Delta-Pak Columns
% Carbon Load 17
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004773 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186004773

The HSS C18 is a general-purpose C18 bonded phase column that provides superior peak shape for bases, increased retention (vs. XBridge C18 columns), and exceptional column lifetimes at low pH. The selectivity and retention observed with HSS C18 columns will resemble that of most modern, fully endcapped, high-coverage silica-based C18 columns.

186004773 - XSelect HSS C18 Column, 100Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186004773
Brand: XSelect

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 230
System HPLC
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 8

info

PSS832315 - Spherisorb Amino (NH2) Column, 80Å, 3 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: PSS832315

Spherisorb NH2 (Amino) columns contain a silica-based aminopropyl bonded sorbent. The column is listed as USP L8 and is used for anion-exchange, normal-phase and HILIC separations.

PSS832315 - Spherisorb Amino (NH2) Column, 80Å, 3 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: PSS832315
Brand: Spherisorb

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 1.9
Chemistry Amino (NH2)
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3 µm
Particle Substrate Silica
Pore Size 80Å
Surface Area 220
System HPLC
USP Classification L8
Units in Package 1/pkg
pH Range 2 - 8

info

700003276 - Q-Tof Qualification Standards Kit

Part Number: 700003276

Mass Spectrometry (QToF) standards kit for system assessment. 11 Components: 1. 2 x Vials Leucine Enkephalin 3 mg ±0.15 mg 12 mL Amber Screw top Vial 2. 1 x 25mL Sodium Iodide 25mL 2 µg/µL in 50:50 2-Propanol: Water 30 mL Clear Nalgene Bottle 3. 1 x 12mL Bovine Insulin 3 mg ±0.15 mg 12 mL Amber Screw-top Vial 4. 2 x 15mL Horse Heart Myoglobin 2.5 mg ±0.125 mg 15 mL Clear Nalgene Bottle 5. 2 x 15mL D(+)-Raffinose 2.5 mg ±0.125 mg 15 mL Clear Nalgene Bottle 6. 2 x 4mL [Glu1]-Fibrinopeptide B 0.1 mg ±0.01 mg 4 mL Amber Screw top Vial 7. 1 x 4mL Sodium Hydroxide 2mL 0.1M in Water 4 mL Clear Nalgene Bottle 8. 1x 15mL Haemoglobin (Human) 2.52 mg ±0.125 mg 15 mL Clear Nalgene Bottle 9. 5 x Vials ? - Cyano-4-hydroxycinnamic acid* 10 mg ±0.1 mg Each vial in a sealed foil bag Matrix 10. 1 x 2mL PEG Mix** 2mL 50:50 Acetonitrile: Water +0.2 % Formic 2mL Amber Flame-sealed Ampule w/ cracker PEG Ready Mixed Solution 11. 1 x 2mL PEG Maldi*** 10 mg/mL 50:50 Acetonitrile: Water 2mL Amber Flame-sealed Ampule w/ cracker PEG Maldi Ready Mixed Solution Certificate of Analysis

700003276 - Q-Tof Qualification Standards Kit
Part Number: 700003276
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents
Applications Instrument Performance
Detector Mass Spec
Product Type Standard
Shipping Formulation Liquid
Storage Frozen -20 C
System LC/MS