Product Listing:  186007367 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg   to   WAT106157 - Symmetry C18 Column, 300Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Sorted by Popularity
  Product    
info

186007367 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg

Part Number: 186007367

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007367 - CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 100 mm, 1/pkg
Part Number: 186007367
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 2.1 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007372 - CORTECS C18 Column, 90Å, 2.7 µm, 3 mm X 100 mm, 1/pkg

Part Number: 186007372

CORTECS C18 Columns are general purpose, high-efficiency columns based on a solid-core particle that offer balanced retention of acids, bases and neutrals at low and mid-range pH.

186007372 - CORTECS C18 Column, 90Å, 2.7 µm, 3 mm X 100 mm, 1/pkg
Part Number: 186007372
Brand: CORTECS

Products > Chromatography Consumables & Columns
% Carbon Load 6.6
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 3 mm
Length (mm) 100 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 2.7 µm
Particle Substrate Solid-Core
Pore Size 90Å
Silanol Activity Low
Surface Area 100
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT011690 - Free Fatty Acid HP Column, 4 µm, 3.9 x 150 mm

Part Number: WAT011690

The Free Fatty Acid HP column uses a phenyl-bonded packing to separate free fatty acids based on carbon chain length and degree of saturation.

WAT011690 - Free Fatty Acid HP Column, 4 µm, 3.9 x 150 mm
Part Number: WAT011690
Brand: Free Fatty Acid HP

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Size (dp) 4 µm
Pore Size 60Å
USP Classification L1
Units in Package 1/pkg

info

WAT094269 - Symmetry Shield RP 8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT094269

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP8 column significantly improves peak shape and resolution.

WAT094269 - Symmetry Shield RP 8 Column, 100Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT094269
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

700002594 - Transducer Assy, Head Mounted, 15K PSI

Part Number: 700002594

This spare part is a Waters Quality part.

700002594 - Transducer Assy, Head Mounted, 15K PSI
Part Number: 700002594
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Mechanical
Product Category ACQUITY
nanoACQUITY
Products ACQUITY H-Class Quaternary Solvent Manager
ACQUITY UPLC Binary Solvent Manager
nanoACQUITY UPLC Binary Solvent Manager/Auxiliary Solvent Manager
Replacement Schedule As Needed

info

WAT045559 - Seal Pack and Needle Replacement Kit

Part Number: WAT045559

The Seal Pack and Needle Replacement Kit contains the following parts: one stainless steel annealed ferrule, one short compression screw (for old style injector only), one needle, one long compression screw (for new style injector only), one seal pak assembly, and the installation instructions.

WAT045559 - Seal Pack and Needle Replacement Kit
Part Number: WAT045559
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Injectors
Product Category Injectors
Systems
Products LC Module 1

info

186005964 - ACQUITY UPLC HSS PFP Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 1/pkg

Part Number: 186005964

ACQUITY UPLC HSS PFP is a non-endcapped silica-based column designed for low pH separations that require alternative selectivity compared to a fully endcapped, high coverage C18 phase. ACQUITY HSS PFP columns are fully scalable and transferable to HPLC separations.

186005964 - ACQUITY UPLC HSS PFP Column, 100Å, 1.8 µm, 2.1 mm X 30 mm, 1/pkg
Part Number: 186005964
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 7
Bonding Technology PFP
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 30 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L43
Units in Package 1/pkg
pH Range 2 - 8

info

186005965 - ACQUITY UPLC HSS PFP Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pkg

Part Number: 186005965

ACQUITY UPLC HSS PFP is a non-endcapped silica-based column designed for low pH separations that require alternative selectivity compared to a fully endcapped, high coverage C18 phase. ACQUITY HSS PFP columns are fully scalable and transferable to HPLC separations.

186005965 - ACQUITY UPLC HSS PFP Column, 100Å, 1.8 µm, 2.1 mm X 50 mm, 1/pkg
Part Number: 186005965
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 7
Bonding Technology PFP
Chemistry PFP / Fluoro-Phenyl
Endcapped No
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 230
System UPLC/UHPLC
Technology HSS
USP Classification L43
Units in Package 1/pkg
pH Range 2 - 8

info

186000491 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000491

XTerra MS C8 columns are general purpose, hybrid-based, reversed-phase C8 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000491 - XTerra MS C8 Column, 125Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000491
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 12
Bonding Technology MS C8
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 1 - 12

info

186003544 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pkg

Part Number: 186003544

nanoACQUITY Ultra Performance LC™ Columns are designed for optimal performance for capillary to nano-scale liquid chromatographic separation, offering the highest possibile sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. These columns are specifically designed for use with the Waters nanoACQUITY UPLC™ System. Since 2004, Waters has increased the operating pressure of the nanoACQUITY UPLC™ System to 10,000PSI, requiring the development of new columns specifically designed for use on this upgraded system (Columns rated at 10kpsi). These columns are available from several proven column chemisitries including Symmetry C18, Atlantis dC18, and the Peptide Separation Technology columns which incorporate the 1.7µm BEH130 material.

186003544 - ACQUITY UPLC Peptide BEH C18 nanoACQUITY Column 10K psi, 130Å, 1.7 µm, 75 µm X 200 mm, 1/pkg
Part Number: 186003544
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > Nano and Micro LC Columns > nanoACQUITY UPLC Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Format nanoACQUITY Column 10K psi
ID 75 µm
Length (mm) 200 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186007474 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 75 µm X 250 mm, 1/pkg

Part Number: 186007474

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007474 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 75 µm X 250 mm, 1/pkg
Part Number: 186007474
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186007484 - ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pkg

Part Number: 186007484

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007484 - ACQUITY UPLC M-Class Peptide BEH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pkg
Part Number: 186007484
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

186007478 - ACQUITY UPLC M-Class Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pkg

Part Number: 186007478

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007478 - ACQUITY UPLC M-Class Peptide CSH C18 Column, 130Å, 1.7 µm, 75 µm X 250 mm, 1/pkg
Part Number: 186007478
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type 10-32 for 1/16" male /360um open
Format Column
ID 75 µm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology CSH
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 10

info

WAT035711 - Polyethylene Glycol Standards Kit

Part Number: WAT035711

A unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for aqueous molecular weight determination. Polyethylene Glycol Standards Kit 10 Vials, 1.0g in each vial containing the following moleculare weight standards: 100, 200, 400, 600, 1000, 1500, 4300, 7000, 13000, 22000

WAT035711 - Polyethylene Glycol Standards Kit
Part Number: WAT035711
Products > Chromatography Consumables & Columns > Analytical Standards and Reagents > Chemical and Environmental Analysis Standards > GPC & GFC Standards
Applications Life Science
Detector UV
Product Type Standard
Shipping Formulation Solid
Storage Refrigerator 2 to 8 C
System HPLC -UV

info

186003454 - SunFire Silica Prep Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186003454

SunFire Prep Silica columns are general purpose columns used under normal phase conditions.

186003454 - SunFire Silica Prep Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186003454
Brand: SunFire

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
Chemistry Silica
Endcapped No
Endfitting Type Waters
Format Prep Column
ID 4.6 mm
Length (mm) 250 mm
Mode Normal-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System HPLC
USP Classification L3
Units in Package 1/pkg
pH Range 2 - 8

info

186007472 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pkg

Part Number: 186007472

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007472 - ACQUITY UPLC M-Class HSS T3 Column, 1.8 µm, 300 µm X 150 mm, 1/pkg
Part Number: 186007472
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 11
Bonding Technology T3
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Column
ID 300 µm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.8 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Medium
Surface Area 230
System Nano/Micro
Technology HSS
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054200 - Symmetry C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: WAT054200

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054200 - Symmetry C18 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: WAT054200
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186000113 - Symmetry Shield RP18 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186000113

These reversed-phase columns contain Waters patented embedded polar group technology that “shields” the silica’ residual silanol surface from highly basic analytes. The reduced silanol activity for the SymmetryShield RP18 column significantly improves peak shape and resolution. This product needs to be used in conjunction with other parts. Please see the section below on related parts for more information

186000113 - Symmetry Shield RP18 Cartridge, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186000113
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 17
Bonding Technology Shield RP18
Chemistry C18
Endcapped Yes
Format Cartridge
ID 4.6 mm
Length (mm) 250 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

WAT054230 - Symmetry C8 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg

Part Number: WAT054230

Symmetry C8 columns feature monofunctionally bonded C8 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT054230 - Symmetry C8 Column, 100Å, 5 µm, 3 mm X 150 mm, 1/pkg
Part Number: WAT054230
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 11.7
Chemistry C8
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L7
Units in Package 1/pkg
pH Range 2 - 8

info

186000478 - XTerra MS C18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg

Part Number: 186000478

XTerra MS C18 columns are general purpose, hybrid-based, reversed-phase C18 columns that are designed to be compatible with mass spectrometry applications. These first generation columns provide superior pH stability compared to a silica-based column.

186000478 - XTerra MS C18 Column, 125Å, 5 µm, 3.9 mm X 150 mm, 1/pkg
Part Number: 186000478
Brand: XTerra

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 15.5
Bonding Technology MS C18
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 3.9 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 125Å
Silanol Activity Low
Surface Area 175
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

186007471 - ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pkg

Part Number: 186007471

ACQUITY UPLC M-Class Columns are designed for optimal performance for nano- to micro scale liquid chromatographic separation, offering the highest possible sensitivity, resolution and reproducibility for biomarker discovery and protein identification and characterization. The 300µm ID columns are built utilizing a ultra low dispersion column design and offer the same simplicity of use as more traditional columns. Like all M-Class columns they withstand 15kpsi operating pressure and handle pressure fluctuations during injection extremely well and thus provide superior longevity. In order to achieve maximum performance, it is important to ensure that proper connections are made to minimize peak tailing and poor efficiency. This specific offering contains Waters patented BEH Technology 130A pore, C18, 1.7um particles. Each batch is specifically QC tested using a gradient separation of a tryptic digest of cytochrome c to before being QC accepted as a Peptide separation column.

186007471 - ACQUITY UPLC M-Class Peptide BEH C18 Trap Column, 130Å, 5 µm, 300 µm x 50 mm, 1/pkg
Part Number: 186007471
Brand: ACQUITY UPLC M-Class

Products > Chromatography Consumables & Columns > Columns
% Carbon Load 18
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Parker-style
Format Trap Column
ID 300 µm
Length (mm) 50 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System Nano/Micro
Technology BEH
USP Classification L1
Units in Package 1/pkg
pH Range 1 - 12

info

201000178 - MALDI TOF PERFORMANCE MAINTENANCE

Part Number: 201000178

The Waters® Performance Maintenance Kit for the MALDI micro MX ,MALDI LR, MALDI L, and MALDI R Mass Spectrometers contains all the Waters Quality Parts® necessary to keep yourinstrument operating at peak performance on an annual basis. The Waters® Performance Maintenance Kitincludes the following parts: Source component and vacuum pump components.

201000178 - MALDI TOF PERFORMANCE MAINTENANCE
Part Number: 201000178
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit Yes
Part Category PM Kits
Product Category Mass Spectrometry
Products MALDI LR Mass Spectometer
MALDI micro MX Mass Spectrometer
Replacement Schedule Annually

info

WAT056975 - Symmetry C18 Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pkg

Part Number: WAT056975

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

WAT056975 - Symmetry C18 Column, 100Å, 5 µm, 2.1 mm X 150 mm, 1/pkg
Part Number: WAT056975
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 19.1
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 2.1 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity Low
Surface Area 335
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8

info

186004911 - Viridis Silica Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg

Part Number: 186004911

Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level of reproducibility to the world of laboratory scale purification. Viridis SFC columns are available for analytical and preparative chromatography as Viridis SFC 2-Ethylpyridine columns and Viridis SFC Silica columns. Larger preparative column formats are manufactured using Waters patented Optimum Bed Density (OBD) Technology. 2-Ethylpyridine chemistry is successfully used for a wide range of achiral SFC applications due to its retention, peak shape and selectivity properties. Viridis SFC 2-ethylpyridine columns also provide high reliability and reproducibility and can be used for analytical and preparative applications. Based on Waters long history of chromatographic silica production, the Viridis SFC Silica columns are designed to be highly reproducible and predictable based on tight product specifications and very low metal content.

186004911 - Viridis Silica Column, 100Å, 5 µm, 4.6 mm X 250 mm, 1/pkg
Part Number: 186004911
Brand: Viridis

Products > Chromatography Consumables & Columns > Columns > SFC Columns
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 250 mm
Mode SuperCritical Fluid (SFC)
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 100Å
Silanol Activity High
Surface Area 340
System UPC2/SFC
Technology Silica
Units in Package 1/pkg

info

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg

Part Number: 186006939

Waters ACQUITY UPLC CSH130 C18 1.7 µm particles contain a low and carefully-defined concentration of positive charges that yield comparatively excellent peak shape for peptides using either FA- or TFA-containing mobile phases. The fact that the performance of a CSH130 C18 column exhibits little dependence on strong ion pairing agents makes it ideal for LC or LC-MS applications. The VanGuard pre-column connects directly to the inlet of an eXtended Performance column which minimizes extra columns volumes and reduces leaking by eliminating additional connections.

186006939 - ACQUITY UPLC Peptide CSH C18 VanGuard Pre-column, 130Å, 1.7 µm, 2.1 mm X 5 mm, 3/pkg
Part Number: 186006939
Brand: ACQUITY UPLC

Products > Chromatography Consumables & Columns > Columns > UPLC Columns > ACQUITY UPLC Columns
% Carbon Load 15
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format VanGuard Pre-column
ID 2.1 mm
Length (mm) 5 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 130Å
QC Tested Peptide
Silanol Activity Low
Surface Area 185
System UPLC/UHPLC
Technology CSH
USP Classification L1
Units in Package 3/pkg
pH Range 1 - 11

info

186000283 - Symmetry C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: 186000283

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

186000283 - Symmetry C4 Column, 300Å, 3.5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: 186000283
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > HPLC Columns
% Carbon Load 2.8
Application Protein
Chemistry C4
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 3.5 µm
Particle Substrate Silica
Pore Size 300Å
Silanol Activity Low
Surface Area 110
System HPLC
USP Classification L26
Units in Package 1/pkg
pH Range 2 - 8

info

186006992 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 30 mm, 1/pkg

Part Number: 186006992

ACQUITY APC XT columns are optimized to provide highly efficient size-based separations for organic solvent soluble polymer characterization. The sorbent uses patented Ethylene Bridge Hybrid (BEH) technology to provide a mechanical strong packed bed that resists shinking and swelling for easy mobile phase solvent switching.The expected molecular weight range for this column is approximatley 200 - 5, 000 g/mole.

186006992 - ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 30 mm, 1/pkg
Part Number: 186006992
Brand: ACQUITY APC

Products > Chromatography Consumables & Columns > Columns > ACQUITY APC Columns
Chemistry XT - Extended Temperature
Endcapped No
Endfitting Type Parker-style
Format Column
ID 4.6 mm
Length (mm) 30 mm
Mode SEC/GPC
Particle Shape Spherical
Particle Size (dp) 1.7 µm
Particle Substrate Hybrid
Pore Size 45Å
Silanol Activity Low
System APC
Units in Package 1/pkg
pH Range 1 - 12

info

205000329 - Alliance Bottle Tray Kit

Part Number: 205000329

A larger capacity solvent tray is now used on all the Separations Modules as an option. This new tray relocates the detector directly above the column heater or column heater/cooler thus minimizing ambient temperature effects upon column to detector flow cell tubing. It also creates more space for larger solvent bottles. This change also enhances the routing of solvent and wash line tubings from the top of the system down into the module.

205000329 - Alliance Bottle Tray Kit
Part Number: 205000329
Services & Support > Spare Parts > Spare Parts Catalog
PM Kit No
Part Category Accessories
Product Category Separations Module
Products 2695 Separations Module
2695D Dissolution Separations Module
2795 Separations Module
2796 Bioseparations Module
Replacement Schedule As Needed

info

WAT021906 - AP-1 Glass Column, 10x600 mm, 1/pkg

Part Number: WAT021906

Waters Advanced Purification (AP) glass columns are constructed of biocompatible glass and polymeric materials for use with silica, polymer, or soft gel packings.

WAT021906 - AP-1 Glass Column, 10x600 mm, 1/pkg
Part Number: WAT021906
Brand: Advanced Purification

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > MS and LC-MS Consumables for Biomolecules
Application Protein
Endfitting Type Waters
Format AP Glass Column
ID 10 mm
Length (mm) 600 mm
Units in Package 1/pkg

info

WAT106157 - Symmetry C18 Column, 300Å, 5 µm, 4.6 mm X 150 mm, 1/pkg

Part Number: WAT106157

Symmetry columns continues to set the standard for HPLC drug assays, giving you confidence in the long-term compliance of your HPLC methods. No need to compromise on peak shape, selectivity, column-to-column and batch-to-batch reproducibility, or other critical performance characteristics. Available in a variety of particle sizes, chemistries and dimensions.

WAT106157 - Symmetry C18 Column, 300Å, 5 µm, 4.6 mm X 150 mm, 1/pkg
Part Number: WAT106157
Brand: Symmetry

Products > Chromatography Consumables & Columns > Columns > Bioseparations Columns & Consumables > Protein Separations > Symmetry300 Columns
% Carbon Load 8.5
Application Peptide
Chemistry C18
Endcapped Yes
Endfitting Type Waters
Format Column
ID 4.6 mm
Length (mm) 150 mm
Mode Reversed-Phase
Particle Shape Spherical
Particle Size (dp) 5 µm
Particle Substrate Silica
Pore Size 300Å
Silanol Activity Low
Surface Area 110
System HPLC
USP Classification L1
Units in Package 1/pkg
pH Range 2 - 8